• Title/Summary/Keyword: Parallel Resonance

Search Result 232, Processing Time 0.269 seconds

Loads of a Rigid Link Connecting a Container Ship and a Catamaran Type Container Offloading Vessel in Waves (파랑중 컨테이너선과 하역선의 연결장치에 작용하는 하중계산)

  • Hong, Do-Chun;Kim, Yong-Yook;Han, Soon-Hung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • The hydrodynamic interaction of two floating bodies in waves freely floating or connected by a rigid link is studied by using a boundary element method in the frequency-domain. The exact two-body hydrodynamic coefficients of added mass, wave damping and exciting force are calculated from the radiation-diffraction potential solution of the improved Green integral equation associated with the free surface Green function. The irregular frequencies in the conventional Green integral equation make it difficult to predict the physical resonance of the fluid in the gap between two bodies floating side by side. However, the improved Green integral equation employed in this study is free of irregular frequencies and always yields the exact solution of the multi-body radiation-diffraction potential boundary value problem. The 6 degree-of-freedom motions of two bodies freely floating side by side or connected parallel by a rigid link have been calculated for the incident wave frequencies ranging from 0.1 to 5 radians per second in head, left and right bow quartering seas. The 6-component load of the rigid link have also been presented.

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

A study on the Cochlear View in Multichannel Cochlear Implantees (인공와우 이식술 환자의 Cochlear View 촬영에 관한 연구)

  • Kweon, Dae-Cheol;Kim, Jeong-Hee;Kim, Seong-Lyong;Kim, Hae-Seong;Lee, Yong-Woo
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.27-32
    • /
    • 1999
  • Cochlear implant poses a contraindication to the magnetic resonance imaging(MRI) process, because MRI generates artifacts, inducing an electrical current and causing device magnetization. CT is relatively expensive and the metal electrodes scatter the image. Post-implantation radiological studies using anterior-posterior transorbital, submental-vertex and lateral views, the intracochlear electrodes are not well displayed. Therefore, the authors developed a special view, which we call the cochlear view. The patient is sitting in front of a vertical device. Then the midsagittal plane is adjusted to form an angle of $15^{\circ},\;30^{\circ}$, and $45^{\circ}$ with the film. The flexion of the neck is adjusted to make the infraorbitomeatal line(IOML) is parallel with the transverse axis of the film. The central ray is directed to exit from the skull at point which is 3.0 cm anterior and 2.0 cm superior to the EAM(external auditory meatus). Results have shown that single radiography of the cochlear view provides sufficient information to demonstrate the position of the electrodes array and the depth of insertion in cochlear. Radiography of the cochlear view in angle of $45^{\circ}$ is an excellent image. The cochlear view gives the greatest amount of medical information with the least radiation and lowest medical cost. It can be widely used in all cochlear implant clinics.

  • PDF

Implementation of High-Quality Si Integrated Passive Devices using Thick Oxidation/Cu-BCB Process and Their RF Performance (실리콘 산화후막 공정과 Cu-BCB 공정을 이용한 고성능 수동 집적회로의 구현과 성능 측정)

  • 김동욱;정인호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.509-516
    • /
    • 2004
  • High-performance Si integrated passive process was developed using thick oxidation process and Cu-BCB process. This passive process leads to low-cost and high-quality RF module with a small form factor. The fabricated spiral inductor with 225 um inner diameter and 2.5 turns showed the inductance of 2.7 nH and the quality factor more than 30 in the frequency region of 1 ㎓ and above. Also WLCSP-type integrated passive devices were fabricated using the high-performance spiral inductors. The fabricated low pass filter had a parallel-resonance circuit inside the spiral inductor to suppress 2nd harmonics and showed about 0.5 ㏈ insertion loss at 2.45 ㎓. And also the high/low-pass balun had the insertion loss less than 0.5 ㏈ and the phase difference of 182 degrees at 2.45 ㎓.

Recent advances in the characterization and the treatment methods of effluent organic matter

  • Ray, Schindra Kumar;Truong, Hai Bang;Arshad, Zeshan;Shin, Hyun Sang;Hur, Jin
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.257-274
    • /
    • 2020
  • There are many previous review articles are available to summarize either the characterization methods of effluent organic matter (EfOM) or the individual control treatment options. However, there has been no attempt made to compare in parallel the physicochemical treatment options that target the removal of EfOM from biological treatments. This review deals with the recent progress on the characterization of EfOM and the novel technologies developed for EfOM treatment. Based on the publications after 2010, the advantages and the limitations of several popularly used analytical tools are discussed for EfOM characterization, which include UV-visible and fluorescence spectroscopy, Fourier transform infrared spectroscopy (FTIR), size exclusion chromatography (SEC), and Fourier transform-ion cyclotron resonance-mass spectrometry (FT-ICR-MS). It is a recent trend to combine an SEC system with various types of detectors, because it can successfully track the chemical/functional composition of EfOM, which varies across a continuum of different molecular sizes. FT-ICR-MS is the most powerful tool to detect EfOM at molecular levels. However, it is noted that this method has rarely been utilized to understand the changes of EfOM in pre-treatment or post-treatment systems. Although membrane filtration is still the preferred method to treat EfOM before its discharge due to its high separation selectivity, the minimum requirements for additional chemicals, the ease of scaling up, and the continuous operation, recent advances in ion exchange and advanced oxidation processes are greatly noteworthy. Recent progress in the non-membrane technologies, which are based on novel materials, are expected to enhance the removal efficiency of EfOM and even make it feasible to selectively remove undesirable fractions/compounds from bulk EfOM.

