• Title/Summary/Keyword: Panel Type

Search Result 1,205, Processing Time 0.035 seconds

Comparison of vibration and noise of higher utility factor Insulation Panel for Transformer (변압기용 고효율 차음판의 진동 및 소음 비교)

  • Jeong, J.H.;Lee, J.H.;Jeong, H.E.;Lim, D.S.;Kim, J.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.112-116
    • /
    • 2007
  • Highly damped insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in inner city is appeared a lost of problem by increasing to conserve living environment. Therefor in this paper, the vibration and noise characteristic effect of cork-type and sponge-type that is attached between insulation panel and enforce beam in transformer is analized using real size transformer experimentally.

  • PDF

Minimum Weight Design of Stiffened Laminated Composite Cylindrical Panel with R Type Stiffener (R형 보강재로 보강된 복합적층 원통형패널의 최소중량화설계)

  • 원종진;이종선;홍석주
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.103-107
    • /
    • 2001
  • This study is simulation about buckling behavior under axial compression which is cylindrical panel laminated USN125 and USN150 made by various winding angle. And also this study compare with linear and nonlinear FDEM theory, and FEM theory. To solve the objective function and the design variables, this study use the linear and nonlinear buckling theories or FDEM and nonlinear search optimum design method of ADS for minimum weight design on which stiffened laminated composite cylindrical panel with stiffener that R-type section.

Noise Reduction Design of Plasma Display Panel (플라즈마 디스플레이의 저소음 설계)

  • Park, Dae-Kyong;Kweon, Hae-Sub;Jang, Dong-Seob
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.369.2-369
    • /
    • 2002
  • For the evaluation of the plasma display panel (PDP)'s noise, vibration and sound characteristics of fanless PDP are measured and investigated. PDP is a type of two-electrode vacuum tube which operatres on the same principle as a household fluorescent light. An inert gas such as argon or neon is injected between two glass plates on which transparent electrodes have been formed, and the glass is illuminated by generating discharge. (omitted)

  • PDF

Micro Scale Mechanical property of Polymeric materials for FPD(Flat Panel display) (FPD에 사용되는 고분자 재료의 기계적 물성특성 연구)

  • Lee N.K.;Lee H.J.;Lee H.W.;Chong E.G.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.220-224
    • /
    • 2005
  • The technology trend of Flat Panel Display (FPD) equipments have been demanded that there are compact and multi-function. Therefore, nano/micro scale patterned on polymeric materials of Back Light Unit (BLU) in Liquid Crystal Display (LCD) that has been investigated. This paper describes a series of Horizontal Type Micro Tensile Tester that were carried out to investigate the load strain distance performance of typical polymeric material sheets. The polymeric materials film that micro size shaped specimens for tensile test are used by Cold-Isostatic-Press (CIP). Test equipment is Horizontal type Micro Tensile Tester that is presented to measure the micro scale mechanical property of thin film for FPD. This paper presents which easy testing tools measure for micro patterned on polyethylene (PET) specimens.

  • PDF

Transmission Loss Characteristics of the Panel Type Silencer (패널형 소음기의 투과손실 특성 연구)

  • 서상현;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.178-183
    • /
    • 2003
  • This paper deals with transmission loss characteristics of the panel type silencer to control low frequency noise. The panel type silencer is composed of many Helmholtz resonators by side branch. Each resonator has high transmission loss on the narrow band of its resonance frequency. Direct arrangement of the resonators increases mainly the magnitude of transmission loss. If we arrange the resonators in a row, the peak and band of transmission loss are increased. This makes the resonator array to have high transmission loss in the broader band. Using this idea, we design a silencer that has broader band characteristics and smaller volume.

  • PDF

Levy-type solution for analysis of a magneto-electro-elastic panel

  • Jia He;Xuejiao Zhang;Hong Gong;H. Elhosiny Ali;Elimam Ali
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.719-729
    • /
    • 2023
  • This paper studies electro-magneto-mechanical bending studying of the cylindrical panels based on shear deformation theory. The cylindrical panel is constrained with two simply-supported edges at longitudinal direction and two clamped boundary conditions at circumferential direction. The governing equations are derived based on the principle of virtual work in cylindrical coordinate system. Levy-type solution of the governing equations is derived to reduce two dimensional PDEs to a 2D ODEs. The reduced ordinary differential equation is solved using the Eigen-value Eigen-vector method for the clamped-clamped boundary condition. The electro-magneto-mechanical bending results are obtained to show that every displacement, rotation and electromagnetic potentials how change with changes of initial electromagnetic potentials and mechanical loads along longitudinal and circumferential directions.

