• Title/Summary/Keyword: Paired Comparison Method

Search Result 186, Processing Time 0.025 seconds

Comparison and Evaluation of the Effectiveness between Respiratory Gating Method Applying The Flow Mode and Additional Gated Method in PET/CT Scanning. (PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가)

  • Jang, Donghoon;Kim, Kyunghun;Lee, Jinhyung;Cho, Hyunduk;Park, Sohyun;Park, Youngjae;Lee, Inwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Purpose The present study aimed at assessing the effectiveness of the respiratory gating method used in the flow mode and additional localized respiratory-gated imaging, which differs from the step and go method. Materials and Methods Respiratory gated imaging was performed in the flow mode to twenty patients with lung cancer (10 patients with stable signals and 10 patients with unstable signals), who underwent PET/CT scanning of the torso using Biograph mCT Flow PET/CT at Bundang Seoul University Hospital from June 2016 to September 2016. Additional images of the lungs were obtained by using the respiratory gating method. SUVmax, SUVmean, and Tumor Volume ($cm^3$) of non-gating images, gating images, and additional lung gating images were found with Syngo,bia (Siemens, Germany). A paired t-test was performed with GraphPad Prism6, and changes in the width of the amplitude range were compared between the two types of gating images. Results The following results were obtained from all patients when the respiratory gating method was applied: $SUV_{max}=9.43{\pm}3.93$, $SUV_{mean}=1.77{\pm}0.89$, and $Tumor\;Volume=4.17{\pm}2.41$ for the non-gating images, $SUV_{max}=10.08{\pm}4.07$, $SUV_{mean}=1.75{\pm}0.81$, and $Tumor\;Volume=3.56{\pm}2.11$ for the gating images, and $SUV_{max}=10.86{\pm}4.36$, $SUV_{mean}=1.77{\pm}0.85$, $Tumor\;Volume=3.36{\pm}1.98$ for the additional lung gating images. No statistically significant difference in the values of $SUV_{mean}$ was found between the non-gating and gating images, and between the gating and lung gating images (P>0.05). A significant difference in the values of $SUV_{max}$ and Tumor Volume were found between the aforementioned groups (P<0.05). The width of the amplitude range was smaller for lung gating images than gating images for 12 from 20 patients (3 patients with stable signals, 9 patients with unstable signals). Conclusion In PET/CT scanning using the respiratory gating method in the flow mode, any lesion movements caused by respiration were adjusted; therefore, more accurate measurements of $SUV_{max}$, and Tumor Volume could be obtained from the gating images than the non-gating images in this study. In addition, the width of the amplitude range decreased according to the stability of respiration to a more significant degree in the additional lung gating images than the gating images. We found that gating images provide information that is more useful for diagnosis than the one provided by non-gating images. For patients with irregular signals, it may be helpful to perform localized scanning additionally if time allows.

  • PDF

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

The Improvement of Knowledge and Management Capability of Oral Health according to the Oral Health Education System for Elementary School Students (구강보건교육에 의한 초등학교 학생의 구강보건 지식도와 구강위생관리능력의 변화)

  • Jeon, Hyun-Ja;Song, Keun-Bae;Lee, Sung-Kook
    • Journal of the Korean Society of School Health
    • /
    • v.12 no.2
    • /
    • pp.295-303
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of systemic oral health education on the improvement of knowledge levels and patient hygiene performance(PHP) for elementary school students. The randomly selected 1st and 5th grade students in a public elementary school of Taegu city were divided by education group(118 students) and non-education group(122 students). The oral health education lesson was systematically held on the education group once a month for 4 months. The questionnaire queried all the subjects about their knowledge and attitudes before and after oral health education, and PHP was also tested at the same time. Corresponding p-values were significantly considered at values less than 0.05. The obtained results were as follows: Due to the oral health education lesson, the education group of both 1st and 5th grade students came to have a higher knowledge level than the non-education group. There was high improvement of items such as toothbrushing time, toothbrushing method, cause of dental caries, treatment after tooth damage, and tongue-brushing. Therefore, these items should be educated to all the elementary school students. By increaseing the knowledge level of oral health after education, the PHP index in the education group was significantly decreased in comparison to the non-education group and hence the capability of oral health management improved. From the above results, a systematically and periodically oral health education system for elementary school students can improve the knowledge level and capability of oral health management. Further study will be required to develop an easy and acceptable systemic oral health education program for elementary schools.

