• 제목/요약/키워드: PWM Capability

검색결과 86건 처리시간 0.022초

Design Considerations for Low Voltage Claw Pole Type Integrated Starter Generator (ISG) Systems

  • Lee, Geun-Ho;Choi, Geo-Seung;Choi, Woong-Chul
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.527-532
    • /
    • 2011
  • Due to the need for improved fuel consumption and the trend towards increasing the electrical content in automobiles, integrated starter generator (ISG) systems are being considered by the automotive industry. In this paper, in order to change the conventional generator of a vehicle, a belt driven integrated starter generator is considered. The overall ISG system, the design considerations for the claw pole type AC electric machine and a low voltage very high current power stage implementation are discussed. Test data on the low voltage claw pole type machine is presented, and a large current voltage source DC/AC inverter suitable for low voltage integrated starter generator operation is also presented. A metal based PCB (Printed Circuit Board) power unit to attach the 4-parallel MOS-FETs is used to achieve extremely high current capability. Furthermore, issues related to the torque assistance during vehicle acceleration and the generation/regeneration characteristics are discussed. A prototype with the capability of up to 1000 A and 27 V is designed and built to validate the kilo-amp inverter.

건설차량용 자동변속기의 변속제어기 개발연구 (A Research on Shifting Controller Development of a Automatic Transmission far Construction Vehicles)

  • 정규홍;이교일
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.234-242
    • /
    • 2002
  • In this research, a transmission control unit was developed for a wheel loader on the basis of 16-bit microcontroller system. The TCU has the basic functions which include shifting control algorithm, actuation of six proportional solenoid valves, signal conditioning for four speed sensors, remote data monitoring capability with RF-module and duty cycle identification system which could identify the duty cycles from PWM signals. In order to design the control system, the overall transmission structure of the wheel loader was investigated and its characteristics of shifting were analyzed in advance. For the purpose of identifying the existing control algorithm and acquire some information about the shifting performance, the shifting experiments were performed for various shifting conditions with the conventional TCU. From the previous work on the conventional TCU, the shifting scheme was designed with the open-loop control which is based on the experimental data only to verify the feasibility of the developing TCU's shilling capability. The experimental results show comparable shifting characteristics to that of conventional TCU though the tests were performed at restricted shilling conditions. Hence, we could have the confidence for the development of the wheel loader automatic transmission TCU and its shifting quality could be improved with the adoption of appropriate feedback control scheme.

4개 스위치를 갖는 Z-소스 동적 고조파 필터 (Z-Source Dynamic Harmonic Filter with Four Switches)

  • 수효동;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.254-255
    • /
    • 2013
  • In this paper, four switches three-phase Z-source dynamic harmonic filter is proposed. It has many advantages, such as reduction of the cost, switching loss and smaller drive circuit. In order to reduction harmonics, new PWM modulation technique with a variable index has been suggested that in comparison with a fixed index type has more capability. The paper presents an application of direct current control(DCC) method in Z-source dynamic harmonic filter to reduce the harmonics generated by the non-linear load. The experimental results will verify the validity of the proposed method.

  • PDF

클러치의 독립구동에 의한 자동변속기의 변속제어 (the Shifting Control in Automatic Transmission by Independent-Acting Clutches)

  • 김정관;한명철;홍금식
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.68-84
    • /
    • 2000
  • A study to reduce the transient torque in shifting in automatic transmission has been very important issue. Recently it is really dominant to decrease the torque by using independent-acting hydraulic circuit because we can control the clutch pressure actively and elaborately. So we design the new hydraulic circuit to control the clutches in automatic transmission and make the module library of computer simulations, We apply the results to GM model automatic transmission and carry out 1longrightarrow4 shifting simulations. By this work we recognize the capability of active and elaborate clutch pressure control using new hydraulic circuit. In addition We develop the tool to simulate the powertrain system. It is easier to update and exchange the subsystem model or parameters than conventional simulation tools.

  • PDF

디지털 제어 시스템의 연산시간 지연을 고려한 예측전류제어기에 관한 연구 (A Study on the Predictive Current Controller with the Compensation of Computation Time Delay in a Digital Control Systems)

  • 우명호;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2028-2032
    • /
    • 1997
  • When a high performance current control is desired, a computation time delay of a digital control system may deteriorate the control performance of a current controller. Such a non-negligible effect can be considerable in transient state. This paper deals with the modified predictive current control that compensates the time delay effects of a conventional predictive current control. The method is closely related to a local average current control and a symmetrical PWM pattern generation. Also some theoretical approaches are presented to describe the voltage saturation boundary of the power converter. For validation, the proposed method is applied to an active power filter system. The experimental results show considerable improvement in current tracking capability.

