AC Losses of the HTS Pancake Coil by Using Electric Method (전기적 측정법을 사용한 팬케이크 코일에서의 교류손실 측정)

  • 이승욱;임형우;최명섭;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.37-40
    • /
    • 2003
  • This paper presents calculated and measured AC losses of the HTS pancake coil. Magnetic field in the HTS coil under operating conditions was calculated by FEM. Results of measured ac loss in 4-stacked short sample were used in the AC loss calculation. Various methods, such as, electric method, calorimetric method, wattmeter method, were used to measure the AC loss.

  • PDF

Embedding between Macro-star and Pancake Graphs Using the Graph edge (그래프 에지를 이용한 매크로-스타(Macro-star)와 팬케익(Pancake) 그래프간의 임베딩)

  • Min, Jun-Sik;Choe, Eun-Bok;Lee, Hyeong-Ok
    • Annual Conference of KIPS
    • /
    • 2003.05a
    • /
    • pp.161-164
    • /
    • 2003
  • n-차원 스타 그래프와 펜케익 그래프의 노드 개수는 n!개로서, 하이퍼큐브가 갖는 좋은 성질을 가지면서 하이퍼큐브 보다 망 비용이 적은 값을 갖는 상호연결망이다. 본 논문에서는 스타 그래프와 팬케익 그래프가 동일한 노드 개수를 가질 때, 두 그래프의 에지 정의를 이용하여 스타 그래프 $S_n$을 팬케익 그래프 $P_n$에 연장율 4, 확장율 1에 임베딩 가능함을 보이고. 펜케익을 매크로-스타에 임베딩 하는 비용이 O(n)임을 보인다.

  • PDF

A Joining Method between HTS Double Pancake Coils (고온초전도 더블 팬케이크 코일들 사이의 접합 방법)

  • Sohn, Myung-Hwan;Sim, Ki-Deok;Kim, Seok-Ho;Kim, Hae-Jong;Bae, Joon-Han;Lee, Eon-Young;Min, Chi-Hyun;Seong, Ki-Chul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.633-639
    • /
    • 2006
  • High temperature superconductor (HTS) winding coil is one of the key component in superconducting device fabrication. Double-pancake style coils are widely used for such application. High resistance between pancake coils greatly affects the machine design, operating condition and thus the stability. In order to reduce such resistance, experimentalists are looking for efficient and damage free coil connecting methods. In this respect, here we proposed parallel joining method to connect the coils. This is to do crossly joining with HTS tapes on two parallel HTS tapes. Joint samples between two parallel HTS tapes were prepared by using HTS tapes and current-voltage (I-V) characteristic curves were investigated at liquid nitrogen temperature i.e., 77.3 K. A 20 cm length joint connected between two parallel HTS tapes shows $32.5n{\Omega}$, for currents up to 250 A. A small HTS magnet, having two double pancake sub-coils connected together through new parallel joint method was fabricated and their current-voltage (I-V) characteristic curve was investigated. At 77.3K, critical current(Ic) of 97 A and resistance of $55n{\Omega}$ for currents upto 130 A were measured. At operating current 86 A lower than Ic, Joule heats generated in whole magnet and at joint region between sub-coils were 226 mW and 0.4 mW, respectively. Low Joule heat generation suggests that this joining method may be used to fabricate HTS magnet or windings.

Fault Current Limiting Characteristic of Non-inductively Wound HTS Magnets in Sub-cooled $LN_2$ Cooling System

