• Title/Summary/Keyword: Packing system

Search Result 365, Processing Time 0.026 seconds

A Study on Drying Kinetics of Low Rank Coal(Indonesia-IBC) through the Fixed-Bed Reactor Experiments (저등급석탄(低等級石炭)(인도네시아 IBC)의 고정층(固定層) 반응기(反應器) 실험(實驗)을 통한 건조(乾操) 반응속도론(反應速度論) 연구(硏究))

  • Kang, Tae-Jin;Jeon, Do-Man;Jeon, Young-Sin;Kang, Suk-Hwan;Lee, Si-Hyun;Kim, Sang-Do;Kim, Hyung-Taek
    • Resources Recycling
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2010
  • The crisis of energy gives rise to the growing concerns over continuing uncertainty in the energy market. Under these circumstances, there are also increasing interests on coals. In particular, Low Rank Coal (LRC) is receiving gradual attentions from green industry. But due to is high moisture content range from 30 - 60%, drying process has to be preceded before being utilized as power plant. In this study drying kinetics of LRC is induced by using a fixed-bed reactor. The drying kinetics was evaluated in from of the particle size, the inlet gas temperature, the drying time, the gas velocity, and the LID ratio. The consideration of the reynold's number was taken for correction of gas velocity, particle size and LID was taken for correction of reactor diameter, packing height of coal. As being seen as characteristic of drying coal, it can be found that fixed-bed reactor can contributed to active drying of free water. In this sense, it could be considered that phase boundary reaction is appropriate mechanism.

Electrochemical Characterization of Porous Graphene Film for Supercapacitor Electrode (다공성 그래핀 필름의 슈퍼캐패시터 전극용 전기화학적 특성)

  • Choi, Bong Gill;Huh, Yun Suk;Hong, Won Hi
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.754-757
    • /
    • 2012
  • In this report, we fabricate the porous graphene films through embossing process and vacuum filtration method and demonstrate their superior electrochemical properties as supercapacitor electrode materials. Insertion/removal of polystyrene nanoparticles between the graphene sheets allows to provide pore structures, leading to the effective prevention of restacking in graphene films. As-prepared porous graphene films have a large surface area, a bicontinuous porous structures, high electrical conductivity, and excellent mechanical integrity. The electrochemical properties of the porous graphene films as electrode materials of supercapacitor are investigated by using aqueous $H_2SO_4$ and ionic liquid solution under three-electrode system. The porous graphene films exhibit a high specific capacitance (284.5 F/g), which is two-fold higher than that of packing graphene films (138.9 F/g). In addition, the rate capability (98.7% retention) and long-term cycling stability (97.2%) for the porous graphene films are significantly enhanced, due to the facilitated ion mobility between the graphene layers.

Risk Factors Related to Photo Couplers(P/C) for Signal Transmission by Electronic Devices (전자기기의 신호전송을 위한 Photo Couplers(P/C) 의 위험 요소 발굴)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.26-30
    • /
    • 2013
  • The purpose of this study is to find risk factors by analyzing the operation principle of a photo coupler (P/C) used to remove the noise of electronic devices and establish a base for the performance improvement of developed products. It was found from the P/C circuit analysis of normal products that they were equipped with an electrolytic condenser of $0.1{\mu}F$ to smooth system signals. Due to the epoxy resin packing the external part of the P/C, this study experienced a limit to visually examine the damage to it. It could be seen from the analysis of electric characteristics of the P/C that the forward voltage ($V_f$) and reverse current ($I_r$) were 1.3 V and 10 uA, respectively. In addition, it is required that the breakdown voltage (VCE) between the collector (C) and emitter (E) be maintained at less than 35 V. The and of the damaged product #1 were comparatively good. However, the measurement of was 100.0 uA. From this, it is thought that a short circuit occurred to the internal circuit. Moreover, from the fact that the of the damaged product #2 was open circuit and the measurement of was 0.0 uA, it is thought that the collector and emitter was separated or insulation resistance was significantly high. Furthermore, from the fact that the of the damaged product #3 was open circuit and the measurement of was 0.0 uA, it is thought that the space between the collector (C) and emitter (E) failed to meet the design standard or that they were separated. Therefore, it is thought that fabricating the P/C by increasing the reverse current 10 mA to 50 mA will prevent its malfunction.

An Experimental Study on the Toluene Control Characteristics of Biofilter Packed with Compost, Peatmoss and GAC (Compost, Peatmoss, GAC의 복합 메디아로 충전된 Biofilter의 Toluene 제어특성에 관한 실험적 연구)

  • Eom, Yun-Sung;Han, Se-Hyun;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.265-276
    • /
    • 2007
  • The primary objective of this study is to investigate the effect of media on the performance of biofilters. Two types of experiments were carried out in this study. The first type of experiment used a biofilter with the media composed of three different packing materials of compost, peatmoss and GAC(granular activated carbon), whereas the second type used a biofilter with the media composed of compost only. It was found from the two experiments that the biofilter composed of compost, peatmoss and GAC showed better performance than the one composed of compost only with the higher toluene removal efficiency, lower pressure drop, and more uniform media moisture content. In particular, no appreciable media compression occurred for the biofilter composed of compost, peatmoss and GAC, whereas significant media compression took place in the biofilter composed of compost only. As suggested by the other researchers, it is likely that GAC may be responsible for the higher toluene removal efficiency in the case of the biofilter composed of mixed media especially for the early stage of biofiltration due to its adsorption capability of toluene of such high concentration as 300 ppm. It was also regarded that GAC may playa major role in maintaining lower media pressure drop in the case of the mixed media than the media with compost only because of its mechanical strength resisting to the compression. Nonetheless, further refined experiments may need to draw more accurate conclusion. The results of the additional test run using the same mixed media showed that the biofilter system using the mixed media can be consistently operated for more than 100 days very stably despite sudden change in operating conditions of temperature and flow rate.

A New Sampling and SEC Method for Analysis of Underivatized Cellulose (셀룰로스의 분석을 위한 새로운 시료처리 및 크기배제크로마토그래피)

  • Lee, Seung Ho;Park, Hee Young
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.2
    • /
    • pp.190-196
    • /
    • 1998
  • A new sampling and size exclusion chromatography (SEC) method for the analysis of underivatized cellulose are established. In this method, cellulose materials are first dissolved in N-methylmorpholine N-oxide (NMMO) and diluted by adding dimethyl sulfoxide (DMSO) to make the sample solutions of about 0.1% in 50/50 NMMO/DMSO (w/w). Sample solutions are analyzed using a glucose-treated divinylbenzene (DVB) SEC column and DMSO containing 0.05M LiBr and 2.5 blank as the eluant. The flow rate was constant at 1 mL/min and the whole SEC system including the column was heated at $80^{\circ}C$ to reduce the viscosity of DMSO. Addition of 0.05 M LiBr eliminated SEC baseline drifting, and addition of 2.5 blank seems to reduce the interaction between the sample and the column packing. SEC molecular weights were determined using a calibration curve constructed from a series of narrow pullulan standards, and they were used to measure the degree of degradation during two different pulp-to-sponge processings.

  • PDF

Method of Signature Extraction and Selection for Ransomware Dynamic Analysis (랜섬웨어 동적 분석을 위한 시그니처 추출 및 선정 방법)

  • Lee, Gyu Bin;Oak, Jeong Yun;Im, Eul Gyu
    • KIISE Transactions on Computing Practices
    • /
    • v.24 no.2
    • /
    • pp.99-104
    • /
    • 2018
  • Recently, there are increasing damages by ransomware in the world. Ransomware is a malicious software that infects computer systems and restricts user's access to them by locking the system or encrypting user's files saved in the hard drive. Victims are forced to pay the 'ransom' to recover from the damage and regain access to their personal files. Strong countermeasure is needed due to the extremely vicious way of attack with enormous damage. Malware analysis method can be divided into two approaches: static analysis and dynamic analysis. Recent malwares are usually equipped with elaborate packing techniques which are main obstacles for static analysis of malware. Therefore, this paper suggests a dynamic analysis method to monitor activities of ransomware. The proposed method can analyze ransomwares more accurately. The suggested method is comprised of extracting signatures of benign program, malware, and ransomware, and selecting the most appropriate signatures for ransomware detection.

Research on Heat and Mass Transfer Coefficient in the Packing Layer With a Solar Desiccant Heating/Cooling System (태양열 데시컨트 냉난방시스템 중 충진층에 있어서의 열 물질전달에 관한 연구)

  • Yohana, Eflita;Choi, Kwang-Hwan;Kim, Bu-Ahn;Kim, Dong-Gyu;Paek, Ki-Dong;Kim, Ji-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.17-24
    • /
    • 2006
  • 최근에 에너지절약 차원에서 종래의 공조방식을 대신할 새로운 냉난방시스템 개발이 요구되고 있는데, 본 논문에서는 태양열 집열기를 이용하는 데시컨트 시스템 중 제습역할을 실질적으로 담당하는 제습기의 충진층 부분에서의 열 및 물질전달에 관한 일련의 해석 결과를 발표하고 있다. 제습과정에서 액체흡수제는 충진층에서 열 뿐만 아니라 물질전달을 수반하게 되는데, 이 결과 건물에 냉방 및 난방효과를 가져다 준다. 따라서 이 충진층의 최적 설계가시스템의 효율을 극대화하기 위해서는 무엇보다도 중요한데, 이를 위해서는 충진층에서의 열 및 물질전달 양상을 규명하여야 한다. 따라서 금번 실험에서는 공기와 액체흡수제와의 접촉면적을 넓히기 위해서 충진재로써 3cm(직경) ${\times}$ 3cm(높이)인 시판중인 플라스틱 재질을 사용하고, 실질적으로 40cm(너비)${\sim}$40cm(깊이)${\times}$40cm(높이)의 충진층을 직접 제작하여 실험을 행하였다. 그 결과, 공기측 열 및 물질전달 계수는 공기 온도와 밀접한 관계를 갖고 있으며, 또한 물질전달계수는 열전달계수와 같은 경향을 보이고 있음을 알 수 있었다.