  • PDF

전동차용 고성능 AC구동시스템의 개발 (A High Performance AC Propulsion System for Electric Car)

  • 정기찬;방이석;김두식;서광덕;김남해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.278-280
    • /
    • 1996
  • This paper presents a high performance AC propulsion system for electric car to improve traction capability. The presented VVVF inverter was composed of as GTO thyristor and the the controller was fully digitalized by using 32bit DSP. The improved PWM algorithms and the new adhesion control were adapted to improve traction characteristics. This system could be possible the higher reliability and flexibility. The field test results showed the higher performances characteristics of the presented system.

  • PDF

확장된 칼만 필터를 이용한 속도 및 검출기가 없는 IPMSM의 최대토크 운전 (Maximum Torque Operation of IPMSM Drives without Speed & Rotor Position Sensors Using An Extended Kalman Filter)

  • 김윤호;윤병도;국윤상
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.21-25
    • /
    • 1996
  • To control the speed of IPMSM drives it is necessary to know the speed and the rotor position. This is normally done by measurement of this values with electromechenical sensors. In this paper, a new approach to the position elimination method for the high performance variable speed IPMSM drives with the current controlled PWM technique is presented. For the high performance drive capability in the speed region, a Extended Kalman filter algorithm is adopted to estimate the rotor position as well as the angular velocity for the practical sensorless IPMSM drives. The high performance drive characteristics of the proposed method are verified using the wide simulation.

  • PDF

유도가열기용 직.병렬 공진 고주파 인버터의 설계 (Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating application)

  • 홍순일;손의식
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.12-17
    • /
    • 2000
  • IN induction heating system the high frequency operation allows a rapid response to current fluctuation in the inverter and result in improved welding quality. To work induction heating of nonferrous metals, a welding power supply is need high working frequency and high power. This paper is shown design technique for increasing working frequency in induction heating for welding coppers. A series-parallel resonate inverter consists of H-type bridges, each of whose arms is composed of a combination of two parallel IGBTs. Inverter operating with the fixed frequency is controlled by pulse width modulation (PWM). As switching adapted the Zero-Voltage Switching technique to reduce switching losses the system is high efficiency. The propose inverter has feature which is high efficiency for very wide load variations with a narrow range of duty cycle ratio control and load short circuit capability. Detailed experimental results obtained from a 48[V] output, 500[W] experimental inverter are presented to verify the concept.

  • PDF

능동전력필터와 전력회수 능력이 있는 부하모의장치의 연계시험 분석 (Interconnection analysis of active power filter with electronic load simulator with Power-Recovery Capability)

  • 최준영;이두영;이동근;배병열;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.194-196
    • /
    • 2006
  • 본 논문에서는 새로 개발된 전력품질 보상 장치의 성능을 실험실에서 효과적으로 분석하기 위해 필요한 새로운 부하모의장치를 제안하였다. 제안하는 부하 모의장치는 2대의 PWM 인버터가 직류 단을 공유한 구조로 선형과 비 선형부하를 단일기기로 시험 가능하도록 설계되어 있다. 그리고 전력품질보상기의 하나인 능동전력필터와 연계시험을 수행하였다. 본 논문에서는 제안하는 부하모의장치와 능동전력필터의 연계 특성을 분석할 목적으로 PSCAD/EMTDC 소프트웨어를 이용하여 시뮬레이션 실시하였고 또한 실적용시 타당성을 검증할 목적으로 20kVA 용량의 부하모의장치와 10kVA용량의 능동전력필터를 제작하여 실험을 실시하였다. 시뮬레이션과 하드웨어 실험결과 제안하는 부하모의장치는 능동전력필터의 다양한 보상 능력 검증에 충분히 활용가능함을 알 수 있었다.

  • PDF

Performance Analysis of SSSC with Switching-level Simulation Model and Scaled Hardware Model

  • Han, Byung-Moon;Kim, Hee-Joong;Baek, Seung-Taek
    • Journal of Power Electronics
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 2001
  • This paper describes a switching-level simulation model and scaled hardware model for SSSC, which is useful for analyzing the dynamic interaction between the SSC and the power transmission system. A detailed simulation model with EMTP was developed to verity the SSSC operation with control system, and its increasing capability of power transmission through the line for a typical one-machine infinite-bus system. The simulation results of the developed model are compared with the experimental results froma scaled model fo 2KVA rating for evaluation the whole system operation.

  • PDF