• Title/Summary/Keyword: Packing Group

Search Result 138, Processing Time 0.018 seconds

The Usefulness of Airway Tube Merocel® on Treatment of Nasal Bone Fracture (비골골절치료에서 기도 튜브 머로셀®의 유용성)

  • Jung, Yun Joo;Choi, Young Woong;Nam, Sang Hyun;Yoon, Gil Young
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.14-18
    • /
    • 2009
  • Purpose: Nasal packing materials are almost inserted at the end stage of closed reduction of nasal bone for postoperative bleeding control and stabilization of nasal bone. Conventionally, vaseline gauze was used for packing of nasal cavity. These days, Surgeons have tried to apply $Merocel^{(R)}$ into the nasal cavity more easily. It is difficult for patients to continue keeping the nasal packs for more than a week due to breathing difficulty. Moreover, nasal packing itself can also cause headache, dry mouth, stuffiness, etc. Methods: We performed a prospective study from March 1, 2008 to July 31, 2008. One hundred patients were divided into "$Merocel^{(R)}$ packing group" and "$Merocel^{(R)}$ and Airway Tube $Merocel^{(R)}$ packing group". Using two kinds of materials to each group after closed reduction, we observed and compared the amount of bleeding between two groups. We recorded patient's uncomfortable symptoms which were divided into four groups each 6, 24, 48 hours after nasal packing. Results: The result of the bleeding amount of Air Tube $Merocel^{(R)}$ group after 6 hours of nasal packing is that 3 people belong to mild group, 38 people moderate group, and 9 people severe group. After 6 hours of nasal packing, 11 patients have no complains. 16 patients were mild, 21 patients were moderate, 2 patients were severe. After 24 hours of nasal packing, no complain(18 patients), mild(24 patients), moderate(6 patients), severe(0 patient). After 48 hours of nasal packing, no complain(25 patients), mild(20 patients), moderate(5 patients), severe(0 patient). Conclusion: Regarding the amount of bleeding, there are no difference between two groups. In case of Air Tube $Merocel^{(R)}$ group, patient's discomfort is gradually improved after 24 hours of nasal packing, After 48 hours of nasal packing, most of the patients do not experience headache, dry mouth, stuffiness, etc. Therefore, Air Tube $Merocel^{(R)}$ can be useful for bleeding control. Moreover, it helps patients to breathe through nose more easily and reduce discomfort.

A comparison of the effects of epinephrine and xylometazoline in decreasing nasal bleeding during nasotracheal intubation

  • Song, Jaegyok
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.4
    • /
    • pp.281-287
    • /
    • 2017
  • Background: Various techniques have been introduced to decrease complications during nasotracheal intubation. A common practice is to use nasal packing with a cotton stick and 0.01% epinephrine jelly. However, this procedure can be painful to patients and can damage the nasal mucosa. Xylometazoline spray can induce effective vasoconstriction of the nasal mucosa without direct nasal trauma. In this study, we aimed to compare the efficacy of these two methods. Methods: Patients were randomly allocated into two groups (n = 40 each): xylometazoline spray group or epinephrine packing group. After the induction of general anesthesia, patients allocated to the xylometazoline spray group were treated with xylometazoline spray to induce nasal cavity mucosa vasoconstriction, and the epinephrine packing group was treated with nasal packing with two cotton sticks and 0.01% epinephrine jelly. The number of attempts to insert the endotracheal tube into the nasopharynx, the degree of difficulty during insertion, and bleeding during bronchoscopy were recorded. An anesthesiologist, blinded to the intubation method, estimated the severity of epistaxis 5 min after intubation and postoperative complications. Results: No significant intergroup difference was observed in navigability (P = 0.465). The xylometazoline spray group showed significantly less epistaxis during intubation (P = 0.02). However, no differences were observed in epistaxis 5 min after intubation or postoperative epistaxis (P = 0.201). No inter-group differences were observed in complications related to nasal intubation and nasal pain. Conclusion: Xylometazoline spray is a good alternative to nasal packing for nasal preparation before nasotracheal intubation.

