• Title/Summary/Keyword: Paper deterioration

Search Result 1,284, Processing Time 0.027 seconds

Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계)

  • Kim, Sung-Duck;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

Measurement and Analysis of Deterioration in the Automobile Engine Oil (자동차용 엔진오일의 열화도 측정 및 분석)

  • 김원태;최만용;박해원;박정학
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.521-524
    • /
    • 2003
  • This paper is aimed to develop the circuit of a coil-type oil sensor packaged to the automotive engine oil monitoring the deterioration in the driving condition and let a driver notify the optimized time for the exchange of engine oil. By applying the principle which the deterioration of automotive engine oil can be expressed to the dielectric constant, the capacitance bridge circuit and the integrator circuit are designed and packaged to a coil-typed engine oil. In this study. the range of operating temperature of engine oil is experimentally recommended within 55$^{\circ}C$ for the stability of a sensor designed. It is concluded that the characteristics of output voltage converted from the dielectric constant are linearly distributed.

  • PDF

The Prototype Development of an Engine Oil Deterioration Sensor Installed Inside an Oil Filter (오일필터 일체형 엔진오일퇴화감지센서 시작품 개발 I)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.24 no.2
    • /
    • pp.82-89
    • /
    • 2008
  • The purpose of this study is to develop the proto type sensor installed inside an oil filter in order to detect oil deterioration level. The sensor is made up with two concentric cylinders with constant gap in between and a filter element inside the central area. The size will be designed as similar as real oil filters. The sensor will be tested on a test rig, which is circulating engine oil, with the same size of an oil filter adapting housing as real engines'. It will be measured the capacitance of a sample engine oil, then be able to be gotten the dielectric constant. The changes in the dielectric constant could be correlated with the engine oil deterioration level if the sensor development would be completed. In this paper, it will be shown the test results carrying out under variable temperature conditions at atmosphere pressure.

Deterioration Analysis of the Shunting Locomotive Through Precision Diagnosis Assessment : Diesel Engine & Power Transmission Parts (입환기관차의 노후도 정밀진단 : 엔진 및 동력전달장치)

  • Chung Jong-Duk;Kim Jeong-Guk;Hong Yong-Ki;Lee Dong-Hyung;Pyun Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.545-550
    • /
    • 2004
  • The deterioration of a shunting locomotive was characterized for the lifetime assessment. The locomotive has been used for shunting works in steel making processes, and in this investigation, various types of technical evaluation methods for the locomotive parts were employed to assess the current deterioration status and to provide important clue for lifetime prediction. Unlike other rolling stocks in railway applications, the diesel shunting locomotive is composed of major components such as diesel engine, transmission, gear box, brake system, electronic devices, etc. In this paper, the degree of deterioration in a diesel engine and power transmission parts has been presented based on the analysis results.

  • PDF

Deterioration Analysis of a Shunting Locomotive: Carbody and Bogies (입환기관차의 노후도 평가 : 차체 및 대차)

  • Kim Jeongguk;Jong Jong-Duk;Pyun Jang-Sik;Chang Se-Ky;Hong Yong-Ki;Kim Weon-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.269-276
    • /
    • 2004
  • Deterioration analysis was performed on carbody and bogies of a shunting locomotive, which has been used for shunting works in steel making processes. In this investigation, various types of technical evaluation methods for the locomotive were employed to assess the current deterioration status. Corrosion test and nondestructive evaluation (NDE) techniques were employed to demonstrate the wear status of the carbody and bogie parts in the locomotive. Since the locomotive has been working under corrosive environment, the corrosion tests with x-ray analysis for exterior part of the locomotive were conducted to examine the evolution of corrosion reaction, and NDE techniques such as ultrasonic testing, magnetic particle testing, and x-ray radiography, were conducted on the carbody and bogies to inspect any possible inherent and/or in-service flaws. In this paper, the degree of deterioration in a shunting locomotive has been presented based on the analysis results.

  • PDF

Insulation Deterioration of AC/DC Section Insulators for Electric Railroad Catenary. (전기철도 교/직 절연구분장치의 절연열화 현상)

  • 최규형
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.16-22
    • /
    • 2003
  • While passing through the AC/DC section insulators installed at electric railroad catenary, some electric trains undergo mis-operation of main circuit breaker after AC/DC change-over operation. This paper provides insulation resistance measurements of AC/DC section insulators, which confirm the insulation levels of section insulators are below the standard of insulators. The insulation deterioration and pantograph arrangement on the electric train can produce voltage impression on section insulator which induces mis-operation of main circuit breaker To mitigate the insulation deterioration of the section insulator installed at underground railroads, the section insulators have been cleaned periodically, but section insulator structure should be modified to make the section insulator performance perfect. Based on the above analysis, effective modification method of AC/DC section insulator is provided.

Numerical modeling of coupled structural and hydraulic interactions in tunnel linings

  • Shin, J.H.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.1
    • /
    • pp.1-16
    • /
    • 2008
  • Tunnels are generally constructed below the ground water table, which produces a long-term interaction between the tunnel lining and the surrounding geo-materials. Thus, in conjunction with tunnel design, the presence of water may require a number of considerations such as: leakage and water load. It has been reported that deterioration of a drainage system of tunnels is one of the main factors governing the long-term hydraulic and structural lining-ground interaction. Therefore, the design procedure of an underwater tunnel should address any detrimental effects associated with this interaction. In this paper an attempt to identify the coupled structural and hydraulic interaction between the lining and the ground was made using a numerical method. A main concern was given to local hindrance of flow into tunnels. Six cases of local deterioration of a drainage system were considered to investigate the effects of deterioration on tunnels. It is revealed that hindrance of flow increased pore-water pressure on the deteriorated areas, and caused detrimental effects on the lining structures. The analysis results were compared with those from fully permeable and impermeable linings.

An on-line Deterioration Analysis Method of Inverters using Averaged Switch Modeling (평균 스위치 모델링에 의한 인버터의 온라인 열화진단기법)

  • Park, Chan-Guk;Choi, Young-Gil;Koo, Tae-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1199-1201
    • /
    • 2003
  • This paper presents an averaged switch model for an on-line deterioration analysis of inverters. The model is based on the operational characteristics of power diodes and IGBTS. Switching loss mechanisms are described and divided into the diode reverse-recovery mechanism, the IGBT current-tailing phenomenon, the IGBT turn-on time, and the output capacitances of the IGBTS and diodes. The deterioration analysis parameters are derived from the averaged switch modeling and the parameters can determinate the deterioration of the inverters.

  • PDF

Deterioration Analysis of Electric Systems in Diesel Electric Locomotives (디젤전기기관차 전기장치 노후도 평가)

  • Kim, Jeong-Guk;Baek, Seung-Koo;Lee, Chang-Young;Kwon, Sung-Tae;Kwon, Seok-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1213-1219
    • /
    • 2008
  • The deterioration analysis of electric systems in diesel electric locomotives, which were used for over 30 years, was performed to understand current wear and safety information. The electric systems include electric generation, traction motors, control units, high-voltage cables, and wires. In this investigation, various types of performance testing, such as insulation resistance measurement and degradation tests, were conducted to assess the degree of current deterioration. Moreover, an infrared camera was employed to verify abnormal heating in cables and wires. In this paper, the new techniques for evaluation of deterioration in electric systems have been introduced.

  • PDF

RELIABILITY-BASED COMPONENT DETERIORATION MODEL FOR BRIDGE LIFE-CYCLE COST ANALYSIS

  • Rong-yau Huang;Wen-zheng Hsu
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.386-397
    • /
    • 2007
  • One major development in bridge life cycle cost analysis (LCCA) in recent years is to develop deterioration model for bridge components so that the times of repair/replacement throughout a component's life span can be properly determined. Taiwan also developed her own bridge LCCA model in 2003, integrating with the bridge inspection database in the local bridge management system (T-BMS). Under the framework of the local LCCA model, this study employs the reliability method in developing a deterioration model of bridge components. A component deteriorates through time in its reliability, which represents the probability of a component's condition index exceeds a user specified threshold. Model assumptions and rationale are described in the paper. The steps for applying the developed model are explained in detail. Results and findings are reported.

  • PDF