• Title/Summary/Keyword: Packed-bed

Search Result 355, Processing Time 0.031 seconds

Mathematical Simulation on Thermal Performance of Packed Bed Solar Energy Storage System (Packed Bed 태양에너지 저장시스템의 열성능에 관한 수학적 시뮬레이션)

  • KUMAR, ANIL;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.331-338
    • /
    • 2015
  • Solar air heaters (SAHs) are simple in design and widely used for solar energy collection devices, and a packed bed is one of typical solar energy storage systems of thermal energy captured by SAHs. This paper presents mathematical modeling and simulation on the thermal performance of various packed bed energy storage systems. A MATLAB program is used to estimate the thermal efficiency of packed bed SAH. Among the various packed bed energy storage systems considered, the wire mesh screen packed bed SAH shows the best thermal efficiency over the entire range of design conditions. The maximum of thermal efficiency of packed bed SAH with wire mesh screen matrices has been found to be 0.794 for Re=2000 - 20000 and ${\Delta}T/I=0.002-0.02$.

Removal of ammonia by packed bed bioreactor using immobilized nitrifiers (고정화 생물 반응기에 의한 암모니아 제거)

  • 김병진;이경범;서근학
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.177-182
    • /
    • 1999
  • Nitrifier consortium entrapped in Ca-alginate bead were packed into aerated packed bed bioreactor and non aerated packed bed bioreactor and the performances of two bioreactors were evaluated for the removal of ammonia nitrogen from synthetic aquaculture water. Total ammonia nitrogen(TAN) removal rate was decrease in aerated packed bed bioreactor below 0.3hr of hydraulic residence time(HRT), but increased in non aerated packed bed bioreactor until 0.5hr of HRT. At HRT of 0.05hr, TAN removal rate of non aerated packed bed bioreactor was about 335g TAN/㎥/day and the optimum ratio of packing height and inside diameter of reactor (H/D) was 4. The performance of two bioreactors indicated that non aerated packed bed bioreactor was better than aerated packed bed bioreactor in ammonia removal from synthetic aquaculture water.

  • PDF

Continuous Production of Agarooligosaccharides Using Packed-Bed Reactor (Packed-Bed 반응기를 이용한 한천올리고당의 연속생산)

  • 임동중;김종덕;강양순;공재열
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.398-402
    • /
    • 2001
  • Enzymatic hydrolysis of agar was carried out continuously to produce agarooligosaccharides by immobilized agarase in Packed-Bed Reactor. The reactor was constructed using a acryl tube with an internal diameter of 10 mm and a useful height of 140 mm. The Packed-Bed Reactor was 11 mL reactor volume as its length : diameter ratio was 14 : 1. The operation condition of reaction was performed with an 1 g/L agar concentration at 40$^{\circ}C$, 10 mM MOPS buffer(pH 7.0) and with the flow rate 3 mL∼48 mL/h at a dilution rate of 1.09∼5.45 h$\^$-1/. The hydrolysis products was identified DP6, DP4 and DP2 by HPLC. The conversion rate of agar was about 80% and amount of total agarooligosaccharide was 0.88 mg/mL at Packed-Bed Reactor.

  • PDF

Breakthrough modeling of furfural sorption behavior in a bagasse fly ash packed bed

  • Singh, Saurabh;Srivastava, Vimal Chandra;Goyal, Akash;Mall, Indra Deo
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.104-113
    • /
    • 2020
  • Adsorptive breakthrough modelling is essential for design of a sorption packed bed. In this work, breakthrough modelling of the furfural uptake in bagasse fly ash (BFA) packed bed has been performed. Effect of various parameters like bed height (Z = 15-60 cm), flow rate (Q = 0.02-0.04 L/min) and initial furfural concentration (Co = 50-200 mg/L) on the breakthrough curve of furfural sorption in a BFA packed bed have been studied. Enhanced breakthrough performance was observed for the higher value of Z, and lower values of Co and Q. For Co = 100 mg/L, packed bed operated at Q = 0.03 L/min and Z = 60 cm was found to have lowest adsorbent utilization rate of 5.61 g/L with highest breakthrough volume of 14.67 L. Bed depth service time and Thomas models well represented the experimental data points under all experimental conditions. It can be concluded that BFA can be utilized efficiently in continuous system for the removal of furfural. Overall, more than 99% of furfural was adsorbed in BFA packed bed at experimental conditions.

