Study on PVC Mixed Silver Iodide Membrane Electrode (PVC 를 섞은 요오드화은 막전극에 관한 연구)

  • Kwon Young-Soon;Kim Jung-Hee;Park Kee-Chae
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.486-493
    • /
    • 1976
  • The PVC mixed silver iodide pellet was prepared by means of the Infrared Pellet presser and the pellet was used as an indicating membrane electrode, to measure the potentials for various silver ion activities, ranging from $10^{-1}$ to $10^{-6}$ M. The potential responses to silver ion activities were linear and the slope was much close to Nernstian relation as compared with that of the pure silver iodide pellet membrane electrode and the PVC coated silver iodide pellet membrane electrode. The mechanical property and chemical durability of this electrode were found much better than the others. This electrode did not show significant response to the other except silver ion, but had good response to halide ions, i.e., iodide, chloride, bromide and cyanide ions, in the concentration range $10^{-1}$ to $10^{-6}$ M. This electrode could be used as an indicating electrode in potentiometric titrations of single halide ion and also halide mixture with standard solution of silver nitrate.

  • PDF

${\beta}-Ag_3SI$ Single Crystal Membrane Electrode (${\beta}-Ag_3SI$ 단결정막 전극에 관한 연구)

  • Sin Doo-Soon;Seon-Cheon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.86-94
    • /
    • 1984
  • The single crystal ion-selective electrode,$ {\beta}-Ag_3SI/PVC-THF $membrane electrode has showed a linear potential response to the activities of iodide ion (10-1${\sim}$10-7M). The $ {\beta}-Ag_3SI$ membrane electrode was compared with AgI/PVC-THF membrane and copper metal plate membrane electrodes. In order to measure the selectivity coefficient of the electrodes toward $Cl^-$ and $Br^-$, the separation and mixed solution method were employed. The potential-time curve was obtained by the usual immersion technique and pH effect was also examined. The orders of selectivity for $Br^-$, $Cl^-$ and stability of response time are ${\beta}-Ag_3SI/PVC-THF $membrane > AgI/PVC-THF membrane > copper metal plate membrane. These electrodes could be used as indicating electrodes in the potentiometric titration of a single halide and mixed halides with the standard solution of silver nitrate.

  • PDF

A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver Ion

  • Shamsipur, Mojtaba;Kazemi, Sayed Yahya;Niknam, Khodabaksh;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2002
  • A new PVC-membrane electrode for $Ag^+$ ion based on a thia-substituted macrocyclic diamide has been prepared. The electrode exhibited a Nernstian response for $Ag^+$ over a wide concentration range $(1.7{\times}10^{-6}-1.0{\times}10^{-1}M)$. It has a response time <15 s and can be used for at least 3 months without divergence. The proposed membrane sensor revealed good selectivities for $Ag^+$ over a variety of metal ions and can be used in a pH range 3.0-7.5. It has been used successfully for direct determination of $Ag^+$ in different real samples and, as an indicator electrode, in the titration of silver ion.

Fabrication of Perchlorate Ion Selective PVC Membrane Electrode (과염소산 이온선택성 PVC막전극 제작)

  • 우인성;안형환;강안수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.298-305
    • /
    • 1998
  • The PVC membrane electrode for measuring perchlorate ion was developed by incorporating various quaternary ammonium sallts. The effect of chemical structure, the content of active material, the kind of plasticizers, and the membrane thickness on the electrode characteristic such as the linear response range and Nernstian slope of the electrode were studied. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of plasticizer(DBP). And the optimum membrane thickness was 0.45mm at this composition. Under the above condition, the linear response range was $10^{-1}~1.2\times10^{-6}$M, and the detection limit was $5.1\times10^{-7}$M with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below: $SCN^->I^-NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF

Lead-selective PVC Membrane Electordes Based on Bis(Crown ether)s

  • 오금철;강은철;정규성;팽기정
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.5
    • /
    • pp.556-558
    • /
    • 1999
  • Lead-selective PVC membrane electrodes based on newly synthesized bis(crown ether)s containing 18-crown-6 moiety was prepared using standard PVC membrane composition. In order to monitor lead in environmental samples by lead sensor, especially good selectivity over alkali and alkaline earth metals has to be obtained. Thus, responses of the PVC membrane prepared with new bis(crown ether)s and Fluka ionophore V (crown ether) base to various cations include lead, alkali and alkaline earth metal ions were investigated for their use as a lead sensor. The polymeric liquid membrane based on trans-1 8-crown-6 ether exhibits the best overall potentiometric performances as a lead-selective electrode in terms of a wide linear dynamic range (between 10-6 and 10-2 M, Pb2+), excellent detection limit (less than 10-6 M) and good durability within limited error. The preferences of lead over other cations, such as Ag+, Hg2+, Na+, Ca2+ and even K+ in the aforementioned electrode are much better than the Fluka ionophore V system.

