• 제목/요약/키워드: Packing Group

검색결과 141건 처리시간 0.029초

근적외선 분광광도법을 이용한 PVC포장재 중 DEHP 정량법에 관한연구 (A method for quantitative analysis of DEHP in PVC packing material by Near-Infrared Spectroscopy)

  • 김재관;윤미혜;박포현;김기철
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.61-67
    • /
    • 2002
  • NIRS(Near infrared spectroscopy) scanning from 1300nm to 2400nm was appl ied for the DEHP(di-(2 ethylhexyl)phthalate) in PVC(polyvinyl chloride_packing material. All samples were devided into calibration group and validation group. As a result of conduction the multiple regression analysis on the correlation between the NIR spectrum data and chemical assay value obtained by the Korea Food Sanitation Act. The validation model for measuring the DEHP content had R of 0.997, SEC of 0.132, SEP of 0.176 by MLR and R of 0.996, SEC of 0.142, SEP of 0.198 by PLS and the detection limit was 0.1%. The obtained results indicate that the NIR procedure can potentially be used as a nondestructive analysis method for the purpose of rapid and simple measurement of DEHP in PVC packing material.

반나절 비강충전이 비골 골절 수술결과에 미치는 영향 (The Effect of Half Day Nasal Packing in Results of Closed Reduction of Nasal Bone Fracture)

  • 한동길;김태섭
    • 대한두개안면성형외과학회지
    • /
    • 제13권2호
    • /
    • pp.119-124
    • /
    • 2012
  • Purpose: Closed reduction and nasal packings for 3-7 days is usual procedures in managing nasal bone fracture. Most patients experience several discomfort owing to lack of nasal breathing. There are many reports concerning how to reduce patient's discomforts or complications. But it is obvious that the duration of nasal packing is 3-7 days. The aim of this study is evaluate the effect of half day nasal packing in results of nasal bone fracture. Methods: The study was performed on 97 nasal bone fracture patients who had simple nasal bone fractures from January to June 2012. The incidence, cause, patient's discomfort and satisfaction with half day nasal packing are analyzed according to patient's medical records and questionnaire at each nasal packing removal, postoperative 4 weeks. Results: Young male patients, especially the teenagers and the twenties were the common age group, and physical violence was most common cause of injury. A total of 78 out of 97 patients were male. In 92 cases, closed reduction were applied. Approximately, 87% of the patients were satisfied with the outcomes. Conclusion: Half day nasal packing is considered as an effective method to minimize patient's discomfort owing to prolonged absence of nasal breathing with maintenance of stability.

A Capillary Electrochromatographic Microchip Packed with Self-Assembly Colloidal Carboxylic Silica Beads

  • Jeon, In-Sun;Kim, Shin-Seon;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권4호
    • /
    • pp.1135-1140
    • /
    • 2012
  • An electrochromatographic microchip with carboxyl-group-derivatized mono-disperse silica packing was prepared from the corresponding colloidal silica solution by utilizing capillary action and self-assembly behavior. The silica beads in water were primed by the capillary action toward the ends of cross-patterned microchannel on a cyclic olefinic copolymer (COC) substrate. Slow evaporation of water at the front of packing promoted the self-assembled packing of the beads. After thermally binding a cover plate on the chip substrate, reservoirs for sample solutions were fabricated at the ends of the microchannel. The packing at the entrances of the microchannel was silver coated to fix utilizing an electroless silver-plating technique to prevent the erosion of the packed structure caused by the sudden switching of a high voltage DC power source. The electrochromatographic behavior of the microchip was explored and compared to that of the microchip with bare silica packing in basic borate buffer. Electrophoretic migration of Rhodamine B was dominant in the microchip with the carboxyl-derivatized silica packing that resulted in a migration approximated twice as fast, while the reversible adsorption was dominant in the bare silica-packed microchip. Not only the faster migration rates of the negatively charged FITC-derivatives of amino acids but also the different migration due to the charge interaction at the packing surface were observed. The electrochromatographic characteristics were studied in detail and compared with those of the bare silica packed microchip in terms of the packing material, the separation potential, pH of the running buffer, and also the separation channel length.

Effects of the Nitrile Group Substitution on the Gas Separation Properties of Aromatic Polyamide Membranes

  • Park, Ho-Seung;Jo, Won-Ho;Oh, Tae-Jin;Kang, Yong-Soo;Park, Hyun-Chae
    • Fibers and Polymers
    • /
    • 제1권2호
    • /
    • pp.111-115
    • /
    • 2000
  • The effects of nitrile group substitution onto aromatic polyamide backbone on the gas permeability and permselectivity of the polymers are examined. The gas permeability of aromatic polyamides increase with increasing the content of nitrile group substitution, whereas the permselectivity decreases with increasing the nitrile group contents. The effects of chain linrearity on the permeability and permselectivity are also examined. The non-linearity of the polymers increases the permeability. These behaviors are interpreted in terms of chain packing and crystallinity of the aromatic polyamides.

  • PDF

A prospective randomized trial of xylometazoline drops and epinephrine merocele nasal pack for reducing epistaxis during nasotracheal intubation

  • Patel, Sonam;Hazarika, Amarjyoti;Agrawal, Prachi;Jain, Divya;Panda, Naresh Kumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권4호
    • /
    • pp.223-231
    • /
    • 2020
  • Background: The most frequent complication of nasotracheal intubation (NTI) is epistaxis. Epinephrine nasal gauze packing has been used conventionally as a pre-treatment for reducing epistaxis, but it carries a disadvantage of pain and anxiety in patients. However, xylometazoline drops are easier to administer and more convenient for patients. We aimed at comparing the effectiveness of xylometazoline drops and epinephrine merocele packing in reducing bleeding and postoperative complications in our population. Methods: Our study enrolled 120 patients in a double-blind randomized controlled trial. We randomly allocated ASA1 or 2 adult patients into 2 groups: Group X and Group E. Group X received 0.1% xylometazoline nasal drops, and epinephrine (1:10,000) merocele nasal packing was used in Group E. The primary outcome was the incidence of bleeding during NTI; the severity of bleeding, navigability, bleeding during extubation, and postoperative complications were secondary outcomes. We used IBM SPSS and Minitab software for statistical analysis, and P < 0.05 was considered statistically significant. Results: We analyzed the data of 110 patients: 55 in Group X and 55 in Group E. The two groups did not have different bleeding incidence (56.4% vs 60.0%; P = 0.70); however, the incidence of severe bleeding was less with xylometazoline than with epinephrine (3.63% vs 14.54%; P < 0.05). We also observed less bleeding during extubation (38.2% vs 68.5%; P < 0.05) with xylometazoline. Other secondary outcomes were akin to both groups. Conclusion: The incidence of severe and post-extubation bleeding was significantly less with xylometazoline. Hence, it may be an effective alternative for reducing the incidence and severity of epistaxis during NTI.

$NO_2$-BAP 감광기를 갖는 광중합체의 감광특성에 관한 연구 (A Study on the Photosensitivities of Nitro Substituted Benzalacetophenone Group)

  • 유승렬
    • 한국인쇄학회지
    • /
    • 제9권1호
    • /
    • pp.12-26
    • /
    • 1991
  • Packing in printing work os caused by mutual relations with trapping, ink and damping water, or by the expansion and contraction in the image and tone reproduction. According to changing of packing quantity, we find an error between them as the result of comparison between theoretical value and experimental value in the expansion and contraction of image.

  • PDF

포장 및 적재 방법이 저온 저장 양파 품질 특성에 미치는 영향 (Effects on the Quality Characteristics of Onions by vArious Packing and Loading Types During Cold Storage)

  • 박세진;;김지영;김병삼
    • 한국포장학회지
    • /
    • 제30권2호
    • /
    • pp.141-147
    • /
    • 2024
  • 스마트 농산물산지유통센터(APC) 도입에 따라 인력 작업 체계를 기계화하고, 양파 수확 작업의 저비용 및 고효율화와 장기 저장을 위해 그물망 대신 톤백(TB)과 와이어메쉬파레트(WMP)로 포장하고 적재하여 저장하는 동안 양파의 수분함량, 경도, 색도, 가용성 고형분 함량, 관능 검사 등 저장성을 비교 분석하였다. 대조군과 비교했을 때 TB와 WMP를 사용한 경우 수분함량, 가용성 고형분 함량, 경도, 색도에서 유의적 차이가 관찰되지 않았다. 외관 변화에 있어 TB는 CON과 비교 시 큰 차이가 없음을 확인하였다. 이는 그물망을 대체하여 TB로 양파를 포장하고 적재 및 저장하는 것이 양파 수확 작업 시 저비용 및 고효율화하고 스마트APC의 공정 개선에 효율적으로 적용할 수 있을 것으로 검토되었다.