A Study on Heat Storage System Using Calcined Dolomite - Numerical Analysis of Heat Transfer in Calcined Dolomite Hydration Pocked Bed - (소성Dolomite 수화물계의 축열시스템에 관한 연구 - 소성Dolomite 수화반응층의 전열해석 -)

  • Park, Young-Hae;Kim, Jong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.9-21
    • /
    • 2002
  • To develope chemical heat pump using available energy sources, solar heat and other kinds of waste thermal energy, we have studied the heat transfer rate in cylindrical bed reactor packed with calcined Dolomite. Two dimensional (radial and circumferential) Partial differential equations, concerning heat and mass transfer in packed bed of calcined Dolomite, are solved numerically to describe the characteristics of the reaction of calcined Dolomite and heat transfer. The results obtained by numerical analysis about two dimensional profiles of temperature and conversion of reactant in the packed bed reactor and the amount of exothermic heat released from the reactor are follows. It was found that all of calcined Dolomite packed bed kept the reaction temperature of about 750K throughout the entire part of the bed, immediately after the steam was introduced exothermic reaction of hydration was proceeded from the packed bed inpu to output and from wall side to center. The rate of thermochemical reaction depends on the temperature and concentration and it is also governed by the boundary conditions and heat transfer rate in the particle packed bed.

Uncertainty in the Measurement of Radiative Energy Attenuation through Packed Spheres (구립자층내의 복사에너지 감쇠량계측의 불확정성에 관한 연구)

  • 김춘식;김경근;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 1991
  • Uncertainty is studied in the measurements of average packing density, thickness of packed spheres and transmittance in the experiments to study the effect of the bed height and the existence of the bed side walls on the transmittance of radiative energy through packed spheres. The packing density of the bed is obtained by counting the number of the spheres packed in three pipes with different heights. The bed height of the packed spheres is estimated from the number of spheres contained in the bed by using the relation between the bed height and the sphere number. The transmittance is obtained by dividing the intensity of the transmitted laser beam by the incoming-beam intensity. From the analysis, the uncertainity in the measurements of transmittance is shown to be less than 10.2%(95% coverage).

  • PDF

A Comparative Study on Treatment Efficiencies by Anaerobic Packed and Fluidized-bed Biofilm of Livestock Wastewater (축산폐수의 혐기성 충전층과 유동층 생물막법에 의한 처리효율의 비교연구)

  • 김은호;박현건;장성호
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.54-61
    • /
    • 1998
  • This study was conducted in order to evaluate the treatment efficiencies of anaerobic packed and fluidized-bed biofilm and to investigate applicability in treating livestock wastewater. Biocarbonate alkalinity(BA) and volatile fatty acid(VFA) were about 3,230-3,270 mg/l, 3,790-3,126 mg/l(as CaCO$_3$) and 224-402 mg/l, 141-387 mg/l(as CH$_3$COOH), and VFA/BA ratio was about 0.069~0.12, 0.045-0.12 in packed and fluidized-bed biofilm. When COD loading rate was 6.0 kg COD/$m^3\cdot$ day in packed and fluidized-bed biofilm, methane gas production were 3.23 l/day and 4.38 l/day, respectively. In the same COD loading rate, methane gas production volumes per kg COD removal were 0.25 m$^3$ CH$_4$/kg COD$_{rm}$ and $0.28 m^3 CH_4/kg COD^{rm}$, respectively. At this time, it could be estimated that fluidized-bed biofilm was more high. In case of HRT 0.94 day(6.0 kg COD/$m^3\cdot$ day) and 11 day(0.5 kg COD/$m^3\cdot$ day), packed-bed biofilm showed 59% and 81% COD removal efficiency, respectively. While fluidized-bed biofilm showed 72% and 85% removal efficiency, respectively. It was showed that fluidized-bed biofilm was more efficient. Packed-bed biofilm was higher than fluidized in treatment efficiencies of organic matters, but required continuous treatment using combined system, because it was very exceeded over an environmental standard solidified from '96 year. In operating fluidized-bed biofilm, if farm house consider high power cost according to high circulation ratio in an economic point of view, it would have an effect that farm house use packed-bed biofilm as combined system in treating livestock wastewater.