  • Park Dong-Keun;Ahn Min-Cheol;Yang Seong-Eun;Lee Chan-Joo;Seok Bok-Yeol;Yoon Yong-Soo;Ko Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.29-32
    • /
    • 2006
  • An advanced superconducting fault current limiter (SFCL) using $high-T_c$ superconducting (HTS) wire has been developed. The SFCL has a non-inductively wound magnet for reducing loss in normal state. Two types of non-inductively wound magnets, the solenoid type and the pancake type, were designed and manufactured by using Bi-2223 wire in this research. Short-circuit tests of the magnets were performed in sub-cooled $LN_2$ cooling system of 65 K. The magnets are thermally more stable and have a higher critical current in 65 K sub-cooled $LN_2$ cooling system than in 77 K saturated one. Because the resistivity of matrix at 65 K is lower than the resistivity at 77 K, the magnets generate a small resistance to reduce the fault current when the quench occurs. The magnets could limit the fault current to low current level with such a small resistance. The current limiting characteristic of the magnets was analyzed from the test result. The solenoid type was wound in parallel to make it non-inductive. The pancake type was also connected in parallel to be compared with the solenoid type in the same condition. The solenoid type was found to have a good thermal stability compared with the pancake type. It also had as large resistance as the pancake type to limit the fault current in sub-cooled $LN_2$ cooling system.

Magnetic Field Analysis of 1 MVA HTS Transformer Windings

  • Park, Chan-Bae;Kim, Woo-Seok;Lee, Sang-Jin;Han, Jin-Ho;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Hahn, Song-Yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.66-70
    • /
    • 2003
  • In a HTS transformer, the perpendicular component of magnetic flux density ($B_r$) applied to HTS tapes of pancake windings becomes larger than that of solenoid winding, thereby decreasing the critical current in the HTS tapes. This paper introduces several methods to reduce $B_r$ applied to the HTS tapes in the transformer with double pancake windings by changing winding arrangements and the relative permeability of flux diverters. We have conducted a winding design for a single-phase 1MVA 22.9kV/6.6kV HTS transformer. We observed a change of $B_r$ due to a variation of gap-length between the high voltage windings and the low voltage windings, reciprocal arrangement and an increase of the number of the high voltage pancake. We also observed a change of Br on the HTS tapes due to variation of the relative permeability of flux diverters placed between the high voltage winding and the low voltage winding. Finally, we have designed a 1MVA 22.9kV/6.6kV HTS transformer winding using suggested methods and calculated transformer parameters by the 3D finite element method.

Design of a 1 MVA HTS Transformer with Double Pancake Windings

  • Kim, Woo-Seok;Park, Kyeong-Dal;Joo, Hyeong-Gil;Han, Jin-Ho;Hong, Gye-Won;Park, Jungho;Heesuck Song;Kim, Sung-Hoon;Hahn, Song-yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.48-51
    • /
    • 2003
  • A 1 MVA transformer with BSCCO-2223 high Tc superconducting (HTS) tapes was designed. The rated voltages of each sides of the transformer are 22.0 kV and 6.6 kV respectively. Double pancake HTS windings, which have advantages of insulations and distribution of high voltage, were adopted. Four HTS tapes were wound in parallel fer the windings of low voltage side. Each winding was composed of several double pancake windings made of four parallel conductors were transposed in order to distribute the currents equally in each conductor. A core of the transformer was designed as a shell type core made of laminated silicon steel plate and the core is separated with the windings by a cryostat with a room temperature bore. The operating temperature of HTS windings will be 65K with liquid nitrogen, and a cooling system using a cryocooler was proposed and designed conceptually. This HTS transformer is going to be manufactured in near future based on the design parameters presented in this paper.

A Study on AC loss Characteristics of Asymmetric non-inductive coils with Combination of Superconducting wires (초전도 선재 조합에 따른 비대칭 무유도성 코일의 교류 손실 특성 연구)

  • Kim, J.S.;Hwang, Y.J.;Na, J.B.;Choi, S.J.;Kim, Y.J.;Lee, J.H.;Lee, W.S.;Chang, K.S.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.17-21
    • /
    • 2011
  • A hybrid superconducting fault current limiter (SFCL) with fast switch had been previously suggested by our research group. To make a hybrid SFCL, different superconducting wires were wound two pancake coils so that two pancake coils had asymmetric configuration. The impedance of the asymmetric non-inductive coils are zero with applied normal current. However during the fault. currents were distributed unequally into the two pancake coils because each superconducting wires have different electrical characteristics. This unequal distribution of current causes effective magnetic flux which generate repulsive force. Fast switch was thus opened by the force applied to the aluminum plate which consists of SFCL. In this paper, the AC loss characteristics of the asymmetric non-inductive coils with combinations of superconducting wires were studied and calculated by related experiments and finite element method (FEM) simulation. From these results, we suggested the appropriate combination of two superconducting wires to be used for the asymmetric non-inductive coils.

Energy and Inductance of a HTS Magnet with Various Aspect Ratios (마그넷 형상에 따른 고온초전도 마그넷의 에너지와 인덕턴스)

  • Kang, Myung-Hun;Kim, Young-Min;Ku, Dae-Kwan;Paik, Kyoung-Ho;Cha, Guee-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1134-1139
    • /
    • 2011
  • When the aspect ratio of a magnet varies, the magnetic field in the magnet also varies. The critical current of a tape-shaped HTS wire varies with the direction and magnitude of applied magnetic field. Consequently when the aspect ration of a HTS magnet varies, the critical current of a HTS magnet varies. This paper shows the relation between the aspect ratio of a magnet and the energy and inductance of a HTS magnet. The critical current is also shown at various aspect ratio of the magnet. The length of the HTS wire, inner diameter of the magnet, and number of pancake are chosen to be variables which varies the shape of the magnet. For a HTS magnet consisting of pancake windings, calculation results show the number of pancake windings are the prime factor which varied the energy and inductance of the magnet. The inner diameter of the magnet varies the energy and inductance of the magnet a little.

Short-circuit Analysis of Solenoid and Pancake Type Bifilar Winding Magnets using BSCCO tape

  • Park Dong Keun;Ahn Min Cheol;Yang Seong Eun;Yoon Il Gu;Kim Young Jae;Ko Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.28-31
    • /
    • 2005
  • To verify the feasibility of bifilar winding type superconducting fault current limiter (SFCL) using BSCCO tape, two types of magnets were fabricated and tested by short-circuit in this research. Even if the FCL using high Tc superconducting (HTS) tape has zero resistance in normal state, it needs to be wound as a bifilar winding for zero inductance. Solenoid type and pancake type bifilar winding magnets are designed and fabricated with the same length of BSCCO tape. The test system consists of AC power supply, transformer, fault switch, load and bifilar winding magnet. The applied AC voltages during fault duration, 0.1s, were from 0.5V to 20V. The test results without bifilar winding magnet were compared with those with each type magnets. The test results include voltage against magnet, transport current and generated resistance curve. Thermal stability, the recovery time, was studied from the results of two type magnets. The pancake type was the most effective to limit fault current but the solenoid type was thermally the most stable. From this research, short-circuit characteristics of the two types were obtained.

Analysis of the Operational Characteristic of a High-Tc Superconducting Power Supply for Charging of the Superconducting Magnet (초전도자석 충전용 고온초전도전원장치의 특성해석)

  • Yun, Yong-Su;Kim, Ho-Min;An, Min-Cheol;Bae, Deok-Gwon;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.159-164
    • /
    • 2002
  • This paper presents the design and fabrication of a high-Tc superconducting (HTS) power supply for charging of the HTS magnet load, and its characteristics have been analyzed through experiments. HTS power supply consists of two heaters, an electromagnet, a Bi-2223 solenoid and a Bi-2223 pancake magnet load. In this experiment, 331 mH electromagnet and 0.8 A dc heater current were used, and 8.5 sec and 17 sec were used for pumping period. Mechanism of the superconducting switch is used for heater-trigger. In order to measure the pumping-current with respect to the magnet flux changes, hall sensor was installed at the center of the Bi-2223 pancake load. The experimental observations have been compared with the theoretical predictions. In this experiment, the pumping-current has reached about 1.2 A. In computer simulation, the maximum pumping-current of the system has been predicted to be about 2.7 A.