• Title/Summary/Keyword: Paddle speed

Search Result 12, Processing Time 0.019 seconds

Effects of Paddle Wheel on Water Circulation in Shrimp Culture Ponds (축제식 대하양식장에서 수차의 순환기능)

  • 강윤호
    • Journal of Aquaculture
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2001
  • To study the effect of paddle wheel on water circulation, velocity components were measured in shrimp ponds both along the longitudinal direction from a single paddle wheel and at 25 grid points of two ponds, which have mean water depth of 1.2m and aspect ratio (length/width) 1.05 and 0.68, respectively. An analysis of factors related to water quality and circulation showed that I) a single paddle wheel has an effective distance of 33m for de-stratification, 16m for particulate suspension and 25m for removal of organic material, dispersion of DO and prevention of bed sediment disturbance and ii) with doubling the number of paddle wheels at the pond corners, the flow speed increased by 13% over the ponds, while it reduced by 8.5% around the pond centres. Contrary to expectation, increasing the number of paddle wheel did not generate strong circulation around the pond centre and improve water quality.

  • PDF

Solid-Liquid Mass Transfer in Gas-Solid-Liquid 3-Phase System Agitated Vessel (기 - 액 - 고 3상계 교반조내의 고-액간 물질이동)

  • Lee, Young Sei;Kato, Yoshihito;Suzuki, Junichiro
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.509-516
    • /
    • 2006
  • The solid-liquid mass transfer coefficients $k_L$ in a gas-liquid-solid three phases agitated vessel were measured with conventional impellers (e.g. Rushton turbine, paddle, and propeller). For the conventional impellers the rotational speed for the complete suspension $N_{js}$ changes with the impeller height and gas flow rate. Mass transfer coefficient of the Rushton turbin impeller, for which the particle suspension was independent of the aeration, is correlated only with Pgv. Mass transfer coefficients $k_L$ for the Rushton turbine, paddle and propeller impellers were affected by the impeller position.

CFD ANALYSIS ON THE CHARACTERISTICS FOR FLOCCULATORS OF VERTICAL PADDLE AND HYDRO-FOIL TYPE (수직 패들형 및 하이드로 포일형 응집기 특성의 전산유체역학 해석)

  • Shin, J.H.;Chang, S.M.;Cho, Y.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.24-30
    • /
    • 2016
  • In the water purification plant, the mixture of water and chemical from the mixing basin enters the flocculation basin. The rotating flocculators are generally used for the efficient flocculation of dregs. In this paper, the performance of flocculators of a vertical paddle type, widely used in the typical flocculation basins, and a hydro-foil type, recently disseminated in the field, are compared with each other by use of the numerical method. Also the characteristics and the efficiency are analyzed with CFD techniques. The strain rate and the eddy viscosity are compared for two types to predict the mixing efficiency, and the maximum speed and its location are pursued from the computed data. The hydrofoil type shows that the eddy viscosity is enhanced 1.66 to 3.03 times larger than that of vertical paddle type, and also produced 1.87 to 1.95 times larger flocs for each stage. However, the rapid rotation of hydrofoil may chop the floc to small size due to the higher turbulence intensity. From the result of computation, the strong and weak points of each type have been analyzed for the decision making.

A Study on Measurement and Automation Method of Cylinder Head Swirl (실린더 헤드 스월 측정 및 자동화 방법에 관한 연구)

  • Lee Choong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

Effect of Mixing Pattern of Different Types of Bioreactor on Enzymatic Hydrolysis of Cellulose (각종 섬유질 효소당화 반응조내의 현탁액의 혼합교반양상이 효소당화에 미치는 영향)

  • 박진서;박동찬이용현
    • KSBB Journal
    • /
    • v.4 no.3
    • /
    • pp.221-228
    • /
    • 1989
  • Celluose is an insoluble substrate, therefore, a proper mixing of the cellulose suspension is essential for an effective enzymatic hydrolysis. To study the effect of mixing motion of various enzyme reactors on enzymatic hydrolysis of cellulose, three distinct types of biroreator: vertical impeller type bioreator(VITB), horizontal paddle type bioreactor(HPTB), and tumbling drum type bioreactor(TDTB), were assembled and their performance was compared. The optimal agitation speed was 100rpm for VITB and HPTB, 200rpm for TDTB. The saccharification efficiency of each reactor was compared under the optimal agitation intensity. The highest degree of saccharification was achieved in the case of VITB, especially, at high cellulose concentration. The VITB seems to be the most suitable type of bioreactor that can maintain proper mixing pattern for effective enzyme reaction. In the view of energy consumption, the TDTB showed the lowest value: however, the energy consumption was rapidly increased at high concentration of celluose. To dertermine the most suitable type of bioreactor, the entire process, including substrate cost, substrate concentration, and feasibility of scale-up, needs to be evaluated.

