• Title/Summary/Keyword: Parallel Rig

Search Result 14, Processing Time 0.021 seconds

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount (냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Yu, Tae-Guen;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.

Study of perception of the visual depth caused by the color correction (입체영상 제작에서 색 보정 결과가 입체감 인지에 미치는 영향 연구)

  • Han, Myung-Hee;Kim, Chee-Yong
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.177-184
    • /
    • 2010
  • These days, as digital producing technique has been developed, 3D imaging technique is used in high-tech computer and T.V. Also study for 3D producing technique is actively in progress. Moreover, as James Cameron's movie, 'Avatar' released in 2009 was a box office hit, the issue about 3D image came to the fore again. At this point, I decided to study the effect of the visual depth caused by the color correction during the post-production stage. The purpose of this study is to offer information about processing effective images through data about the effect of the visual depth that applies the color correction during the post-production stage. Basically, I supposed that color and contract would have effects on depth of 3D image. As a result, I could find out the changes of visual depth, space perception and sense of depth throughout the experiment. Applying this result,, I produced the 15 minutes of 3D advertisement movie and I found out that the color correction during the post-production stage was very effective for 3D depth. The left image and the right image by beam splitter based rig and parallel rig were used for this study. Also I adjusted the strong contrast by the color correction during the post-production stage after correcting convergence and visual depth during editing. As a result, I could produce images which had strong sense of space and sense of depth.

Experimental Study on the Characteristics of Misaligned Self-equalizing Tilting Pad Thrust Bearing (자려 평형 틸팅 패드 스러스트 베어링의 정렬불량에 따른 베어링 특성에 관한 실험적 연구)

  • Song, AeHee;Jo, HyunJun;Choi, SeongPil;Kim, SeonJin
    • Tribology and Lubricants
    • /
    • v.36 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • Self-equalizing tilting pad thrust bearings are usually employed in turbomachines to achieve high stability and reliability. A tilting pad bearing can incorporate self-equalizing links to handle the misalignment between the bearing and the thrust collar. In this popular design method, the pads sit on the upper-level plates and the lower-level plates stay on the retainer base. With misalignment, the pads that are heavily loaded are pushed down. Consequently, the link pushes up the pads on the opposite side, keeping the bearing surface parallel to the thrust collar surface. The self-equalizing link is used to handle the misalignment from the thermal and mechanical effects. In this study, the experimental investigation deals with the performance of self-equalizing tilting pad thrust bearings. The test rig for evaluating the performance of bearing is developed which can control the misalignment angle. Simultaneous measurements are taken for the force acting on each pad. Pad metal temperature and oil film thickness are functions of the shaft speed, bearing load, misalignment angle, and design of leveling plates. The effect of misalignment on bearing performance is discussed. The results demonstrate that the load on each pad depends on the test conditions(especially misalignment angle), and the load influences the performance of bearings.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.