• Title/Summary/Keyword: Pad Transformer

Search Result 23, Processing Time 0.022 seconds

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign (국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong;Lee, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

Evaluation of Adhesiveness with Current Flow Time in the Indirect Heating of an Asphalt Pad using Joule Heating (줄 히팅을 이용한 아스팔트패드 간접가열에 있어서 통전시간별 융착성 평가)

  • Bae, Ki-Man;Choi, Han-Suk;Oh, Bo-Ra-Mi;Baek, Jong-Jin;Park, Seong-Hwan;Kang, Myungchang;Lee, Jae-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.8
    • /
    • pp.104-109
    • /
    • 2020
  • Recently, vibration and noise have become an important issue in the auto industry. Asphalt vibration damping pads are used to reduce the noise and vibration of automobile bodies, and asphalt is used for many mass-produced parts due to its simple attachment process and low processing costs. In this study, the self-adhesion of asphalt pads using Joule heating was evaluated. To create the asphalt pad for the experiment, the asphalt pad was molded into a specific thickness by using SGACC material and rubber used in the vehicle body as a main component and a modified resin and filler. The SGACC material was 200 mm in length, 200 mm in width, and 0.7 mm in thickness. The asphalt pad was 200 mm in length, 100 mm in width, and 3 mm in thickness. The equipment was composed of a TR (Transformer) DC254kVA and a TC (Time controller) for a current of up to 20,000 A. The current for the Joule heating was set to 7.0 kA and a 3/1 cycle, for which the adhesion of the asphalt pad over the current flow time was evaluated.

A Study on Diagnosis for Pole and Pad Transformers using Wireless Data Communication (무선데이터 통신을 이용한 주상 및 지상 변압기 진단에 관한 연구)

  • Min, Kyeong-Rae;Jeon, Yong-Joo;Yoon, Yong-Han;Kim, Jae-Chul;Choi, Do-Hyuk;Kim, Young-Chun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1431-1433
    • /
    • 1999
  • In this paper, we present diagnosis system for pole and pad transformers using wireless data communication. This system used radio frequency modem for communication between transformer and mobile car. We studied communication's protocol and data frames for operating diagnosis system of distribution transformers

  • PDF

Performance Comparison of Transmitter and Receiver Pad in Inductive Power Transformer for Drones (드론용 무선 전력전송 시스템에 알맞은 송·수신 패드 성능 비교)

  • Kim, Sung;Na, Hyeong-Uk;Jo, Cheol-Hee;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.220-221
    • /
    • 2019
  • 본 논문에서는 자기유도방식의 드론용 무선전력 전송 시스템에 적합한 송·수신 패드의 모델을 제안하고, 드론의 수평 이격 거리에 따른 특성을 비교하였다. 송·수신 코일 간 결합계수, 저항 성분 등을 통하여 송·수신 패드의 성능을 비교하였으며, 해당 모델에서 최적의 성능을 보이는 코일의 턴 수 및 위치를 연구하였다.

  • PDF

A Study on the Soundproofing Plate Techniques for Noise Reduction of Power Transformers (전력용 변압기 소음저감을 위한 차음판 기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chon;Kim, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.47-55
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an enclosure to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. To shut out sound emitted from transformers, we developed a soundproof technology that wall up reinforcing bar by steel sheet. For the practical application of it, we analyzed the vibration characteristics of a transformer tank and reduction of noise according to soundproof plate. As a result, it is confirmed that the technology can reduce 11 [dB] of transformer noise.

Finite Element Analysis of Internal Winding Faults in PAD-Type Distribution Transformer (유한요소법을 이용한 배전용 PAD변압기 권선고장시의 전자계해석)

  • Ha, Jung-Woo;Kim, Chul;Kim, Han-Deul;Shin, Pan-Seok;Lee, Byung-Sung;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.108-110
    • /
    • 2005
  • 배전용 변압기의 경우 고장 발생시 직접적인 수용가 측에 피해가 발생되며, 변압기 폭발시 인명 피해까지 우려되고 있다. 변압기 내부 고장으로 절연유가 분출될 경우가 가장 심각한 고장으로 이러한 피해를 방지하기 위해서는 내부 고장에 대한 정확한 해석이 필요하다. 본 연구에서 변압기 권선내에서 발생되는 고장을 유한요소 전자계해석 프로그램(FLUX2D)을 이용하여 해석하였다. 50kVA, 13200/230(V) 단강 변압기의 권선고장시 전자계해석, 1차측 권선고장(turn-to-earth)과 2차측 권선고장(turn-to-turn)을 모의하여 해석하였다. 또한, 권선 내부 고장 및 2차측 단락시 누설자속분포, 1차 및 2차측 고장전류, 권선간의 힘의분포 등을 해석하였다. 분석결과는 변압기의 절연설계 및 단락기계력에 대한 프레임 구조 설계를 위한 자료로 활용된다.

  • PDF

The Study of Comparison of the Symmetrical Short Circuit Test Current with ANSI/IE Transformers. (변압기의 단락강도 시험 시 ANSI와 IEC 규격에 의한 시험 전류의 비교 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jeong, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.694-696
    • /
    • 2002
  • Transformers together with all equipment and accessories shall be designed and constructed to withstand the mechanical and thermal stresses produced by external short circuit which include three phase, single line-to-ground, double line-to-ground and line-to-line faults etc. Generally the Short Circuit Test of transformers is tested according to the ANSI/IEEE, IEC/JEC, KS etc, in domestic. In this study, it will be showed and compared the difference of symmetrical current for short circuit test of a Pad -mounted transformer according to with ANSI /IEEE and IEC.

  • PDF

Improvement of Case Design for Underground Power Distribution Facilities (지중배전기기용 외함 디자인 개선)

  • Jeong, Yeon-Ha;Park, Chul-Bae;Chun, Sung-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.362-365
    • /
    • 2007
  • In this paper we present development process and results of some cases for underground pad transformer and switchgear. Some characteristic factors was considered and tested to improve the functions of the case, such as natural convection of cooling air between the internal and external cases, properties of material that used as external panel etc. Proposed designs and functional characteristics will be adapted to making the cases of underground facilities after the elaborated tests. The results obtained from this study will improve the scenery of a street.

  • PDF

Development target of intelligent DAS with the function of distribution transformer monitoring (배전변압기 감시제어 기능이 통합된 지능형 배전자동화 시스템 개발 방향)

  • Ha, Bok-Nam;Seol, Lee-Ho;Park, Shin-Yeol;Jeong, Yeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.554-556
    • /
    • 2005
  • Distribution Automation System (DAS) will provide supervision and remote control of switches and reclosers such as pole pounted switches and pad-mounted switchgears on high voltage distribution line. Kepco had developed basic function such as remote monitoring, remote control, remote measuring and remote setting at first. As a next step, Kepco has been developed diverse application programs such as single line diagram drawing program, relay coordination program, feeder reconfiguration program, over load elimination program, bad data detection program, section load management program, fault processing program and so on. Kepco is examining to develop more powerful functions for special specification of foreign distribution automation system. This paper explains what is the target for overseas DAS market.

  • PDF