• Title/Summary/Keyword: Package measurement

Search Result 276, Processing Time 0.025 seconds

Electrical Characterization of BGA interconnection for RF packaging (Radio Frequency 회로 모듈 BGA 패키지)

  • Kim, Dong-Young;Woo, Sang-Hyun;Choi, Soon-Shin;Jee, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.96-99
    • /
    • 2000
  • We presents a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and examined electrical parameters with a HP5475A TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3 $\times$ 3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, self inductance 146pH, mutual capacitance 10.9fF and mutual inductance 16.9pH. S parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55㎓ and the loss of 0.26dB. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF

Effect of Natural Antioxidant and Packaging Material on the Oxidative Stability of Waffle (천연 항산화제와 포장재질이 Waffle의 산화 안정성에 미치는 영향)

  • 신언환;한규홍
    • Culinary science and hospitality research
    • /
    • v.9 no.4
    • /
    • pp.1-12
    • /
    • 2003
  • This study was conducted to evaluating the antioxidative activities of waffle by natural antioxidants combination (tocopherol, rosemary extract and tea polyphenol) and packaging. Waffle stored at $25^{\circ}C$ and 35$^{\circ}C$ for 70 days were evaluated for acid value, peroxide value and Q$_{10}$ value. Tocopherol, either alone or with rosemary and tea polyphenol, was highly effective in inhibiting lipid oxidation of waffle at $25^{\circ}C$ and 35$^{\circ}C$. Especially among them, rosemary extract exhibited the best synergistic effect, as determined by peroxide value measurement. Waffle was then packaged under the following packing materials (OPP/DL/VMCPP, PET/DL/VMCCP). As the temperature condition, the modified atmosphere decrease in waffle package and increase peroxide value. This result indicated that the PET package was more effective in reducing oxidation than the OPP package.

  • PDF

Conjoint Measurement of Tourists' Preferences for Dolsan Leaf Mustard Kimchi(Brassica juncea) across Gender (남녀 관광객의 돌산 갓김치에 대한 선호도에 미치는 영향 요인의 컨조인트 평가)

  • Kang Jong-Heon;Jeong Hang-Jin
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.16 no.3
    • /
    • pp.242-250
    • /
    • 2006
  • The purpose of this study was to identify tourist product factor combinations which confer the highest utility to tourists and to establish the relative importance of factors in terms of their contribution to total utility across gender. Among 250 questionnaires, 230 questionnaires were utilized for the analysis. $X^2$ analysis, Conjoint model, Max. Utility model, BTL model, Logit model, K-means cluster analysis, and one-way anova analysis were used for this study. The findings from this study were as follows. First, the Pearson's R and Kendall's tau statistics showed that the model fitted the data well across gender. Second, it was found that total respondents and three clusters regarded taste price as the very important factor across gender. Third, it was found that the male and female tourists most preferred product with light red color, shaped package, and highly pungent taste sold at a cheap price in factory. Fourth, it was found that the male tourists most preferred simulation product with light red color, shaped package, and highly pungent taste sold at a cheap price in factory. The female tourists most preferred simulation product with light red color, shaped package, and mild taste sold at a cheap price in factory. Finally, the results of the study provide some insights into the types of effective product designs that can be successfully developed by marketers.

  • PDF

TELESCOPE CONTROL AND DATA ANALYSIS SOFTWARES FOR THE SOFT (태양 플레어 망원경의 제어 및 자료 분석 무른모)

  • Moon, Yong-Jae;Yoon, So-Yoon;Park, Young-Deuk;Jang, Be-Ho
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.47-62
    • /
    • 1997
  • In this paper we present a newly improved telescope control software and a newly developed data analysis software package for effective use of the Solar Flare Telescope(SOFT) The telescope control software permits us to make not only auto tacking of the SOFT, but also quantitative measurement of the solar irradiation, allowing us to provide weather monitorings. In addition we introduce an IDL widget software package for both monochromatioc (MONO version) and polarimetric data (VMG version) analysis. The MONO version is capable of loading FITS files, changing colors and contrast, image processing, displaying plots, and saving displayed plots by selected formats The VMG version, on the other hand provides a calibration of polarimetric data and plots of reduced vector magnetic fields.

