• Title/Summary/Keyword: PWM Half bridge resonant inverter

Search Result 15, Processing Time 0.019 seconds

The Drive and Control Circuit Design of Cold Cathode Fluorescent Lamp for LCD Back Lighting (LCD 조광용 냉음극 형광램프의 구동 및 제어)

  • Kim Cherl-Jin;Hong Dae-Shik;Hwang Yo-Han;Yoon Shin-Yong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1211-1213
    • /
    • 2004
  • CCFL(cold cathode fluorescent lamp) are used to backlight of LCD(liquid crystal display). CCFL dimming methods are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, design of CCFL driving and control circuit by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. Inverter switching frequency is higher than resonant frequency for stable operating, and it is possible dimming control. On the basis of equivalent circuit, the validity of this study is confirmed by the comparison of simulation and experimental result.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

A Modeling and Driving Performance for CCFL Applied to the Display Unit (표시장치에 적용되는 CCFL의 모델과 인버터 구동)

  • Kim, Cherl-Jin;Yoo, Byeong-Kyu;Yoon, Shin-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.197-199
    • /
    • 2005
  • The Cold cathode fluorescent lamp (CCFL) are widely used to illuminate the liquid crystal display(LCD). Ballasts are required for CCFL because the lamp need high starting voltage and behave negative dynamic resistant characteristics in the desired region of operation. Dimming methods of CCFL are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, CCFL driving and control circuit is designed by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. The validity of this study is confirmed from the simulation and experimental results.

  • PDF

A Simulation Model of Cold Cathode fluorescent Lamp for High Frequency operation (고주파 구동 냉음극 형광방전램프의 시뮬레이션 모델)

  • Kim, Cherl-Jin;Yoo, Byeong-Kyu;Yoon, Shin-Yong;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1503-1505
    • /
    • 2005
  • The Cold cathode fluorescent lamp(CCFL) are widely used to illuminate the liquid crystal display(LCD). Ballasts are required for CCFL because the lamp need high starting voltage and behave negative dynamic resistant characteristics in the desired region of operation. Dimming methods of CCFL are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, CCFL driving and control circuit is designed by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. The validity of this study is confirmed from the simulation and experimental results.

  • PDF

A Study on the Effectiveness of Ultra-FRFET for the HV-BLU System in LCD TVs (LCD TV HV-BLU 시스템에 대한 Ultra-FRFET의 유효성에 관한 연구)

  • Lee, Sang-Taek;Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1394-1400
    • /
    • 2010
  • This paper introduces a newly improved Ultra-FRFET that has much better reverse recovery characteristic than that of the typical MOSFET and presents its effectiveness in the HV-BLU system of LCD TVs. The reverse recovery time, $T_{rr}$ of Ultra-FRFET is shorter than 40nsec and the peak value of reverse current, $i_{rr}$ is also much smaller compared to the typical MOSFET's, which are sufficient to prevent the MOSFET’s failures without additional FRDs and diodes in HV-BLU system with a half-bridge resonant inverter topology worked by PWM method. In order to verify the validity, the loss analysis and the implementation results in cases when both the conventional solution using typical MOSFETs with additional FRDs and a new solution using Ultra-FRFETs are applied to a HV-BLU of 40" LCD TV are presented. As a result, the effectiveness of Ultra-FRFET was verified and the results are presented in this paper.