The Effect of Nasal Packing with Rolled Silastic Sheet after Closed Reduction of Nasal Bone Fracture (비골 골절 교정 후 Rolled Silastic Sheet를 이용한 비강 충진의 효과)

  • Son, Kyung-Min;Yang, Jeong-Yeol;Kim, Gyu-Bo;Han, Yun-Ju;Cheon, Ji-Seon
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.602-608
    • /
    • 2011
  • Purpose: Nasal bone fracture is the most common type of facial bone fracture and most of nasal bone fracture is combined with septal fracture frequently. Nasal septum is important to support the distal nose and to maintain the nasal airway. But nasal septal fractures are usually unrecognized and untreated at the time of operation. Recently, various materials were using for nasal packing after closed reduction, however these materials are not focused on the correction of nasal bone and nasal septal fracture and many patients are suffered from nasal packing materials. Thus, the purpose of this study is to compare routine packing materials and rolled silastic sheet with respect to postoperative effect of correction of nasal bone fracture and discomfort of nasal packing materials. Methods: We examined 320 patients treated nasal bone fracture from January 2008 to December 2010. For Group I (n=92), $Merocel^{(R)}$ was used for nasal packing, for Group II (n=152) vaseline gauze was used, and Rolled silastic sheet (RSS) with vaseline gauze packing (VGP) was used for Group III (n=76). Under the general anesthesia, all patients were operated by closed reduction and nasal packing was done using three kinds of packing materials. At the time of postoperative 7 days, packing material was removed and studied for pt's satisfaction and postop. complications. Results: In patients with RSS with VGP, the complaints (nasal obstruction, foreign compressive sensation and discomfort during food ingestion) of keeping the nasal packing were decreased ($p$ <0.05) and the postoperative complication (deviation) were decreased comparing to vaseline gauze packing and $Merocel^{(R)}$ packing, however, these differences were not statistically significant ($p$ >0.05). Conclusion: Postoperative nasal packing with RSS with VGP was more comfortable to the patients and it was more effective method to correct the nasal bone fracture and nasal septal fracture.

Intelligent 3D packing using a grouping algorithm for automotive container engineering

  • Joung, Youn-Kyoung;Noh, Sang Do
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.2
    • /
    • pp.140-151
    • /
    • 2014
  • Storing, and the loading and unloading of materials at production sites in the manufacturing sector for mass production is a critical problem that affects various aspects: the layout of the factory, line-side space, logistics, workers' work paths and ease of work, automatic procurement of components, and transfer and supply. Traditionally, the nesting problem has been an issue to improve the efficiency of raw materials; further, research into mainly 2D optimization has progressed. Also, recently, research into the expanded usage of 3D models to implement packing optimization has been actively carried out. Nevertheless, packing algorithms using 3D models are not widely used in practice, due to the large decrease in efficiency, owing to the complexity and excessive computational time. In this paper, the problem of efficiently loading and unloading freeform 3D objects into a given container has been solved, by considering the 3D form, ease of loading and unloading, and packing density. For this reason, a Group Packing Approach for workers has been developed, by using analyzed truck packing work patterns and Group Technology, which is to enhance the efficiency of storage in the manufacturing sector. Also, an algorithm for 3D packing has been developed, and implemented in a commercial 3D CAD modeling system. The 3D packing method consists of a grouping algorithm, a sequencing algorithm, an orientating algorithm, and a loading algorithm. These algorithms concern the respective aspects: the packing order, orientation decisions of parts, collision checking among parts and processing, position decisions of parts, efficiency verification, and loading and unloading simulation. Storage optimization and examination of the ease of loading and unloading are possible, and various kinds of engineering analysis, such as work performance analysis, are facilitated through the intelligent 3D packing method developed in this paper, by using the results of the 3D model.