Analysis of Optical Characteristics According to Electronic Ink Loading Method of Three-Electrode Type E-Paper Display (3전극형 전자종이 디스플레이의 전자잉크 주입 방법에 따른 광학 특성 분석)

  • Lee, Sang-Il;Hong, Youn-Chan;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.3
    • /
    • pp.171-176
    • /
    • 2018
  • An electronic paper display was fabricated by injecting electronic ink, including white and black particles coated by positive and negative charge control agents (CCA), respectively, into closed cells surrounded by micro-barriers. These two types of charged, colored particles are easily damaged or their charging value can be changed by the injection process; therefore, the electrical and optical properties of the image panel fabricated by the injection method were estimated in this study. The active particle-loading method, proposed as a new electronic ink injection process, was applied, and the electro-optical properties of the resulting three-electrode-type e-paper image panel were analyzed. The reflection rate of the white image-panel fabricated with our new injection method was 24.7%, while that of the same panel fabricated with a previously reported injection method was 19.8%. In addition, the response time was improved by about five times compared to those reported in other publications.

Field Emission Characteristics of a CNT-FEA fabricated by Screen-printing of a Photo-sensitive CNT Paste (감광성 CNT 페이스트의 스크린 프린팅법을 이용한 CNT-FEA의 전계 방출 특성)

  • Kwon Sang-Jik;Lee Sang-Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.75-80
    • /
    • 2006
  • We have fabricated a carbon nanotube field emission display(CNT-FED) panel with a 2 inch diagonal size using a screen printing method and in-situ vacuum sealing technology. The field emission properties of CNT FED panel with square-type CNT emitters. As results, the square-characterized and compared with those of the line-type CNT emitters. As results, the square-type CNT emitters showed much larger emission current and more stable I-V characteristics. Light emission started to be occurred at an electric field of 3.5 V/${\mu}m$ corresponding to the anode-cathode voltage of 700 V. The vacuum level inside of the in-situ vacuum sealed panel was obtained with $1.4 {\times} 10^{-5}$ torr. The sealed panel showed the similar I-V characteristics with the unsealed one and the uniform light emission with very high brightness at a current density of $243 {\mu}A/ cm^2$ obtained by the electric field of 10 V/${\mu}m$.

Comparison of vibration and noise characteristic of high efficiency Insulation Panel for Transformer (변압기용 고효율 차음판의 진동 및 소음 비교)

  • Jeong, J.H.;Jang, Y.S.;Lim, D.S.;Kim, J.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1005-1009
    • /
    • 2008
  • The high efficiency insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in side of city is appeared a lost of problem by increasing to conserve the living environment. Therefor in this paper, first the vibration and noise characteristic of existing insulation panel is analyzed according to attached material, cork and sponge-type. Second the insulation of sound performance is compared between the existing insulation panel. And high efficiency insulation panel that is proposal in this paper.

  • PDF

Effect of Panel Density and Resin Content on Properties of Medium Density Fiberboard

  • Hong, Min-Kug;Lubis, Muhammad Adly Rahandi;Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.444-455
    • /
    • 2017
  • This study was conducted to evaluate the effect of panel density and resin content on properties of medium density fiberboard (MDF) to obtain some insights on MDF properties as a function of panel density and resin content. MDF panels with different panel densities such as 650, 700, 750 and $800kg/m^3$ were manufactured by adjusting the amount of wood fibers in the mat forming. MDF panels were also fabricated by spraying 8, 10, 12, and 14% of urea-formaldehyde (UF) resins onto wood fibers in a drum-type mechanical blender to fabricate MDF panels with a target density of $650kg/m^3$. As the panel density and resin content increased, the internal bonding (IB) strength of MDF panel consistently increased. Modulus of rupture (MOR), modulus of elasticity (MOE) and screw withdrawal resistance (SWR) had a similar trend to the IB strength. In physical properties, thickness swelling (TS) and water absorption (WA) decreased with an increase in both panel density and resin content. In addition, the formaldehyde emission (FE) which increased as the panel density and resin content became greater. In overall, the panel density of MDF had more significant effect than the resin content in all properties of MDF panels, indicating that it was better to adjust the panel density rather than the resin content for MDF manufacture.