Wireless Power Transmission Technology for Implantable Telemetry Device based on Multiple Transmit Coils (다중코일방식에 기초한 원격 생체 정보 측정을 위한 무선전력전송 기술)

  • Ryu, Young-Kee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.203-211
    • /
    • 2015
  • The implanted telemetry system provides the monitoring of species while they move within their cages. Species monitored include mice, rats, rabbits, dogs, pigs, primates, sheep, horses, cattle, and others. A miniature transmitter implanted in each animal measures one or more parameters. Parameters measured include arterial pressure, intra-pleural pressure, left ventricular pressure, intra-ocular pressure, bladder pressure, ECG, EMG, EEG, EOG, temperature, activity, and other parameters and transmits the data via radio frequency signals to a nearby receiver. Every conventional dedicated transmitter contains one or more sensors, cpu and battery. Due to the expected life of battery, the measuring time is limited. To overcome these problems, electromagnetic inductive coupling based wireless power transmission technology using multiple transmit coils were proposed. Each coil having different active area are driven by the coil driver. In this research, parallel resonance based coil driver was proposed. In addition, the device to detect where the receiver is positioned was proposed. From the experiments we show how to determine the driving condition of coil driver.

Miniaturization and Rejection-Enhancement of the Bandpass Filter for the T-DMB Application Using a Metamaterial Structure of the Zero-Order Resonator Coupling (Zero-Order Resonator 결합의 Metamaterial 구조를 응용한 T-DMB 대역 통과 여파기의 소형화와 차단 대역 특성의 개선)

  • Shin, Un-Chul;Kahng, Sung-Tek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1462-1469
    • /
    • 2008
  • This paper proposes the design method based on the Composite Right/Left-Handed(CRLH) structure to miniaturize and enhance the rejection performance in the stopband of the bandpass filter for a VHF band($169{\sim}211\;MHz$). For realization, we used the 0-th order resonance point of the CRLH and the simple theory of Inverter as coupling. The proposed technique is validated by the performance predictions and experiments, (Insertion loss <2 dB, $S_{11}$< -15 dB, suppression of up to the 3rd harmonic) and it is found out that the suggested method enables the size reduction of around 60 % from the conventional filters such as the parallel edge coupled type.

Insertion Loss Characteristics of a Parallel Two-Wire Transmission Line with Equal Line Length Due to a Rectangular Aperture Sizes in Dual Ground Planes (두 개의 접지 평판 사각형 개구의 변화에 따른 평행 2선 전송 선로의 삽입 손실 특성)

  • Jung, Sung-Woo;Lim, Sung-Min;Jin, Jung-Hi;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.675-682
    • /
    • 2011
  • This paper presents two ground plane effects due to the size of two rectangular apertures for two-wire transmission line with equal line length crossing the changeable rectangular apertures in infinite ground planes. The CST MWS is used to determine the characteristics of the insertion loss of the transmission line from the load section in accordance with the ground plane aperture size. The results show that the insertion gain and the insertion loss are periodically observed for the multiple frequency of the half wavelength resonance by the wire length when the transmission line is nearby to horizontal side or vertical side of the aperture. The measurements of the insertion loss are performed to verify the theoretical analysis.

Design and Implementation of Enhanced Resonant Converter for EV Fast Charger

  • Ahn, Suk-Ho;Gong, Ji-Woong;Jang, Sung-Roc;Ryoo, Hong-Je;Kim, Duk-Heon
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.143-153
    • /
    • 2014
  • This paper presents a novel application of LCC resonant converter for 60kW EV fast charger and describes development of the high efficiency 60kW EV fast charger. The proposed converter has the advantage of improving the system efficiency especially at the rated load condition because it can reduce the conduction loss by improving the resonance current shape as well as the switching loss by increasing lossless snubber capacitance. Additionally, the simple gate driver circuit suitable for proposed topology is designed. Distinctive features of the proposed converter were analyzed depending on the operation modes and detail design procedure of the 10kW EV fast charger converter module using proposed converter topology were described. The proposed converter and the gate driver were identified through PSpice simulation. The 60kW EV fast charger which generates output voltage ranges from 50V to 500V and maximum 150A of output currents using six parallel operated 10kW converter modules were designed and implemented. Using 60kW fast charger, the charging experiments for three types of high-capacity batteries were performed which have a different charging voltage and current. From the simulation and experimental results, it is verified that the proposed converter topology can be effectively used as main converter topology for EV fast charger.

The Design of 800MHz Band Repeater Antenna for Ship Base Station Application (선박기지국 응용을 위한 800MHz 대역 중계기용 안테나 설계)

  • Kim, Kab-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.3
    • /
    • pp.219-222
    • /
    • 2007
  • In this paper, we have designed microstrip antenna of 800[MHz] band. It will be able to integrate TRS(Trunked Radio System), GSM(Global System for Mobile telecommunication) band including the CDMA(Code Division Multiple Access) band. we designed repeater and a base station antenna which is possible at the ship and marine of safety. It is improves a narrow bandwidth problem of microstrip antenna. It had L-shaped feeding structure at a rectangular patch and added the parallel L-slot that used a duplex resonance effect. Also for the improvement of profit the stack with the perpendicular. Designed frequency bandwith(VSWR 2:1) of the antenna showed good characteristic of 789${\sim}$1046[MHz] to 292[MHz](36%). Also the E-plan and H-plan all profit 6.4[dBi] above, the 3[dB] beam width showed the characteristic over the E-plan $44.7^{\circ} and H-plan $61.8^{\circ} to be improved.

  • PDF