• 제목/요약/키워드: PVC-membranes

검색결과 52건 처리시간 0.031초

Silicone Rubber Blended with Polyurethane as the Matrix for Ion-Selective Membrane Electrodes

  • Lee, Hyun Jung;Rho, Kyung Lae;Kim, Chang Yong;Oh, Bong Kyun;Cha, Geun Sig;Nam, Hakhyun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.623-630
    • /
    • 1995
  • Silicone rubber-based sodium-selective membranes are developed for solid-state ion sensors. It was shown that the potetiometric performance of SR-based membranes are greatly dependent on the type of neutral carriers employed; among the three ionophores, N,N,N',N'-tetracyclohexyl-1,2-phenylenedioxydiacetamide (ETH 2120), bis[(12-crown-4)methyl]dodecylmethylmalonate (D12C4DMM) and monensin methyl ester (MME), examined, only ETH 2120 was compatible with the SR-based matrix. Addition of about 20 wt% plasticizer to the SR-based matrix provided the resulting membranes with potentiometric properties essentially equivalent to those of the corresponding PVC-based membranes. Owing to the strong adhesive strength of SR-based membranes, the CWEs coated \vith those membranes exhibited long lifetime with conventional electrode-like performance. Blending of PU into the SR matrix increased the lifetime of CWEs from two weeks to one month.

  • PDF

고분자용액의 물성이 수면전개 박막의 두께에 미치는 영향 (Effect of Physical Properties of Polymer Solution on the Thickness of Ultrathin Membrane Prepared by Water Casting Method)

  • 남석태;한명진;최호상;박영태
    • 공업화학
    • /
    • 제9권2호
    • /
    • pp.200-206
    • /
    • 1998
  • 수면전개법에 의해 제조된 박막의 두께에 대한 고분자용액의 표면장력과 점도의 영향을 검토하였다. 수면에서 고분자용액의 전개는 고분자용액의 표면장력과 점도에 의해 지배되며, 수면전개 박막의 두께도 이들 인자의 영향을 받는다. 고분자의 농도가 증가함에 따라 고분자용액의 표면장력과 점도는 증가하였으며, 표면장력의 크기는 PVC>PS>CA이었고, 점도의 크기는 CA>PS>PVC 였다. 고분자용액의 수면전개시 물과 고분자용액의 표면장력의 차는 전개구동력으로 작용하나 고분자용액의 표면장력과 점도는 전개저항으로 작용하였다. 수면전개 박막의 두께에 대한 고분자용액의 점도영향이 표면장력에 의한 영향 보다도 더 컸으며, 수면 전개 박막의 두께는 PS>CA>PVC 순으로 두꺼웠다.

  • PDF

전기화학 캐퍼시터용 PVC기반 가교 음이온교환 멤브레인의 제조 및 특성 (Preparation and Characterization of a Cross-Linked Anion-Exchange Membrane Based on PVC for Electrochemical Capacitor)

  • 김영지;김수연;최성호
    • 한국응용과학기술학회지
    • /
    • 제38권3호
    • /
    • pp.903-913
    • /
    • 2021
  • 본 연구에서는 싸이크론 헥산에서 PVC와 트리에틸디아민 (TEDA), 1,4-디메틸피페라진(DMP) 및 1,4-비스(이미다졸-1-일메틸)벤젠을 각각 치환반응시켜서3가지 형태의 PVC 멤브레인, AEM-1, AEM-2, and AEM-3를 제조하였다. AEM-1, AEM-2, and AEM-3멤브레인의 성공적인 제조 여부를 이온전도도(S/cm), 물함수율 (%), 접촉각, 이온교환능력 (meq/g), 열분석, SEM 및 XPS 분석 통하여 확인하였다. 또한, 제조된 가교 음이온 PVC멤브레인을 사용하여 유기전해질에서 전기화학 캐퍼시터 실험을 수행한 결과, 제조된 AEM-1, AEM-2 AEM-3 멤브레인의 경우 유기전해질에서 충/방전실험결과 매우 안정적임을 확인 할 수 있었다. 이러한 결과로 치환반응 후에 용매 캐시팅법으로 제조된 PVC기반 멤브레인 (AEM-1, AEM-2, 및 AEM-3)의 경우 유기전기화학캐퍼시터 (슈퍼캐퍼시터)용 분리막으로 사용될 수 있다.

