복합적층판의 저속충격손상에 따른 PZT 센서와 PVDF 센서의 신호 분석 (Investigation on PVDE & PZT Sensor Signals for the Low-Velocity Impact Damage of Gr/Ep Composite Laminates)

  • 이홍영;김진원;최정민;김인걸
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.125-128
    • /
    • 2003
  • Low-velocity impact damage is a major concern in the design of structures made of composite materials, because impact damage is hidden inside and cannot be detected by visual inspection. The piezoelectric thin film sensor can be used to detect variations in structural and material properties for structural health monitoring. In this paper, the PVDF and PZT sensors were used for monitoring impact damage initiation in Gr/Ep composite panel to illustrate this potential benefit. A series of impact test at various impact energy by changing impact mass and height is performed on the instrumented drop weight impact tester. The wavelet transform(WT) is used to decompose the piezoelectric sensor signals in this study. Test results show that the particular waveform of sensor signals implying the damage initiation and development are detected above the damage initiation impact energy. And it is found that both PZT and PVDF sensors can be used to detect the impact damage.

  • PDF

압전필름센서를 이용한 복합재 평판의 저속충격 손상개시 모니터링 (Monitoring of Low-velocity Impact Damage Initiation of Gr/Ep Panel 7sing Piezoeleetric Thin Film Sensor)

  • 박찬익;김인걸;이영신
    • Composites Research
    • /
    • 제15권2호
    • /
    • pp.11-17
    • /
    • 2002
  • 우수한 동적 감지특서을 갖는 압전필름센서는 구조 건전성 모니터링이나 평가와 같은 구조물과 재료의 변화를 분석하는데 사용될 수 있다. 압전필름센서의 이러한 특성을 이용하여 Gr/Ep 복합재 평판의 충격 손상개시를 모니터링하였다. 압전필름센서와 스트레인게이지를 Gr/Ep 복합재 평판에 부착하여 다양한 조건의 에너지에 대한 충격시험을 낙하식 충격 시험기를 사용하여 수행하였다. 충격시험을 수행하는 동안 영구압입, 기지균열, 층간분리와 같은 충격 손상개시를 예측하기 위하여 센서신호를 분석하였다. 충격에너지를 초기 손상이 발생할 수 있는 크기 이상으로 증가시키면 손상의 개시와 진전에 대한 정보를 포함하는 특정 센서 신호를 관찰할 수 있었다. 특히, 압전필름세서는 스트레인게이지 보다 충격 손상개시 및 진전에 대한 좋은 감지 특성을 보여주었다.

압전필름센서 신호를 이용한 Gr/Ep 복합재 적층판의 고속충격 손상탐지 (High-Velocity Impact Damage Detection of Gr/Ep Composite Laminates Using Piezoelectric Thin Film Sensor Signals)

  • 김진원;김인걸
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.13-16
    • /
    • 2005
  • The mechanical properties of composite materials may degrade severely in the presence of damage. Especially, the high-velocity impact such as bird strike, a hailstorm, and a small piece of tire or stone during high taxing, can cause sever damage to the structures and sub-system in spite of a very small mass. However, it is not easy to detect the damage in composite plates using a single technique or any conventional methods. In this paper, the PYDF(polyvinylidene fluoride) film sensors and strain gages were used for monitoring impact damage initiation and propagation in composite laminates. The WT(wavelet transform) and STFT(short time Fourier transform) are used to decompose the sensor signals. A ultrasonic C-scan and a digital microscope are also used to examine the extent of the damage in each case. This research demonstrate how various sensing techniques, PVDF sensor in particular, can be used to characterize high-velocity impact damage in advanced composites.

  • PDF

8체질 맥법 검증을 위한 요골동맥 파형 측정 센서 개발

  • 문성수;정용원;이중재;공준웅;이흥세;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.9-12
    • /
    • 2001
  • In oriental medicine, it is possible to classify each person into eight kinds of constitutions based on the eight constitutional medicine theory. We developed a piezoelectric 3-channel tactile sensor using PVDF (polyvinylidene fluoride) film for pulse detection of the radial artery. High frequency buffer (impulse buffer), amplifier, 60 Hz noise notch filter and low pass filter were integrated on three sheets of PCB board. The pulses of the radial artery at three points were checked using our system. Each constitution of the eight ones has different combinations of pulses.