  • PDF

Preliminary Study on Actuated Signal Control at Rural Area of Cheon-an City (천안시 외곽지역의 감응식 신호운영을 위한 기초연구)

  • Park, Soon-Yong;Kim, Dong-Nyong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.3
    • /
    • pp.52-63
    • /
    • 2009
  • Recently in Korea, in the case of metropolis, the urban signalized intersections are controlled by traffic information center or ITS center. Cheon-an City also established traffic information center through the 1st.-$\sim$3rd. ITS public construction and has managed this center that includes bus information service, traffic information collection and providing service, parking information service, and traffic responsive control system. In the Cheon-an metropolitan traffic signal operation, traffic signal controllers were grouped by the each main traffic flow axes and performed with coordinated signal timing for the signalized arterials, and also cycle and split changed by realtime traffic demands. Cheon-an urban traffic responsive control system was evaluated by intersection delay and speed, then it was verified that the delay decreased and vehicle speed improved. However, the rural signal control system to connect adjacency town was evaluated to have lower status than urban area due to the unimproved TOD (Time of day) plan. Therefore actuated signal control was examined for substitutive control system in isolated signal intersection. The aim of this article is to compare actuated signal control with TOD mode in the rural intersection of Cheon-an and to fine superiority of these two control mode, with evaluation of vehicle delay by using HCM(2000) method and by micro-simulation CORSlM. The result of field test show that actuated signal control gave better performance in delay comparison than the existing TOD signal control. And simulation outcome verified that non-optimized TOD has higher delay than optimized TOD mode, non-optimal actuated mode, and optimal actuated signal control mode. Particularly, these three modes delays had not different values according to the paired sample t-test. This is because small traffic demands were loaded in each links. This suggested actuated signal control is expected to be more effective than TOD mode in some rural isolated intersections which frequently need to survey for traffic volume.

  • PDF

Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations (두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교)

  • Shin, Ho-Sik;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.528-534
    • /
    • 2008
  • Purpose: Marginal fit is one of the important components for the successful prosthodontic restoration. Poor fitting margin of the restoration causes hypersensitivity, secondary caries, and plaque accumulation, which later result in prosthodontic failure. CAD/CAM zirconia all-ceramic restorations, such as $LAVA^{(R)}$ (3M ESPE, St.Paul, MN) and $EVEREST^{(R)}$ (KaVo Dental GmbH, Biberach, Germany) systems were recently introduced in Korea. It is clinically meaningful to evaluate the changes of the marginal fit of the CAD/CAM zirconia systems before and after build-up. The purposes of this study are to compare the marginal fit of the two CAD/CAM all-ceramic systems with that of the ceramometal restoration, before and after porcelain build-up Material and methods: A maxillary first premolar dentiform tooth was prepared with 2.0 mm occlusal reduction, 1.0 mm axial reduction, chamfer margin, and 6 degree taperness in the axial wall. The prepared dentiform die was duplicated into the metal abutment die. The metal die was placed in the dental study model, and the full arch impressions of the model were made. Twenty four copings of 3 groups which were $LAVA^{(R)}$, $EVEREST^{(R)}$, and ceramometal restorations were fabricated. Each coping was cemented on the metal die with color-mixed Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan). The marginal opening of each coping was measured with $Microhiscope^{(R)}$ system (HIROX KH-1000 ING-Plus, Seoul, Korea. X300 magnification). After porcelain build-up, the marginal openings of $LAVA^{(R)}$, $EVEREST^{(R)}$,and ceramometal restorations were also evaluated in the same method. Statistical analysis was done with paired t-test and one-way ANOVA test. Results: In coping states, the mean marginal opening for $EVEREST^{(R)}$ restorations was $52.00{\pm}11.94\;{\mu}m$ for $LAVA^{(R)}$ restorations $56.97{\pm}10.00\;{\mu}m$, and for ceramometal restorations $97.38{\pm}18.54\;{\mu}m$. After porcelain build-up, the mean marginal opening for $EVEREST^{(R)}$ restorations was $61.69{\pm}19.33\;{\mu}m$, for $LAVA^{(R)}$ restorations $70.81{\pm}12.99\;{\mu}m$, and for ceramometal restorations $1115.25{\pm}23.86\;{\mu}m$. Conclusion: 1. $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations in comparison with ceramometal restorations showed better marginal fit, which had significant differences (P < 0.05) in coping state and also after porcelain build-up . 2. The mean marginal opening values between $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations did not showed significant differences after porcelain build-up as well as in coping state (P > .05). 3. $EVEREST^{(R)}$, $LAVA^{(R)}$ and ceramometal restorations showed a little increased marginal opening after porcelain build-up, but did not show any statistical significance (P > .05).