Poly(vinyl chloride) 유도체로부터 제조된 바이오센서용 고분자막의 기체 투과특성 (Gas Permeation Properties of Polymeric Membranes for Biosensor Prepared from Poly(vinyl chloride) Derivatives)

  • 임춘원;김완영;이연식;윤정원;정용섭
    • 공업화학
    • /
    • 제10권3호
    • /
    • pp.362-366
    • /
    • 1999
  • Poly(vinyl chloride) (PYC) 유도제들로부터 용매증발법을 이용하여 바이오센서용 막을 제조하고 기체 투과특성을 조사하였다. 진공하에서 용매를 증발시켜서 제조된 막보다 공기 중에서 서서히 증발시켜 제조된 막의 투과도 계수가 더 높은 것으로 나타났다. PVC 유도체 막들에 대한 $CO_2$$O_2$의 투과도 계수는 공급부의 압력이 증가함에 따라 감소하였다. Carboxylated poly(vinyl chloride) (CPVC) 에 대한 dioctyl phthalate (DOP)의 첨가량이 증가함에 따라 투과도 계수는 증가하였다. 예를 들면 DOP 30 wt. %를 첨가하였을 때, $CO_2$$O_2$의 투과도 계수는 100 psig에서 각각 2.03, 0.96 Barrer 이었으며, DOP를 첨가하지 않았을 때 보다 약 4~5배 증가하였다. Poly(vinyl chloride-co-vinyl acetate) (PVCA)를 가수분해함으로써 OH기가 도입된 poly(vinyl chloride-co-vinyl acetate-co-vinyl alcohoI) (Syn-PVCAcAl)에 DOP를 첨가하였을 때 $CO_2$의 투과도 계수에서 시판제품 PVCAcAl보다 비교적 높은 값을 나타내었으나, $O_2$의 투과도 계수에는 차이가 없었다.

  • PDF

거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극 (Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles)

  • 정오진
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.211-220
    • /
    • 1996
  • 두 개의 황과 셀렌의 주개원자를 포함한 새로운 thia 및 diselena 크라운에데르 화합물을 합성하였다. 그리고 이 화합들을 중성운반체로 하고 PVC-가소제 (STPB)를 포함한 Hg(ll) 선택성 전극을 제작하였다. 이 전극들을 이용하여 여러 이온들의 전기화학적 선택성, 중성운반체의 종류 및 농도와 선택막의 매질에 대한 효과 그리고 실험용액의 pH변화에 대한 전극의 선택적 감응성들의 영향을 각각 검토하였다. 1,10-diselena-18-crown-6-PVC-STPB의 중성운반체의 막전극은 $10^{-2}$-10- M $Hg^{2+}$ 이온의 농도범위에서 ${28.2}\pm{0.6}$의 Nernstian 기울기를 갖는 좋은 선형적 감응성을 갖는다. 그리고 이 전극은 pH 2.5~6.0 범 위에서 알칼리토 금속, 몇가지 중금속 및 희토류 금속 이온에 대하여 좋은 선택성을 갖는다. 특히 이 전극은 수용액 중에서.$1^-$ 이온으로 Hg^{2-}$ 이온을 전위차 적정할 수 있는 센서로서 응용할 수 있다.

  • PDF

Electrochemical Sensor for the Selective Determination of Prindopril Based on Phosphotungestic Acid Plastic Membrane

  • Zareh, Mohsen M.;Wasel, Anower M.;Alkreem, Yasser M. Abd
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.3088-3092
    • /
    • 2013
  • A novel PVC membrane sensor for perindopril based on perindopril-phosphotungstate ion pair complex was prepared. The influence of membrane composition (i.e. percent of PVC, plasticizer, ion-pair complex, and kind of plasticizer), inner solution, pH of test solution and foreign cations on the electrode performance was investigated. The optimized membrane demonstrates Nernstian response ($30.9{\pm}1.0$ mV per decade) for perindopril cations over a wide linear range from $9.0{\times}10^{-7}$ to $1{\times}10^{-2}$ M at $25^{\circ}C$. The potentiometric response is independent of the pH in the range of 4.0-9.5. The proposed sensor has the advantages of easy preparation, fast response time. The selectivity coefficients indicate excellent selectivity for perindopril over many common cations (e.g., $Na^+$, $K^+$, $Mg^{2+}$, $Cu^{2+}$, $Ni^{2+}$, rhamnose, maltose, glycine and benzamide. The practical applications of this electrode was demonstrated by measuring the concentrations of perindopril in pure solutions and pharmaceutical preparations with satisfactory results.

수경재배 시 다량 이온 농도 측정을 위한 이온 선택성 전극의 응용 (Application of Ion-Selective Electrodes to Measure Ionic Concentrations of Macronutrients in Hydroponics)

  • 김민수;박두산;조성인
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.37-43
    • /
    • 2007
  • This study was carried out to investigate the applicability of PVC membrane-based ion-selective electrodes for macronutrients (K, Ca, and N) by measuring of potassium, calcium, nitrate ions in hydroponic nutrient solution. The capabilities of two ion-selective membranes with varying chemical compositions for each ion were evaluated in terms of sensitivity, selectivity, and lifetime to choose sensing elements suitable for measuring typical ranges of nutrient concentrations in hydroponic solutions. The selected calcium and nitrate ion-selective membranes showed effectively sensitive responses to calcium and nitrate ions with lifetimes of 25 and 15 days, respectively. The addition of a cation additive to the potassium membrane cocktail allowed its sensitivity to be increased whereas its lifetime was reduced from 30 days to 10 days.

