Formation of a paraffin slurry and its convective heat transfer in a circular pipe (파라핀 슬러리의 생성 및 관내 대류열전달에 관한 연구)

  • Choe, Eun-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.50-60
    • /
    • 1998
  • As a method to develop an enhanced heat transfer fluid, the fine particles of a phase-change material were mixed with a conventional heat transfer fluid. Paraffin, which can be obtained easily in domestic market, was used for the phase-change material and water was used as a carrier fluid. Fine liquid particles of paraffin were formed in water as an emulsion by using an emulsifier, and they were cooled rapidly to become solid particle, resulting in paraffin slurry. The average diameter of produced solid particles was inversely proportional to the amount of the added emulsifier, which was theoretically proved. The produced paraffin slurry was tested thermally in heat transfer test section having a constant-heat-flux boundary condition. The test section was made of a circular stainless-steel pipe, which was directly heated by the power supply having a maximum of 50 Volts-500 Amperes. DSC(Differential scanning calorimeter) tests showed that two kinds of phase change were involved in the melting of paraffin, and it was explained in two different ways. A five- region-melting model was developed by extending the conventional three-region-melting model, and was used to obtain the local bulk mean temperatures of paraffin slurry in the heating test section. The local heat transfer coefficient showed a maximum where the bulk mean temperature of the paraffin slurry reached at the melting temperature of paraffin.

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF

Fundamental Study on the Solidification of Sewage Sludge by Paraffin Binder (파라핀 고화제를 이용한 하수 슬러지 고화처리를 위한 기본 연구)

  • 정하익;조진우;임재상;김상길
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.443-446
    • /
    • 2000
  • The feasibility study on paraffin binder as a solidifying agent of digested sewage sludge cake was peformed. The availability of paraffin binder as a solidifying agent was investigated by several tests. Based on the tests, it is ascertained that paraffin binder with a small amount of quicklime and fly ash enhances the solidification of digested sewage sludge cake. Paraffin binder shortened the drying time of digested sewage sludge cake and solidified sludge with paraffin was not dissolved in water again. Also, the unconfined compressive strength of solidified sludge with paraffin increases.

  • PDF

A study on the Effectivness of Hand-made Paraffin Thyroid Phantom (Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구)

  • Park, Soung-Ock;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Phantoms are very necessary for quality assurance of radio nuclides imaging systems to maintain standards and to ensure reproducibility of test. General quality assurance and instrument quality control are essential in every hospital. The human tissue equivalent materials are aluminum, areryl, water and epoxy..etc. It is very important to select optimum equivalant materials for a phantoms in QC. Especially, paraffin is very similar with human soft tissue in X or Gamma-ray physical characteristics and easy to buy with economically. We made a paraffin thyroid phantom and compare with thyroid areryl phantom, also used commercially in practice. Two small size cold spots(3 and 6 mm diameter) and a hot spot(3 mm diameter) embeded in paraffin phantom. And imaged with $^{99m}TcO_4$ by camera for analysis about spatial resolution and noise at the hot and cold spots. We got some results as below : 1. No difference in counting rate and noise between both arcryl and paraffin thyroid phantoms. 2. The best spatial resolution can be seen 6 cm distance between pinhole collimator and thyroid phantoms(arcryl and paraffin). 3. More optimal spatial resolution could acquired in paraffin thyroid phantom. Paraffin is very similar with human soft tissue in atomic number, density and relative absorbtion function, and can be shaped easily what we wanted. So we can recommendation paraffin as quality assurance phantom because its usefulness, economical benefit and purchasability.

  • PDF

[Retracted]The effect of Massage and Paraffin on Cold Hypersensitivity Patient ([논문표절]수족냉증에 적용한 마사지와 파라핀의 효과)

  • Roh, Hyo-lyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.101-102
    • /
    • 2017
  • This study of purpose was to evaluate the changes in hands and feet temperature by applying massage and paraffin bath.. The subject of this study was 30 university healthy students. Subjects were divided into paraffin bath group and massages group. The digital infrared thermographic imaging was used for thermographic analysis. The visual analog scale was used for subjective information about the degree of cold sensitivity and cold stress test was used for analyzing the temperature recovery rate. After the interventions showed that temperature difference of the right hand and temperature difference of the left hand are less in the paraffin group than the massage group. When applied paraffin bath and massage to the cold hypersensitivity patient the massage group showed difference in the visual analog scale and the paraffin group showed difference in the temperature of the right hand, left hand, left foot and in the visual analog scale. Paraffin bath treatment seems to be useful to patients with cold hypersensitivity on hands and feet.

Study on the cooling performance of discrete heat sources using coolants (냉각제들에 따른 불연속 발열체의 냉각성능 연구)

  • 최민구;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.224-235
    • /
    • 1999
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water, PF-5060, and paraffin slurry. The experimental parameters were coolants including Paraffin slurry with mass fraction of 2.5~7.5%, heat flux of 10~40W/$\textrm{cm}^2$ for the simulated VLSI chips and Reynolds numbers of 3,000~20,000. The size of paraffin slurry was constant as 10~40${\mu}{\textrm}{m}$ before and after the experiment. The chip surface temperatures for paraffin slurry were lower than those for water and PF-5060. The local heat transfer coefficients for the paraffin slurry were larger than those for water and the local heat transfer coefficients reached a row-number-independent and thermally-fully-developed value approximately after the third row. The local Nusselt numbers for paraffin slurry with a mass fraction of 7.5% were larger by 20~38% than those for water. The paraffin slurry with a mass fraction of 5% shelved the best thermal and hydrodynamic characteristics when local heat transfer and pressure drop were considered simultaneously.

  • PDF

A Experimental Study on the Ultrasonic Influence for Melting the Paraffin the Ice (초음파가 얼음과 파라핀 용해에 미치는 영향에 관한 실험적 연구)

  • 이재효;김태훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1106-1113
    • /
    • 2001
  • This paper presents experimental works on the ultrasonic influence during melting of ice and paraffin and compared the paraffin's result with ice's results. The experiments was carried out under two setting conditions.: 1) Heater without ultrasonic vibration, 2) heater with ultrasonic vibration. Experimental observations show that the ultrasonic vibration enhances significantly the phase-change process (melting) so that the melting time is reduced about 16∼25% compared to those of molting process without ultrasonics in the melting of both ice and paraffin. But the influence of ultrasonics was not significant to affect the reduction of the power consumption. In the case of paraffin, the reduction rate of power consumption was about 20%, but the reduction of the power consumption was increased about 0∼12%.

  • PDF

The Effect of Paraffin Therapy on Release of pain and Range of motion with Joint Disease Patients (관절 질환의 통증과 가동력에 파라핀 치료가 미치는 효과)

  • Lee, Suk-Min;Kwon, Ki-Ja
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.130-139
    • /
    • 2003
  • This study was conducted in order to determine the effect of Paraffin Therapy on release of pain, skin temperature and range of motion with joint diseases. This study was performed on 42 patients with general joint diseases and 21 patients with degenerative joint diseases. All the subjects were randomly assigned to three groups with 21 each. The experiment had been done from June, 1. 2002 to September, 30. 2002, in two general hospitals and a social welfare center using Digital Thermometer Kane-May KM330 and VAS(visual analogue scale). Each pint was measured in terms of skin temperature, pain scale and ROM(range of motion). The results of the experiment are as follows : 1. In application of three different heat modalities (Paraffin bath, Infra red, Hydro pack) on the Knee, Ankle, Elbow pints of the subjects for 30 minutes, the elevation of skin temperature and the reduction of pain scale were found to be significantly different. When checked right after the 30 minutes' application, the Infra red resulted in a higher degree elevation of skin temperature than two other modalities, while Paraffin bath resulted in the highest degree of the elevation of skin temperature when it was checked one hour after the application was over. It means that Paraffin bath lasted longer than the other two modalities(F=14.691, p<.000). 2. With Paraffin bath application, pint pain was reduced significantly both in 30 minutes and one hour checks(F=20.675, p<.001). 3. In terms of ROM(range of motion) increase, didn't seem to have any significant differences in 30 minutes and one hour. The results suggest that Paraffin therapy be helpful in maximizing th effects on pint diseases. I strongly suggest that further studies be done on other pints and muscle diseases using Paraffin bath in different methods of applying the therapy.

  • PDF

Thermal Characteristics of Discrete Heat Sources Using Coolants

  • Choi, Min-Goo;Cho, Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2001
  • The present study investigated the effects of experimental parameters on the thermal characteristics of an in-line 6x1 array of discrete heat sources for a test multichip module using water, PF-5060 and paraffin slurry. The parameters were heat flux of 10-40W/$cm^2$. Reynolds number of 3,000~20,000 and mass fraction up to 10% for paraffin slurry The size of paraffin slurry was within 10~40$\mu$m before and after experiments. The local heat transfer coefficients for the paraffin slurry were larger than those for water. Thermally fully developed conditions were observed after the third or fourth row (five or seven times of the chip length) and the paraffin slurry showed effective cooling performance at the high heat flux The paraffin slurry with the mass fraction of 5% showed the most efficient cooling performance when the heat transfer and the pressure drop in the test section are considered simultaneously. The experimental data at the fourth and sixth rows are best agreed with the values predicted by the Malina and Sparrow`s correlation among other correlations, and the empirical correlations for water and 5% paraffin slurry were obtained at the first and sixth rows when the channel Reynolds number is over 3,000.

  • PDF

Removal of Paraffin Wax from Ceramic Injection Mold Using Supercritical Carbon Dioxide (세라믹 사출성형체로부터 초임계이산화탄소를 이용한 파라핀왁스의 제거)

  • Kim, Dong-Hyun;Hong, Seung-Tae;Yoo, Ki-Pung;Lim, Jong-Sung
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Removal of paraffin wax from a ceramic injection mold using supercritical $CO_2$ has been studied. The paraffin wax is used as a binder in the ceramic injection molding process. The effects of pressure, temperature and flow rate of supercritical $CO_2$ on the removal of the paraffin wax were investigated. The removal rates were measured with various flow rates of $CO_2$ in the range of 328.15 - 348.15 K and 15 - 30 MPa. The removal rate of paraffin wax increased as the pressure increased. In the effect of temperature, the paraffin wax was effectively removed over 329.15K (melting point of paraffin wax), however, the efffct of temperature was not significant when the temperature was further increased. The increase of $CO_2$ flow rate also affected the removal of paraffin wax. However, the effect of flow rate was not observed when the flow rate reached a certain value. Propane was used as a co solvent in order to remove the paraffin wax effectively. When the propane was added to the $CO_2$, the removal efficiency was improved. The paraffin wax was completely removed from the ceramic injection mold without any change in their shape and the structure.