  • PDF

A Study on the Inner Defect Inspection for Semiconductor Package by ESPI (ESPI를 이용한 반도체 패키지 내부결함 검사에 관한 연구)

  • Jung, Seung-Tack;Kim, Koung-Suk;Yang, Seung-Pil;Jung, Hyun-Chul;Lee, You-Hwang
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1442-1447
    • /
    • 2003
  • Computer is a very powerful machine which is widely using for data processing, DB construction, peripheral device control, image processing etc. Consequently, many researches and developments have progressed for high performance processing unit, and other devices. Especially, the core units such as semiconductor parts are rapidly growing so that high-integration, high-performance, microminiat turization is possible. The packaging in the semiconductor industry is very important technique to de determine the performance of the system that the semiconductor is used. In this paper, the inspection of the inner defects such as delamination, void, crack, etc. in the semiconductor packages is studied. ESPI which is a non-contact, non-destructive, and full-field inspection method is used for the inner defect inspection and its results are compared with that of C-Scan method.

  • PDF

Changes of Camber on Lamination Conditions in alumina/Tungsten Cofiring Multilayer Package (알루미나/텅스텐 동시소성에 의한 다층 팩키지 제조시 적층조건에 따른 camber의 변화)

  • 성재석;구기덕;윤종광;이상진;박정현
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.6
    • /
    • pp.601-610
    • /
    • 1997
  • In cofiring of multilayered alumina with tungsten, the change of camber with lamination condition was experimented and the effect of sintering shrinkage of alumina and tungsten was investigated. From the exact measurement of sintering shrinkage of tungsten thick film, as lamination pressure increased, the sintering shrinkage of alumina decreased but that of tungsten thick film was not changed. So it was though that the main factor which induced the sintering shrinkage difference between ceramics and metal with lamination condition was the change of sintering shrinkage of ceramics. In case of high lamination pressure, high green sheet density, the cofired specimen showed low camber due to low shrinkage difference between alumina and tungsten and there was a linear relation between camber and shrinkage difference. It was found that this shrinkage difference could change the thickness of tungsten film and the microstructure within via hole during cofiring.

  • PDF

Research on the Performance Test of System in Package Chips for the Digital Broadcasting Receiver (디지털 방송 수신용 System in Package 칩의 성능 검사에 관한 연구)

  • Kim, Jee-Gyun;Lee, Heon-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2228-2233
    • /
    • 2008
  • This research paper aims to establish a test process of the AFE SiP chip. It measured the sensitivity, current consumption and power consumption both on the evaluation socket board and Catalyst load board. As a result, the sensitivity became deteriorated with an average of 0.2[dBm] at the channel 62 only, the current consumption increased to an average of 0.57[mA] and the power consumption increased to an average of 1.76[mW], But all characteristics incomes the tolerance of the measurement, it also keeps almost the same level. Therefore this design of the test process improved a valid design.

Measurement of Deformations in Micro-Area Using High Resolution AFM Scanning Moiré Technique (고분해능 원자 현미경 스캐닝 무아레 기법을 이용한 미소 영역의 변형량 측정)

  • Park, Jin-Hyoung;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.6 s.261
    • /
    • pp.659-664
    • /
    • 2007
  • $Moire\'{e}$ interferometry is a useful technique to assess the reliability of electronic package because $Moire\'{e}$ interferometry can measure the whole-field and real-time deformations. The shear strain of a small crack site is important to the reliability assessment of electronic package. The optical limitation of $Moire\'{e}$ interferometry makes ambiguous the shear strain of a small area. An atomic force microscope (AFM) is used to measure the profile of a micro site. High resolution of AFM can apply to the $Moire\'{e}$ technique. AFM $Moire\'{e}$ technique is useful to measure the shear strain of a small area. In this research, the method to accurately measure the deformation of a small area by using AFM $Moire\'{e}$ is proposed. A phase-shifting method is applied to improve the resolution of AFM $Moire\'{e}$.

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF