• 제목/요약/키워드: Palladium-silver alloy

검색결과 21건 처리시간 0.024초

팔라디움-은합금의 반복주조시 도재와 금속간의 화학적 결합에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE CHEMICAL BOND STRENGTH AT THE INTERFACE BETWEEN PORCELAIN AND SUCCESSIVELY RECAST PALLADIUM-SILVER CERAMIC ALLOY)

  • 김태균;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제27권1호
    • /
    • pp.31-47
    • /
    • 1989
  • The purpose of this study was to evaluate the chemical bond strength of successively recast Pd-Ag ceramic alloys with porcelain and to investigate changes of quantity of trace elements at the metal-porcelain interface. Porcelain was fired as usual manner on the each successively recast specimen. Rectangular planar shear test was performed and bond strength was measured by Instron universal testing machine. Diffusion of trace elements at the each interface was observed by ESCA (Electron Spectroscopy for Chemical Analysis). The obtained results were as follows : 1. Chemical bond strength was significantly decreased after second recasting. But in case of first recasting, there was no significant decrease of bond strength statistically (p<0.05). 2. Bond strength was not significantly decreased in each generation, when fifty percents new alloy was added (p<0.05). 3. Ag, Sn and In were observed at the porcelain interface. But Pd was not observed. 4. The quantity of Ag, In ions were progressively increased at the metal-porcelain interface as the casting was repeated. Silver ion was most significantly increased.

  • PDF

도재소부용 고금함유금합금의 연구 - 도재 결합층을 중심으로 - (A Study on Metal-Porcelain Fusing Layer in Porcelain Fused to High Gold Alloy)

  • 이기대;곽동주
    • 대한치과기공학회지
    • /
    • 제31권3호
    • /
    • pp.15-20
    • /
    • 2009
  • The success of the porcelain fused to gold alloy restoration depends not only on the choice of materials but to a larger degree on the technical skills. The porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory. The gold-colored alloys contain primarily gold, platinum, palladium, and silver, with minimum amounts of such metals as tin, iridium, or titanium. The purpose of this study is on the metal-porcelain fusing layer in porcelain fused to high gold alloy Principal results are as follows. The hardness number(Hv) of PFG is respectively $140.2{\pm}12.6$ in as-casted, $164.3{\pm}14.3$ in heat-treated, $186.6{\pm}20.4$ in fired-treated. The formation of the fusing(intermediate) layer caused by components fusing the interface of porcelain and gold alloy. The main components of the fusing(intermediate) layer are Na, Al, Si, K, Zn, Zr and Ce. The intermediate layer formed by the 2nd firing is more larger than the intermediate layer formed by the 1st firing.

  • PDF

Pd-In-Ag 합금의 변색거동에 관한 연구 (Tarnish Behavior of Palladium-Indium-Silver alloy)

  • 김화수;김성윤;이규환;신명철;조만형
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.125-129
    • /
    • 1998
  • 치과재료로서 금합금을 대체하기 위하여 Pd-In-Ag 합금을 설계해서 인공체액과 0.9% Nacl용액 링거용액에서 변색실험을 행하였다. 인공체액과 0.9% Nacl 용액에서는 은의 함량증가에 대하여 높은 변색을 보였으나 링거용액에서는 은의 함량 증가에 따른 변색 영향이 관찰되지 않았다. 합금개발을 위하여 Pd와 In, Ag의 변색 영향을 조사하였고 새로운 합금의 설계가 시도되었다.

  • PDF

치과용(齒科用) 은(銀)-파라디움합금(合金)의 합금원소(合金元素)가 제성질(諸性質)에 미치는 영향(影響)에 관(關)한 연구(硏究) (EFFECTS OF ALLOYING ELEMENTS ON VARIOUS PROPERTIES OF DENTAL SILVER-PALLADIUM ALLOYS)

  • 김춘진;박남수
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.95-108
    • /
    • 1984
  • Even though the tarnishing and corrosion problems characteristic with dental silver-palladium alloy are not yet fully solved, it is recently widely used because of its low cost. However the effects of major alloying elements on the various properties of this system are not fully understood. The object of this research is to clarify the effects of In and Zn additives on the corrosion and tarnishing resistances and precipitation hardening behavior of this sytem, using electrodynamic polarization, immersion, and Vicker's microhardness test and X-ray diffraction and electron probe micro analysis methods. The obtained results were as follows: I. As indium content is increased, both the corrosion resistance in Cl-solution and microhardness are also increased while the tarnishing resistance is decreased. 2. As Zinc content is increased, the corrosion resistance is decreased, but tarnishing resistance is increased 3. At 70Ag-25Pd-2.5Zn-2.5In composition, the precipitation harding behavior was mot significant. The optimum aging temperature was $450^{\circ}C$ and the time was 2 hrs. The resulting specimen of this work carried 180VHN. 4. Under the heat treatment, the changes in the mechanical property are due to the changes in the shape and composition of dendrite matrix, namely, it is because of the precipitation hardening behavior which has been proved by electron probe micro analysis and optical microscopic finding.