  • PDF

Preparation and Release Characterization of Osmotic Granule Nifedipine Delivery System (니페디핀 삼투성 과립 시스템의 제조와 약물 방출 특성)

  • Jeong, Sung-Chan;Cho, Young-Ho;Lee, Soo-Young;Lee, Bong;Kim, Moon-Suk;Kang, Gil-Son;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2006
  • The objective of this study was to confirm the effect of the type of dissolution media and paddle speed on nifedipine (ND) release profile from osmotic granule and the storage stability. Osmotic granule was manufactured by fluidized bed coating method. At each coating step, morphology of osmotic granule was differed. The size of osmotic granule was $750\;{\mu}m$ at 3 wt% membrane thickness. ND release was changed in diverse dissolution media, paddle speed. ND release is governed by not only osmotic pressure but diffusion from osmotic granule. ND release from osmotic granule decreased as storage period increased. These may be caused by liquid excipient which has low molecular weight. Storage stability of osmotic granule could be improved by removing liquid excipient from semipermeable membrane.

A Study on the Automatic Measurement of Swirl Generated fi:om Intake Port of Engine Cylinder Head Using an I-IEEE-1394 Camera and Step Motors (IEEE-1394카메라와 스텝모터를 이용한 엔진 실린더헤드의 흡기포트 스월 측정 자동화에 관한 연구)

  • Lee Choong-Hoon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.88-94
    • /
    • 2005
  • A swirl ratio of a charge in the cylinder could be calculated by measuring both the rotary speed of paddle and the intake air flow rate in the swirl measurement apparatus fur several positions of valve lift. The automation of the swirl ratio measurement for a cylinder head is achieved by controlling both the valve lift of cylinder head and a suction pressure of the surge tank, instead of controlling them manually. PID control of the surge tank pressure and positioning a valve lift of the cylinder head are also achieved by using two step motors, respectively. Rotating speed of a paddle are measured using an optical sensor and a counter. Flow rate are measured from ISA 1932 flow nozzle by reading a differential pressure gauge position using IEEE-1394 camera. Time to measure the swirl ratio for a port in the cylinder head is drastically reduced from an hour to 3 minutes by automation control of the apparatus.

Development of the Dissolution Test for Dobesilate Calcium Tablets and Acepifylline Tablets (도베실산칼슘 정 및 아세피필린 정의 용출시험법 개발)

  • Park, Chan-Ho;Lee, Jin-Ha;Kim, Eun-Jung;Sohn, Kyung-Hee;Kim, Young-Ok;Kim, Dong-Sup;Song, Young-Me;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.131-137
    • /
    • 2011
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for dobesilate calcium tablets and acepifylline tablets. These drugs were not yet characterized by the dissolution specifications in Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for dobesilate calcium tablets was carried out under sink conditions as following: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 30 min in this method. Also the dissolution test for acepifylline tablets was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 45 min in this method. The dissolution samples were analyzed with a precise and accurate HPLC method. The developed dissolution test showed specificity, linearity, precision and accuracy within the acceptable range. The dissolution testing method described above was adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of dobesilate calcium tablets and acepifylline tablets.

Transient Simulation of Solid/Liquid Two-Phase Flow in a Stirred Tank (교반기 내부의 고체/액체 다상 유동의 비정상상태 해석)

  • Kim, Chi-Gyeom;Yong, Suk-Jin;Won, Chan-Shik;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.236-239
    • /
    • 2008
  • In the present study, a transient glass particle distribution in a stirred solid/liquid mixer was investigated using computational fluid dynamics(CFD). The flow patterns and solid concentaration distriburion in a solid/liquid mixer formed by pitched paddle and baffles were predicted. The numerical results were compared to experimental data from the available literature. Eulerian multi-phase model was used to investigate the influence of the density of solid particle on the same impeller speed. A good agreement was obtained between the experimental data and simulation results.

  • PDF

Development of the Dissolution Test for Viquidil Hydrochloride Capsules and Alibendol Tablets (염산비퀴딜 캡슐 및 알리벤돌 정의 용출시험에 관한 연구)

  • Hwang, Joung-Boon;Koo, Eun-Joo;Go, Seu-Youn;Cho, Kyung-Chul;Moon, Hyun-Ju;Cho, Soo-Yeul;Kang, Chan-Soon;Shon, Yeo-Won;Kim, Young-Ok;Sohn, Kyung-Hee;Cho, Dae-Hyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.348-353
    • /
    • 2010
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for viquidil hydrochloride capsules and alibendol tablets. These drugs were not yet characterized by the dissolution specifications in Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for viquidil hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 30 min in this method. Also the dissolution test for alibendol tablets was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 45 min in this method. The dissolution samples were analyzed with a precise and accurate HPLC method. The developed dissolution test showed specificity, linearity, precision and accuracy within the acceptable range. The dissolution testing method described above was adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of viquidil hydrochloride capsules and alibendol tablets.