Optimal Design of the Safety Valve by Response Surface Method (반응표면법을 이용한 안전밸브의 최적화)

  • Lee, Sang-Woo;Shin, Dae-Young;Byun, Cheol-Woong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.551-556
    • /
    • 2007
  • High pressure storage of the agent gas in fire suppression system was composed of tank, main valve and safety valve, which prevents the fracture of the high pressure storage. The safety valve has circular thin plate as fracture plate that was destroyed over fracture pressure. When inner pressure of the storage is reached the fracture pressure, the safety valve discharges gas and degrades simultaneously the inner pressure of the storage. There are design variables such as flow path diameter, inner diameter of the plastic packing ring, thickness of plate and fillet radius. In this variables, thickness of plate is set to be a value of 0.2mm. The main effect of variables on the inner pressure, has been decided using factorial design and statistical analysis. Therefore, the relation of variables are expressed by regression equation. It is disclosed results that the difference of fracture pressures between the equation and experiment has $2{\sim}5%$. Finally, using response surface method, the optimal design of the safety valve could be decided with safety pressure of 25MPa, where the fracture occurs on circular thin plate.

Pericardial Tamponade following Perihepatic Gauze Packing for Blunt Hepatic Injury (둔상성 간손상 환자의 손상 통제술 후 발생한 심낭압전)

  • Ye, Jin Bong;Sul, Young Hoon;Go, Seung Je;Kwon, Oh Sang;Kim, Joong Suck;Park, ang Soon;Ku, Gwan Woo;Lee, Min Koo;Kim, Yeong Cheol
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.211-214
    • /
    • 2015
  • The primary and secondary survey was designed to identify all of a patient's injuries and prioritize their management. However 15 to 22.3% of patient with missed injuries had clinically significant missed injuries. To reduce missed injury, special attention should be focused on patients with severe anatomical injury or obtunded. Victims of blunt trauma commonly had multiple system involvement. Some reports indicate that inexperience, breakdown of estalished protocol, clinical error, and restriction of imaging studies may be responsible for presence of missed injury. The best way of reducing clinical significant of missed injuries was repeated clinical assessment. Here we report a case of severe blunt hepatic injury patient and pericardial injury that was missed in primary and secondary survey. After damage control surgery of hepatic injury, she remained hemodynamically unstable. Further investigation found cardiac tamponade during intensive care. This was managed by pericardial window operation through previous abdominal incision and abdominal wound closure was performed.

  • PDF

Morphological study on effect of radiation in developing mouse brain after fetal exposure (태아시기의 방사선 노출에 의한 마우스 뇌 발달에 미치는 영향에 관한 형태학적 연구)

  • Lee, Jong-hwan;Oh, Heon;Kim, Se-ra;Lee, Hae-june;Kim, Tae-hwan;Lee, Yun-sil;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.395-400
    • /
    • 2001
  • The present study analyze the morphological aspects of the cerebrum of mice with prenatal exposure to high and low dose (0.5, 1, 2 Gy) of $\gamma$-radiation on gestation day 12 or 16. The animal were allowed to give birth and the offspring were sacrificed at postnatal days 28 for gross and microscopic examination of cerebrum. Their body weight, brain weight, brain length, brain width, cortical thickness and area of cingulum bundle were examined. The histological and planimetric analysis were performed observing coronal sections. The gross malfomation (microcephaly) and abnormality of cortical architecture were prominent after exposure to 2 Gy on day 12 of gestation. significant dose-related reductions in body weight, brain weight, brain size were found in all irradiated groups. A significant change was found in thickness of the cerebral cortex and area of the cingulum bundle in the groups exposed to 0.5 Gy or more. There was no difference a lamina patter of six layers in cerebral cortex between the control and irradiated groups, but cell packing density increased significantly in the group exposed to 1 Gy or more. These results suggested that dose as low as 0.5 Gy could cause a morphologically reduce change in developing mouse cerebrum and exposure on day 12 of gestation to $\gamma$-irradiation is a particularly sensitive phase in causing malformation and abnormality of central nerve system.

  • PDF