  • PDF

Pressure drop in packed beds with horizontally or vertically stratified structure

  • Li, Liangxing;Xie, Wei;Zhang, Zhengzheng;Zhang, Shuanglei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2491-2498
    • /
    • 2020
  • The paper concentrates on an experimental study of the pressure drop in double-layered packed beds formed by glass spheres, having the configuration of horizontal and vertical stratification. Both single-phase and two-phase flow tests are performed. The pressure drop during the test is recorded and the measured data are compared with those of homogeneous beds consisting of mono-size particles. The results show that for the horizontally stratified bed with fine particles atop coarse particles, the pressure drop in top layer is found higher than those of homogenous bed consisting of the same smaller size particles, while the measured pressure drop of bottom part is similar with those of similar homogenous bed. But for the homologous bed with upside-down structure, the stratification has little or no effect on the pressure drop of the horizontally stratified bed, and the pressure drop of each layer is almost same as that of homogeneous bed packed with corresponding spheres. Additionally, in vertically stratified bed, the pressure drops on the left and right side is almost equal and between those in homogeneous beds. It is speculated that vertically stratified structure may lead to lateral flow which redistributes the flow rate in different parts of packed bed.

An experimental study on the heat transfer characteristics in packed bed (충전층내에서의 열전달특성에 관한 실험적 연구)

  • 신현준;양한주;오수철
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.40-47
    • /
    • 1982
  • Heat transfer on packed bed is considered to be important for the effective designs of chemical reaction equipment, air conditioning system, and storage type heat exchanger, etc. Currently studies are being carried out quite actively in this field in order to increase the heat transfer efficiency. The effect of heat transfer is closely relater to materials, shapes, porosities and packing states of packed bed as well as mutual dimensional relations between particles and the container. Investigation shows that heat transfer results appear to be influenced by such parameters as fluid velocity through packed bed, mass flow, and thermal properties. It is noted that viscosity is also considered to be an important factor in this problem. In this study, effective thermal conductivities on packed bed, effects of thermal conductivity (Ke) and friction factor (Fk) according to change of porosity(.epsilon.) and Reynolds number(Reh(, and pressure loss of the fluid, are experimentally investigated. Results show that the effective thermal conductivity increases and the friction factor decreased, as against the increase of Reynolds number. But as the increase of porosity increase them both.

  • PDF

Extraction Conditions of Barley Tea in Cylindrical Packed Column (원통형 충전 탑에서 보리차의 추출조건)

  • 박상기;전재근
    • The Korean Journal of Food And Nutrition
    • /
    • v.4 no.2
    • /
    • pp.141-148
    • /
    • 1991
  • In order to Investigate the extraction mechanism of barley tea in cylindrical packed column, pilot plant scale packed column was designed and constructed. And extraction conditions for steady flow in the packed column were searched. The main results of this study are as follows ; 1. Circulation of the stock barley tea before the extraction running was indispensable In consideration of inequality, gas, particles existed in packed bed. Solid-liquid equilibrium was initially maintained after the circulation. 2. Flow direction of solvent must be up-flow for maintaining the constant bed height and flow rate during the extraction. Paessure drop in pucked bed was similar to decrease ratio of extract concentration. 3. The porosity of packed bed was in the range of 0.24∼0.36 according to the particle sloe. And it was decreased as the particle size became smaller.

  • PDF