수소이온 전도성 가지형 공중합체 전해질막 제조 및 분석 (Synthesis and Characterization of Proton Conducting Graft Copolymer Membranes)

  • 노동규;고종관;서진아;김종학
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.126.2-126.2
    • /
    • 2010
  • The "grafting from" technology to prepare the well-defined microphase-separated structure of polymer using atom transfer radical polymerization (ATRP) will be introduced in this presentation. Various amphiphilic comb copolymers were synthesized through this approach using poly (vinylidene fluoride) (PVDF), poly (vinylidene fluoride-co-chlorotrifluoroethylene) (P(VDF-co-CTFE) and poly(vinyl chloride) (PVC) as a macroinitiator. Hydrophilic side chains such as poly (styrene sulfonic acid) (PSSA) or poly (sulfopropyl methacrylate) (PSPMA) were grafted from the mains chains using direct initiation of the chlorine atoms. The structure of mass transport channels has been controlled and fixed by crosslinking the hydrophobic domains, which also provides the greater mechanical properties of membranes. Successful synthesis and microphase-separated structure of the polymer were confirmed by $^1H$ NMR, FT-IR spectroscopy and TEM. The grafted/crosslinked membranes exhibited good mechanical properties (400 MPa of Young's modulus) and high thermal stability (up to $300^{\circ}C$), as determined by a universal testing machine (UTM) and TGA, respectively.

  • PDF

Novel Silver(I) Ion Selective PVC Membrane Electrode Based on the Schiff Base (N2E,N2'E)-N2,N2'-Bis(Thiophen-2-ylmethylene)-1,1'-Binaphthyl-2,2'-Diamine

  • Jeong, Eunseon;Ahmed, Mohammad Shamsuddin;Jeong, Hae-Sang;Lee, Eun-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.800-804
    • /
    • 2011
  • A potentiometric sensor based on the Schiff base $(N^2E,N^{2'}E)-N^2,N^{2'}$-bis(thiophen-2-ylmethylene)-1,1'-binaphthl-2,2'-diamine has been synthesized and explored as an ionophore PVC-based membrane sensor selective for the silver ($Ag^+$) ion. Potentiometric investigations indicate a high affinity of this receptor for the silver ion. Seven membranes have been fabricated with different compositions, with the best performance shown by the membrane with an ionophore composition (w/w) of: 1.0 mg, PVC: 33.0 mg, DOA: 66.0 mg in 1.0 mL THF. The sensor worked well within a wide concentration range of $1.0{\times}10^{-2}$ to $1.0{\times}10^{-7}$ M, at pH 5, at room temperature (slope 57.4 mV/dec.), and with a rapid response time of 9 s; the sensor also showed good selectivity towards the silver ion over a huge number of interfering cations, with the highest selectivity coefficient for $Hg^{2+}$ at -3.7. Thus far, the best lower detection limit was $4.0{\times}10^{-8}$ M.

용매 고분자막 상에 고정된 나트륨 이온선택성 물질의 착물형성상수 결정 (Determination of Complex Formation Constant of Sodium-Selective Ionophores in Solvent Polymeric Membranes)

  • 강태영;김성배;오현준;한상현;차근식;남학현
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.466-473
    • /
    • 2000
  • 용매고분자막 상에 칼륨과 다양한 나트륨이온 선택성 중성 운반체의 착물형성상수(${\beta}_{MLn}$)를 고분자막형 광센서(optode)와 이온선택성 전극(ISE)을 이용하여 결정하였다. 수소이온선택성 발색물질(chromoionophore : ETH 5294)에 가장 널리 쓰이는 나트륨 이온선택성 물질들(4-tert-butylcalix[4]arenetetraacetic acid tetraethyl ester, ETH 2120, bis[(12-crown-4)methyl] dodecyl-methylmalonate 및 monensin methyl ester)을 첨가한 막과 첨가하지 않은 막으로 두 가지 다른 조성의 PVC 막을 제작하여, 일정 pH(0.05 M Tris-HCl, pH7.2)에서 알칼리금속 양이온(나트륨과 칼륨)의 농도 변화에 따른 광학적 감응을 측정하고, 또 일정한 알칼리금속 양이온 농도(0.1M)에서 pH변화에 따른 광학적 감응을 측정하였다. 또한 유사한 조성의 막을 각각 재래식 전극체에 장착하고 일정한 알칼리금속 양이온의 농도(0.1M)에서 pH 변화에 따른 전위치를 측정하였다. 양이온/수소이온의 활동도 비($a_{M^+}/a_{H^+}$)와 상대흡광도로 도시한 광센서 감응곡선과 수소이온농도에 따른 전위차 감응곡선으로부터 나트륨 이온선택성 리간드들의 착물형성상수를 결정하였다. 목적이온과 방해이온에 대한 착물형성상수들의 비로부터 얻어진 값은 실험적으로 얻어진 이온선택성 전극의 선택계수와 근접함을 확인하였다.

  • PDF