  • PDF

PVDF 필름 기반 센서를 이용한 정상인 및 폐쇄성 수면 무호흡증 환자에서의 무구속적인 렘 수면 모니터링 (Unconstrained REM Sleep Monitoring Using Polyvinylidene Fluoride Film-Based Sensor in the Normal and the Obstructive Sleep Apnea Patients)

  • 황수환;윤희남;정다운;서상원;이유진;정도언;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권3호
    • /
    • pp.55-61
    • /
    • 2014
  • In sleep monitoring system, polysomnography (PSG) is the gold-standard but previous studies revealed that attaching numerous amount of sensors disturb sleep during the test which is the fundamental disadvantage of PSG. We suggest an unconstrained rapid-eye-movement (REM) sleep monitoring method measured with polyvinylidene (PVDF) film-based sensor for the normal and the obstructive sleep apnea (OSA) patients. Nine normal subjects and seventeen OSA patients have participated in the study. During REM sleep, rate and variability of respiration are known to be greater than in other sleep stages. Based on this phenomena, respiratory signals of participants were unconstrainedly measured using the PVDF-based sensor with the PSG and REM sleep were extracted from the average rate and variability of respiration. In epoch-by-epoch REM sleep detection, proposed method classified REM sleep with an average sensitivity of 72.3%, specificity of 92.5%, accuracy of 88.9%, and kappa statistic of 0.60 compared to the results of PSG. Student's t-test showed no significant difference between the results of normal and OSA group. This method is potentially applicable to REM sleep detection in homing environment or ambulatory monitoring.

압전필름센서를 이용한 복합재 샌드위치 보의 저속충격 모니터링 (Low Velocity Impact Monitoring for a Composite Sandwich Beam Using Piezo Thin Film Sensors)

  • 박찬익;이관호;김인걸;이영신
    • 한국항공우주학회지
    • /
    • 제31권2호
    • /
    • pp.51-56
    • /
    • 2003
  • 압전필름센서는 우수한 동적 감지 특성을 갖고 있어 복합재 구조의 저속충격을 모니터링하는데 유용하게 사용될 수 있다. 복합재 샌드위치 보에 대한 충격응답함수를 유도하였으며, 이를 충격시험와 비교하였따. 충격시험은 손상이 발생하지 않는 저에너지 조건에서 계측장치가 부착된 낙하식 충격시험기를 이용하여 수행하였다. 충격하중에 으한 샌드위치보의 거동을 예측하는 정방향 문제와 압전필름센서 신호로부터 충격력을 복원하는 역방향 문제에서 시험과 해석의 결과는 잘 일치하였다. 본 연구를 통하여 압전필름센서를 이용한 복합재 샌드위치 구조의 저속충격 모니터링 가능성을 확인하였다.

PVDF 필름 기반 센서를 이용한 무구속적인 누운 자세 추정 (Unconstrained Estimation of Body Postures on Bed Using Polyvinylidene Fluoride Film-based Sensor)

  • 서상원;황수환;윤희남;정다운;최재원;이유진;정도언;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.169-176
    • /
    • 2014
  • As body postures on bed affects various sleep related diseases, it is considered as important information when monitoring sleeping in daily life. Though there have already been a few approaches to monitor body postures on bed conventionally, the development for simple and unconstrained methods is still needed to realize the long-term daily monitoring. Focusing on the fact that ballistocardiogram changes depending on the body postures on bed, we developed a novel method to estimate body posturesusing extremely simple, film-type ballistocardiogram sensor which is based on polyvinylidene fluoride(PVDF) film. With 10 subjects, we performed two experiments. One was for an estimation test to show that body postures on bed can be estimated by ballistocardiogram, and the other was for a reproducibility test to present the feasibility of ballistocardiogram based body postures monitoring. To estimate body postures on bed, we made an individual template set of body postures by designating one ballistocardiogram (BCG) sample as a template in each postures. Then, we calculated Pearson's correlation coefficients between a sample and each templates and estimated the body posture of the sample by choosing a posture which corresponds to the most significant correlation coefficients. As a result, we estimated body postures on bed with 99.2% accuracy in average and found that the estimation using ballistocardiogram is reproducible.

ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템 (The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal)

  • 김정도;김갑진;정기수;이정환;안진호;이상국
    • 정보처리학회논문지A
    • /
    • 제17A권3호
    • /
    • pp.145-152
    • /
    • 2010
  • 대부분의 모바일 웨어러블 헬스케어 모니터링 의류 시스템은 생체신호를 측정할 수 있는 센서와 데이터 취득과 무선 통신 및 제어를 담당하는 회로부, 이들을 내장하는 의복으로 구성된다. 기존의 의복형 헬스케어 시스템은 센서를 의복에 장시간 내장하기가 어렵고, 피부 접촉 시 시간에 따라 저항 값이 변화하기 때문에 장기적인 생체 신호 모니터링이 쉽지 않으며, 센서 전극과 회로 사이에 존재하는 신호선의 물리적 장애 요인도 가지고 있다. 본 연구에서는 이러한 문제점들을 해결하기 위하여, PVDF에 PEDOT 재료를 코팅하여 만든 패브릭 나노웹 ECG 전극과 PVDF 필름을 사용한 호흡 센서를 $10\;{\mu}m$ 두께의 디지털 실을 이용하여 사용자의 의류와 일체화하였다. 탈부착이 가능한 무선 블루투스(Bluetooth) 내장 스테이션과 디지털실로 기존 의류와 일체화한 생체 신호 측정용 의류 제작을 통해, 휴대폰에서 손쉽게 심전도(ECG)와 맥박신호를 표시 할 수 있었다.

Acoustic Performance Enhancement in PVDF Speakers by Using Buckled Nanospring Carbon Nanotubes

  • Ham, Sora;Lee, Yun Jae;Kim, Jung-Hyuk;Kim, Sung-Ryong;Choi, Won Kook
    • 센서학회지
    • /
    • 제28권6호
    • /
    • pp.360-365
    • /
    • 2019
  • A polyvinylidene fluoride (PVDF)-based film speaker is successfully fabricated with enhanced bass sound by incorporating buckled nanospring carbon nanotubes (NS-CNTs) as fillers. Various concentrations up to 1-7 wt% of uniformly dispersed buckled NS-CNTs are loaded to increase the beta (β)-phase fraction, crystallinity, and dielectric constant of the speaker, and this results in the bass part enhancement of about 19 dB full scale (dBFS) at 7 wt% filler loading of the piezoelectric film speaker.

진정 마취 시 호흡음 검출을 위한 PVDF 센서 및 시스템 개발 (Development of PVDF sensor and system to detect breathing sounds during deep sedation)

  • 이승환;리웅;임재중
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권1호
    • /
    • pp.153-159
    • /
    • 2019
  • 호흡은 환자의 상태를 판단하는 중요한 생체 신호 중 하나이다. 특히 진정 마취 시 환자의 무호흡 및 저호흡은 지속적인 모니터링 없이는 탐지하기가 어렵기 때문에 환자의 호흡 상태를 정확하고 간편하게 판단할 수 있는 지속적인 호흡 모니터링 방법이 필요하다. 현재 호흡 상태의 모니터링을 위한 다양한 장치들이 사용되고 있으나 임상 사용단계에서 응답 시간이 느릴 뿐 아니라 사용에 불편한 단점을 안고 있다. 본 연구에서는 이러한 문제점을 해결하고자 PVDF(polyvinylidene fluoride) 필름을 이용한 부착형 센서와 회로를 설계하고 제작하였으며, 진정 마취 시 호흡 신호를 감지하여 이상 호흡 징후를 조기에 발견할 수 있는 알고리즘을 포함하는 모니터링 시스템을 개발하였다. 본 연구의 결과는 진정 마취 시 뿐만 아니라 수면 관련 호흡 상태의 원격진료를 통한 다양한 의료산업 분야에 적용될 수 있을 것이다.