  • PDF

카복실레이트계 시멘트의 접착력에 관한 비교 연구 (COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS)

  • 이한무
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

도재소부용 18K 금합금의 미량원소의 첨가에 따른 물리적 성질의 변화에 관한 연구 (A Study on Change of Physical Property in Porcelain Fused to 18K Gold Alloy by Small Additional Elements)

  • 이기대
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.31-37
    • /
    • 2008
  • A variety of the porcelain fused to gold(PFG) have been developed to which porcelain can be fused. PFG alloys developed for this purposed have a high melting point and do not discolor when combined with porcelain. The design of the compositions of PFG is very important to esthetic restorative materials applying to porcelain. The purpose of this study is on the change of physical and mechanical characteristics in PFG 18K alloy by the small additional elements. Principal results are as follows. The high Au alloy containing 18Karat gold contents is respectively Au(75%), Pd(10%), Pt(4%), Ag(4%), In(2%), Sn(2%), Cu(2%), Ti(1%). These alloys are composed mainly of gold, platinum, silver and palladium with a few percent of the additional elements. By the addition of small amounts of elements such as In, Sn, Ti, the fine grain castings are produced in gold alloy and the small addition of platinum is very effective in increasing of hardness and strength. These gold alloys are representative of the changes to be expected as a result of heat treatment. These changes in strength and hardness values are sufficient to demonstrate a significant difference in performance between a as-casted and a heat-treated. These alloys have mechanical properties characteristics of Type and Type gold alloys. These alloys are useful to porcelain-metal restorations and dental laboratory. Also the porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory.

  • PDF

상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례 (Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service)

  • 이준식;한세진;최유성
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.71-80
    • /
    • 2014
  • 골흡수가 심한 환자에서 임플란트를 이용한 전악 수복의 경우 치은과 치아의 외형을 심미적이면서도 기능적으로 회복하기 위해서는 보철물 제작에 있어 신중을 기해야 한다. 이러한 전악 수복 증례에서 CAD/CAM 시스템이 높은 정확성을 가지는 보철물 제작을 가능하게 함으로써 사용이 증가하고 있다. 최근에 임상에서 티타늄이나 지르코니아의 단점을 보완하면서 높은 생체적합성을 가지고 CAD/CAM 시스템으로 제작할 수 있는 팔라듐-은(Pd-Ag) 합금이 개발되어 사용되고 있다. 본 증례에서는 상악 전부 무치악 환자에서 임플란트를 식립하고 도재의 chipping이나 파절의 위험을 감소시키기 위해 Pd-Ag 합금을 이용해 제작된 임플란트 고정성 보철물로 수복한 환자에 대해 보고하고자 한다.

A Study on the Electrical Characteristics of Different Wire Materials

  • Jeong, Chi-Hyeon;Ahn, Billy;Ray, Coronado;Kai, Liu;Hlaing, Ma Phoo Pwint;Park, Susan;Kim, Gwang
    • 마이크로전자및패키징학회지
    • /
    • 제20권4호
    • /
    • pp.47-52
    • /
    • 2013
  • Gold wire has long been used as a proven method of connecting a silicon die to a substrate in wide variety of package types, delivering high yield and productivity. However, with the high price of gold, the semiconductor packaging industry has been implementing an alternate wire material. These materials may include silver (Ag) or copper (Cu) alloys as an alternative to save material cost and maintain electrical performance. This paper will analyze and compare the electrical characteristics of several wire types. For the study, typical 0.6 mil, 0.8 mil and 1.0 mil diameter wires were selected from various alloy types (2N gold, Palladium (Pd) coated/doped copper, 88% and 96% silver) as well as respective pure metallic wires for comparison. Each wire model was validated by comparing it to electromagnetic simulation results and measurement data. Measurements from the implemented test boards were done using a vector network analyzer (VNA) and probe station setup. The test board layout consisted of three parts: 1. Analysis of the diameter, length and material characteristic of each wire; 2. Comparison between a microstrip line and the wire to microstrip line transition; and 3. Analysis of the wire's cross-talk. These areas will be discussed in detail along with all the extracted results from each type the wire.

CAD-CAM Konus type 부착장치를 이용한 하악 임플란트 피개의치 보철수복 증례 (Mandibular implant-supported overdenture using CAD-CAM Konus type attachment: A case report)

  • 박종희;김인주;김경아;송광엽;서재민
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.259-266
    • /
    • 2016
  • 하악 완전 무치악 환자의 보철수복에 있어 임플란트 식립 후 피개의치 제작은 첫 번째 치료 옵션으로 고려된다. 코너스 타입 부착장치를 이용한 피개의치는 견고한 지지를 제공하고 cross arch stabilization을 이루도록 하여 교합압을 균일하게 분산시키며, 의치에 의한 이차 고정으로 장기간의 안정성을 제공한다. 최근 소개된 팔라듐-은(Pd-Ag) 합금(Innovium)은 팔라듐, 은, 금 등의 귀금속 함량이 72% 이상인 CAD-CAM 시스템 전용 귀금속 합금으로 코너스 타입 부착장치를 제작하는데 적합한 물성을 가지고 있다. 본 증례에서는 완전 무치악 환자에서 상악에는 통상적인 총의치, 하악에는 임플란트를 4개 식립한 후에 코너스 타입 부착장치 피개의치 수복을 하였다. CAD-CAM 시스템을 이용하여 팔라듐-은 합금(Innovium)으로 제작된 코너스 타입 부착장치를 장착하였으며 이를 통해 의치의 유지와 안정을 향상시켰으며 만족할 만한 결과를 얻었기에 보고하고자 한다.

한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究) (A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA)

  • 장익태;양재호;김창회;김광남;이선형;김영수;장완식
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF