• Title/Summary/Keyword: Panel Board

Search Result 230, Processing Time 0.025 seconds

Ownership Concentration, Board Education Diversity, and Environmental Accounting Disclosure in Kenyan Listed Firms. Moderation Approach

  • TARUS, John Kipngetich
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • The purpose of this study was to examine the moderating effect of board education diversity on the relationship between ownership concentration and environmental accounting disclosure. The study was driven by stakeholder's theory. The longitudinal research design was adopted in the study. The study targeted 27 listed firms from 2008 to 2017. Panel regression analysis results indicated ownership concentration (β = -.131, ρ<.05) had a negative and significant effect on environmental disclosure in Kenyan firms. However, Board education diversity positively moderated the relationship between ownership concentration (β=.138, ρ<.05) and environmental accounting disclosure. Thus, board education diversity is an enhancing moderator in the relationship between ownership concentration and environmental accounting disclosure. The findings validate stakeholder theory's proposition. The study recommends that firms listed in the NSE ought to diffuse ownership concentration, and their boards should be well educated and experienced to enhance environmental accounting disclosure.

TRIO-CINEMA의 시스템 harness

  • Jeon, Je-Heon;Lee, Hyo-Jeong;Chae, Gyu-Seong;Seon, Jong-Ho;Jin, Ho;Lee, Dong-Hun;Lin, Robert P.;Immel, Thomas
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.199.1-199.1
    • /
    • 2012
  • TRIO-CINEMA(TRiplet Ionospheric Observatory-Cubesat for Ion, Neutron, Electron & MAgnetic field)는 지구근접공간에서의 미세 자기장 변화 및 중성입자의 검출을 목적으로 경희대학교와 UC Berkeley가 공동 개발하는 초소형위성이다. 초소형위성은 내부 공간이 협소하여 효율적인 공간배치 및 위성체발사 시 진동에도 견딜 수 있도록 harness가 제작되어야 한다. CINEMA는 OBC, EPS, 배터리, 수신기, IIB(Instrument Interface Board), MAGIC(MAGnetometer Imperial College) board, HVPS(High Voltage Power Supply)로 구성된 avionics bus와 MAGIC, STEIN(Supra Thermal Electron, Ion, Neutral)의 payload, Solar panel, UHF와 S-band 안테나로 구성되어 있다. Solar panel에서 생산된 전력은 EPS를 통해 배터리에 저장되고 PC104를 통해 avionics stack의 각 board로 전력이 분배된다. IIB는 탑재체 파트와 연결되어 이를 제어하고 HVPS에서 STEIN에 공급되는 고전압은 특수 와이어를 통해 연결되며 UHF 안테나와 S-band 안테나는 RF 케이블로 수신기와 송신기가 연결되어 있다. 각각의 harness는 케이블타이와 lacing tape로 위성체와 고정되며 커넥터는 고정 지지대를 제작하여 나사로 체결하였다. CINEMA에 적용된 harness는 진동시험과 열진공시험을 통해 harness와 시스템의 안정성이 검증 되었다.

  • PDF

Evaluation of the Performance of the PVA Fiber Reinforced Inorganic Binder and Industrial By-products Building Board

  • Park, Jong-Pil;Lee, Sang-Soo;Song, Ha-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • The test on the mix of PVA fiber of low carbon inorganic composite as a cement substitute found it to be satisfactory in terms of flexibility and stiffness. The result of the evaluation of the properties of low carbon inorganic panel revealed that the absorptivity was low at 8 to 9%, which is lower than the KS value of 25%. Also, the test on non-combustibility and gas toxicity found that these factors satisfied the decision criteria. In the test on heavy metals discharges, Pb, Cd, Cr6+, Hg, and As were not detected. Regarding far-Infrared emissivity and formaldehyde emission, the substitute was found to be harmless to the human body. Therefore, if the issue of shrinkage, which is a disadvantage of inorganic composites, is addressed, it is judged that it is possible to develop a low carbon inorganic composite panel with better performance.

Development of the Anti-vibration Base for the Onboard Equipment of the Naval Vessel Using Sandwitch Panel (샌드위치 패널을 이용한 함정탑재장비용 방진 베이스 개발)

  • Han, HyungSuk;Lee, KyoungHyun;Park, SungHo;Wi, YangHyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.365-374
    • /
    • 2016
  • The underwater radiated noise can be reduced by decreasing the structure borne noise of the on-board equipment. Therefore, the structure borne noise of the onborad installed equipment is strongly restricted by ROK navy with MIL-Std 740-2. Usually, the vibration transmissibility from the equipment to the hull of the ship is dependent on its mount characteristics. Even though the double mount structure is proper to apply for ship board application rather than single mount, it is not widely applied due to the weight and volume resriction of the ship. Therefore, in this research, the base using sandwitch panel which can act as double mount structure is suggested and its noise reduction capacity is verified with analytic calculation as well as experiment.

A Development of Energency Power Automatic Transfer Module in home (가정용 비상 전원 절체 모듈 개발)

  • Joo, Nam-Kyu;Kim, Kwan-Yuong;Kim, Nam-Ho;Lee, Jong-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

Development of n Remote Monitoring System for TFT-LCD Panel Test Automation (TFT-LCD 채널검사 자동화를 위한 원격 모니터링 시스템 개발)

  • Park, Hyoung-Keun;Lee, Seung-Dae;Kim, Sun-Youb
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.483-487
    • /
    • 2007
  • In this study, we develop a new remote monitoring system for TFT-LCD panel test automation. Having to realtime monitor of Ti-Con board, this system needs to discrimination whether breakdown or not that is able to transmit processing data for engineer at long distance place using TCP/IP. The result of the development, that can be fast opposition to the breakdown and the multiple processing

  • PDF

Predicting electrodeposition thickness distribution by placing panel on PCB panel (PCB panel 도금에서 panel 위치에 따른 도금 두께 분포 예측)

  • Hwang, Yang-Jin;Park, Yong-Ho;Lee, Gyu-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.54-54
    • /
    • 2011
  • 금속의 원자재 가격 상승으로 인하여 도금산업에서는 도금두께 균일도에 대한 정밀도를 더욱 요구하게 되었다. 특히, PCB(Printed Circuit Board) 산업에서는 초소형, 고밀집 제품이 주를 이루고 있기 때문에 도금두께를 정밀하게 제어하기에는 어려움이 따른다. 이에 PCB panel 제품에 대한 도금두께를 정밀하게 제어하기 위해 시뮬레이션을 이용하여 차폐판을 최적 설계하였다. 시뮬레이션의 정확도를 향상시키기 위하여 RDE(Rotaing Disk Electrode) 시스템을 사용하여 도금용액에 대한 전기화학 분석을 진행하였다. 27인치 PCB 제품에 대하여 차폐판을 적용한 결과, 기존에 비해 전류밀도분포 균일도가 약 20% 정도 향상되었다.

  • PDF

The Development of Portable Rotor Bar Fault Diagnosis System for Three Phase Small Induction Motors Using LabVIEW (LaVIEW를 이용한 휴대용 3상 소형유도전동기 회전자 바 고장 진단 시스템 개발)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Lee, Tae-Hun;Woo, Hyeok-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper, a portable rotor bar fault diagnosis system for small 3 phase induction motors is suggested. For portable real-tine diagnosis system, an USB-DAQ board for collecting the 3 phase current data, three current probes, and a notebook computer are used. The LabVIEW graphical language is used for filtering, analysis, storing, and monitoring the current data. The three phase stator current are filtered and transformed to frequency level by FIT. An analysis window programed by LabVIEW is located in front panel to show the FIT results and this suggested window has a zooming function to detect the fault feature more easily near the feature frequency range which is varying by the slip frequency. To show the possibility of portable rotor bar diagnosis system, three types(healthy, one rotor bar fault, two rotor bar fault) of rotor bar are intentionally prepared and compared by the suggested window of front panel. Experimental results are shown that a suggested diagnosis system is applicable to portable diagnosis system and the rotor bar fault is detected by the frequency window in front panel programed in LabVIEW graphical language.

Study on the Conduction Heat Transfer Characteristics According to the Heating Temperature of Lightweight Panel Wall material (경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성 연구)

  • Park, Sang-Min;Lee, Ho-Sung;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.46-56
    • /
    • 2018
  • The paper relates to a study on the conduction heat transfer characteristics according to the heating temperature of lightweight panel wall material. Plywoods, marbles, heat resistant glasses, as well as general gypsum board and fire-proof gypsum board, which have been widely used for lightweight panel wall material, were selected as experiment samples, and heating temperatures were set as $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$ and $600^{\circ}C$. Next, each of the heating temperatures were introduced on the bottom part of the wall material for 30 minutes, and analyses were made on the heat transfer characteristics to the backside part on the top part through conduction. As results of the experiment, the maximum backside temperatures were measured up to $190^{\circ}C$ for a general gypsum board, $198^{\circ}C$ for a fire-proof gypsum board, $189^{\circ}C$ for a plywood, $321^{\circ}C$ for a marble, and $418^{\circ}C$ for a heat resistant glass as heating temperatures were introduced maximum of $600^{\circ}C$. In addition, the maximum change rate of conduction heat transfer were measured up to 85 W for a general gypsum board, 95 W for a fire-proof gypsum board, 67 W for a plywood, 1686 W for a marble, and 3196 W for a heat resistant glass as the maximum heating temperatures were introduced up to $600^{\circ}C$. Also, carbonization characteristics of the wallpapers were measured to visually check the danger of conduction heat transfer, and the results showed that smokes were first generated on the attached wallpapers for the heating temperature $600^{\circ}C$, which were 1021 s for a general gypsum board, 978 s for a fire-proof gypsum board, 1395 s for a plywood, 167 s for a marble, and 20 s for a heat resistant glass, and that the first generation of carbonization were 1115 s for a general gypsum board, 1089 s for a fire-proof gypsum board, 1489 s for a plywood, 192 s for a marble, and 36 s for a heat resistant glass.

Distributing Board Monitoring System based on Internet of Things (사물인터넷 기반 수배전반 상태 모니터링 시스템)

  • Lee, Young-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.200-206
    • /
    • 2016
  • It is necessary to develop a real-time monitoring system for electric facilities, operating and managing system for the accident prevention of electrical demand facilities anytime, anywhere. In this paper, we propose the implementation of distributing board monitoring system based on Internet of Things(IoT). The proposed system is installed in existing distributing board that it can transmit status information of distributing board and control information through the cloud server and the wireless local area network. The distributing board monitoring system can monitor and control the condition of distributing board by system administrator. The results show that the margin of error was ${\pm}5%$ in performance evaluation.