A study on calculation of friction coefficient and packing stress using static diagnosis test for a balanced globe valve in nuclear power plants

  • Kim, Jaehyung;Lim, Taemook;Ryu, Ho-Geun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2509-2522
    • /
    • 2021
  • A valve assembly used in nuclear power plants must be qualified and supervised. New technical standards such as ASME QME-1 2007 particularly require detailed qualification using experiment and analysis. Particularly, diagnostic tests and engineering studies are required for qualification of ASME QME-1 2007. Among these studies, the research on the measurement of friction coefficient and packing stress is important. The irregular change of packing stress along the stroke distance occurs because of the abnormal phenomenon, which must be found and studied with quantitative methods. Packing stress should be analyzed conservatively through experimentation and analysis. In this study, various formulas were applied to measure and calculate coefficient of friction and packing stress. This study can be used in relation to qualification and supervision of packing materials. And the calculation using static diagnosis test can be used to find the packing frictional force in dynamic diagnosis test with flow pressure in a pipe. This study has made it possible to reliably consider packing frictional force generated in a valve body. And so, it is believed that more margin can be secured when evaluating the capacity of valve actuator by applying the accurate frictional force generated in the valve assembly.

The Usefulness of Nasal Packing with Vaseline Gauze and Airway Silicone Splint after Closed Reduction of Nasal Bone Fracture

  • Kim, Hyo Young;Kim, Sin Rak;Park, Jin Hyung;Han, Yea Sik
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.612-617
    • /
    • 2012
  • Background Packing after closed reduction of a nasal bone fracture causes inconvenient nasal obstruction in patients. We packed the superior meatus with Vaseline gauze to support the nasal bone, and packed the middle nasal meatus with a Doyle Combo Splint consisting of an airway tube, a silastic sheet, and an expandable sponge to reduce the inconvenience. In addition, we aimed to objectively identify whether this method not only enables nasal respiration but also sufficiently supports the reduced nasal bone. Methods Nasal ventilation was measured via spirometry 1 day before surgery and compared to 1 day after surgery. To compare support of the reduced nasal bone by the 2 methods, 2 plastic surgeons assessed the displacementon X-rays taken after the surgery and after removing the packing. The extent of nasal obstruction, dry mouth, sleep disturbance, headache, and swallowing difficulty were compared with visual analog scales (VAS) on a pre-discharge survey. Results In the experimental group, the nasal respiration volume 1 day after surgery remained at $71.3%{\pm}6.84%$ on average compared to 1 day prior to surgery. Support of the reduced bone in the experimental group ($2.80{\pm}0.4$) was not significantly different from the control group ($2.88{\pm}0.33$). The VAS scores for all survey items were lower in the experimental group than in the control group, where a lower score indicated a lower level of inconvenience. Conclusions The nasal cavity packing described here maintained objective measures of nasal respiration and supported the reduced bone similar to conventional methods. Maintaining nasal respiration reduced the inconvenience to patients, which demonstrates that this packing method is useful.

Perioperative Orbital Volume Change in Blowout Fracture Correction through Endoscopic Transnasal Approach (안와파열골절의 비강내 내시경적 접근을 통한 교정에서 수술 전후 안와 용적 변화)

  • Lee, Jae Woo;Nam, Su Bong;Choi, Soo Jong;Kang, Cheol Uk;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.617-622
    • /
    • 2009
  • Purpose: Endoscopic transnasal correction of the blowout fractures has many advantages over other techniques. But after removal of packing material, there were some patients with recurrence of preoperative symptoms. Authors tried to make a quantitative anterograde analysis of orbital volume change over whole perioperative period which might be related with recurrence of preoperative symptoms. Methods: 10 patients with pure medial wall fracture(Group I) and 10 patients with medial wall fracture combined with fracture of orbital floor(Group II) were selected to evaluate the final orbital volume change, who took 3 CT scans, pre-, postoperative and 4 months after packing removal. By multiplying cross - section area of orbit in coronal view with section thickness, orbital volume were calculated. Then, mean orbital volume increment after trauma, mean orbital volume decrement after endoscopic correction and volume increment after packing removal were found out. And we tried to find correlations between type of fracture, initial correction rate and final correction rate. Results: The mean orbital volume increment of the fractured orbits were 7.23% in group I and 13.69% in group II. After endoscopic surgery, mean orbital volume decrement were 11.0% in group I and 12.46% in group II. Mean volume increment after packing removal showed 3.10% in group I and 6.50% in group II. The initial correction rate(%) showed linear correlation with final correction rate(%) after packing removal. And there were negative linear correlation between increment percentage of orbital volume by fracture and final correction rate(%). Conclusion: Orbital volume was proved to be increasing after removal of packing or foley catheter and it was dependent upon type of fracture. Overcorrection should be done to improve the final result of orbital blowout fracture especially when there are severe fracture is present.