Effect of surface treatments on shear bond strength of resin composite bonded to CAD/CAM resin-ceramic hybrid materials

  • Gungor, Merve Bankoglu;Nemli, Secil Karakoca;Bal, Bilge Turhan;Unver, Senem;Dogan, Aylin
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.259-266
    • /
    • 2016
  • PURPOSE. The purpose of this study was to assess the effect of surface treatments on shear bond strength of resin composite bonded to thermocycled and non-thermocycled CAD/CAM resin-ceramic hybrid materials. MATERIALS AND METHODS. 120 specimens ($10{\times}10{\times}2mm$) from each material were divided into 12 groups according to different surface treatments in combination with thermal aging procedures. Surface treatment methods were airborne-particle abrasion (abraded with 50 micron alumina particles), dry grinding (grinded with $125{\mu}m$ grain size bur), and hydrofluoric acid (9%) and silane application. According to the thermocycling procedure, the groups were assigned as non-thermocycled, thermocycled after packing composites, and thermocycled before packing composites. The average surface roughness of the non-thermocycled specimens were measured after surface treatments. After packing composites and thermocycling procedures, shear bond strength (SBS) of the specimens were tested. The results of surface roughness were statistically analyzed by 2-way Analysis of Variance (ANOVA), and SBS results were statistically analyzed by 3-way ANOVA. RESULTS. Surface roughness of GC were significantly lower than that of LU and VE (P<.05). The highest surface roughness was observed for dry grinding group, followed by airborne particle abraded group (P<.05). Comparing the materials within the same surface treatment method revealed that untreated surfaces generally showed lower SBS values. The values of untreated LU specimens showed significantly different SBS values compared to those of other surface treatment groups (P<.05). CONCLUSION. SBS was affected by surface treatments. Thermocycling did not have any effect on the SBS of the materials except acid and silane applied GC specimens, which were subjected to thermocycling before packing of the composite resin.

Flip-Flop of Phospholipids in DMPC/POPC Mixed Vesicles

  • Kim, Min Ki;Kim, Chul
    • 대한화학회지
    • /
    • 제64권3호
    • /
    • pp.145-152
    • /
    • 2020
  • Flip-flop rate constants were measured by dithionite assay of NBD-PE fluorescence in DMPC/POPC vesicles made of various DMPC/POPC ratios. The activation energy, enthalpy, entropy, and free energy were determined based on the transition state theory. We found that the activation energy, enthalpy, and entropy increased as the amount of POPC increased, but the activation free energy was almost constant. These experimental results and other similar studies allow us to propose that the POPC molecules included in DMPC vesicles affect the flip-flop motion of NBD-PE in DMPC/POPC vesicles via increasing the packing order of the ground state of the bilayer of the vesicles. The increase in the packing order in the ground state seems to be a result of the effect of the overall molecular shape of POPC with a monounsaturated tail group, rather than the effect of the longer tail group.

Histomorphometric Study of Implants Initially Stabilized through Bone Graft Packing into the Osteotomy before Implant Placement in Case of Wide Defects

  • Lee, Wang-Jae;Hong, Ki-Seok
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: This study sought to evaluate the effects of bone graft wedging on the initial stability of implants in bone sites of unfavorable quality. Materials and Methods: Three male beagle dogs were used in this study. Osteotomies were performed with parallel drills (${\O}4.1{\times}10mm$), and fixtures (${\O}3.3{\times}8mm$) were placed. The control group was given implants without bone graft. Experiment group A was given implants with minimal initial stability using autobone grafts, whereas experiment group B was given xenografts. Groups were also divided by healing times at 4, 8, and 12 weeks. Results: All implants in the control group failed to osseointegrate. On the other hand, all implants in the experiment groups were clinically well-maintained during the entire experiment period. After 4, 8, and 12 weeks, bone-to-implant contact (BIC) ratio and implant stability quotient (ISQ) increased in the experiment groups. The differences between experiment groups A and B were not statistically significant, however. Conclusion: In unfavorable bone regions for dental implants, bone graft packing into the osteotomy prior to implant placement secured minimal initial stability and showed reasonable BIC ratios and ISQ values throughout the study period.