Implementing Geometry Packing for MPEG Immersive Video (MPEG 몰입형 비디오를 위한 Geometry Packing 구현)

  • Jong-Beom, Jeong;Soonbin, Lee;Eun-Seok, Ryu
    • Journal of Broadcast Engineering
    • /
    • v.27 no.6
    • /
    • pp.861-871
    • /
    • 2022
  • The moving picture experts group (MPEG) developed the MPEG immersive video (MIV) standard for efficient compression of multiple immersive videos representing natural contents and computer graphics. The MIV compresses multiple immersive videos and generates multiple output videos which are defined as atlases. However, there is a synchronization issue of multiple decoders in a legacy device when decoding multiple encoded atlases. This paper proposes and implements the geometry packing method for adaptive control of decoder instances for low-end and high-end devices. The proposed method on the recent version of the MIV reference software worked correctly.

Comparison Study of the Use of Absorbable Materials as Internal Splints with Airway Silicone Splint and Absorbable Materials as Internal Splints Alone

  • Ji, So Young;Kim, Seung Soo;Park, Ki Sung;Baik, Bong Soo
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.4
    • /
    • pp.202-205
    • /
    • 2016
  • Background: Packing after closed reduction of nasal fracture causes uncomfortable nasal obstruction in patients. We packed the superior meatus with synthetic polyurethane foam (SPF) to support the nasal bone, and packed the middle nasal meatus with a nasal airway splint (NAS) and SPF. The aim of this article is prospectively to compare the subjective patient discomfort of SPF (Nasopore Forte plus) packing alone and SPF with NAS. Methods: We compared the prospectively subjective patient discomfort of SPF packing alone (group A) and SPF with NAS (group B) via visual analog scale (VAS; 0, no symptom; 100, most severe symptom). Results: At first postoperative day group B showed significant lower scores in dry mouth, sleep disturbance, conversation difficulty. However at third postoperative day, VAS scores of each group had no statistically significant differences. Moreover at fifth postoperative day group A had statistically significant lower scores for nasal pain, dry mouth than the group B. Conclusion: Combination method of using NAS and SPF have some advantage on the patient comfort from first postoperative day to third postoperative day.

A study on the effects of polymer core gate sizes on thickness shrinkage rate (폴리머코어 게이트 크기 변화가 두께 방향 수축률에 미치는 영향에 대한 연구)

  • Choi, Han-Sol;Jeong, Eui-Chul;Park, Jun-Soo;Kim, Mi-Ae;Chae, Bo-Hye;Kim, Sang-Yun;Kim, Yong-Dae;Yoon, Kyung-Hwan;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the variation of the shrinkage in the thickness direction of the molded parts according to the gate size of the polymer core fabricated through the 3D printer using the SLS method was studied. The polymer cores are laser sintered and the powder material is nylon base PA2200. The polymer cores have lower heat transfer rate and rigidity than the metal core due to the characteristics of the material. Therefore, the injection molding test conditions are set to minimize the deformation of the core during the injection process. The resin used in the injection molding test is a PP material. The packing condition was set to 80, 90 and 100% of the maximum injection pressure for each gate size. The runner diameter used was ∅3mm, and the gates were fabricated in semicircle shapes with cross sections 1, 2, and 3 ㎟, respectively. Thickness measurement was performed for 10 points at 2.5 mm intervals from the point 2.5 mm away from the gate, and the shrinkage to thickness was measured for each point. The shrinkage rate according to the gate size tends to decrease as the cross-sectional area decreases as the maximum injection pressure increases. The average thickness shrinkage rate was close to 0% when the packing pressure was 90% for the gate area of 1mm2. When the holding pressure was set to 100%, the shrinkage was found to decrease by 3% from the standard dimension due to the over-packing phenomenon. Therefore, the smaller the gate, the more closely the molded dimensions can be molded due to the high pressure generation. It was confirmed that precise packing process control is necessary because over-packing phenomenon may occur.