The PVC Membrane Electrode for Measuring Hazardous Anion in Waste Water Process (폐수처리 공정중 유해음이온을 측정하기 위한 PVC 막 전극)

  • Woo, In-Sung;An, Hyung-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.47-59
    • /
    • 1995
  • The perchlorate, thiocyanate, and nitrate ion-selective PVC membrance electrode for measuring hazardous anion in waste water were developed by incorporating the quaternary ammonium salts as active material. Ion-selective characteristics in waste water were studied by the useful pH range, the selective coefficients to various interfering anions, and the stability of electrode potential. DBP was best as a plasticizer. The effect of the membrane thickness on the electrode characteristics was improved with decreasing the membrane thickness, but below the optimum membrane thickness the electrode exhibited an inverse trend. The electrode potential of perchlorate, thiocyanate, and nitrate electrode with TDDA, as active material, was stable within the pH range 4-11, 3-12, and 4-10 repectively. And the long-term potential stability of these electrodes were 3.0, 3.5, and 3.5 months respectively. The order of the selectivity coefficients was as shown below ; $ClO_4{^-}$ > $SCN^-$ > $I^-$ > $NO_3{^-}$ > $Br^-$ > $CN^-$ > $F^-$ > $Cl^-$ > $Ac^-$ > $H_2PO_4{^-}$, $SO_4{^-}$.

  • PDF

Treatment of Nitrogen Oxides in Ambient Air using a Ion-Selective Electrode (대기중 질산화물의 이온 선택성 전극에 의한 처리)

  • 안형환;우인성;강안수;이영순;김윤선
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.40-49
    • /
    • 1990
  • For the determination of polluant NOx in ambient air, nitrate ion-selective electrode(ISE) was made. To comparison of NOx in each method, the nitrate-ISE, NEBA, Orion electrode were used to determinee NOx in ambient air. In this work, the concentration of NOx in ambient air was average 0.06ppm. The results were good agreement with those obtained by each method within a relative error of 3%, Absorbing efficiency of nitrogen oxides in ambient air was good for Alkali solution. The determination of nitrogen oxides in ambient air using the Aliquat 336N-PVC membrane electrode was one of the useful method. The best characteristics of the Aliquat 336N-PVC me,mbrane electrode were obtained with the ion-exchanger concentration level of 6.5-9.1 percent by weight. The optimal membrane composition, was 9.09wt.% of ion-exchanger, 30.95wt.% of PVC, 60.6wt.% of plasticizer (DBP), and 0.5mm of thickness. Under the above condition, the electrode approached the Nernstian slope most closely, and the linear response ranges produced the best results.

  • PDF

A New Fe (III)-Selective Membrane Electrode Based on Fe (II) Phthalocyanine

  • Ozer, Tugba;Isildak, Ibrahim
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • A new miniaturized all solid-state contact Fe (III)-selective PVC membrane electrode based on Fe (II) phthalocyanine as a neutral carrier was described. The effects of the membrane composition and foreign ions on the electrode performance was investigated. The best performance was obtained with a membrane containing 32% poly (vinyl chloride), 64% dioctylsebacate, 3% Fe (II) phthalocyanine, and 1% potassium tetrakis (p-chlorophenyl) borate. The electrode showed near Nernstian response of $26.04{\pm}0.95mV/decade$ over the wide linear concentration range $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}M$, and a very low limit of detection $1.8{\pm}0.5{\times}10^{-7}M$. The potentiometric response of the developed electrode was independent at pH 3.5-5.7. The lifetime of the electrode was approximately 3 months and the response time was very short (< 7 s). It exhibited excellent selectivity towards Fe (III) over various cations. The miniaturized all solid-state contact Fe (III)-selective membrane electrode was successfully applied as an indicator electrode for the potentiometric titration of $1.0{\times}10^{-3}M$ Fe (III) ions with a $1.0{\times}10^{-2}M$ EDTA and the direct determination of Fe (III) ions in real water samples.

K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers (중성운반체를 이용한 K+ 이온선택성 PVC막 전극)

  • Kim, Yong-Ryul;Cho, Kyoung-Sub;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.734-741
    • /
    • 1998
  • Electrode characteristics were studied in the interface between sample solutions and $K^+$ ion selective PVC membrane electrodes containing neutral carriers, dibenzo-18-crown-6(D18Cr6) and valinomycin(Val). The effect of doping of base electrolytes, the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, and concentration variation of sample solution on the response characteristics of electrode such as the measured Nernstian slope, the detection limit, the linear response range, and potentiometric selectivity coefficients, were studied. In order to synthesize the membrane D18Cr6 and Val as neutral carriers were used, and complex between the carrier and $K^+$ ions were used as active materials. PVC membrane electrodes were made of plasticizers (DBP, DOS, and DBS), the base electrolyte[potassium tetraphenylborate(KTPB)], and solvent(THF). The chemical structure of carrier D18Cr6 was best for electrode and ideal electrode characteristics were appeared especially in case of doping of TPB. The optimum carrier content was about 3.23 wt % in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the electrode characteristics was improved. But its characteristics were lowered below the optimum membrane thickness because of the elution of carrier, deterioration of membrane strength, etc. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were in the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Perchlorate Ion-Selective PVC Membrane Electrode Based on the Quaternary Ammonium Salts (제4급 암모늄염을 이용한 과염소산 이온선택성 PVC막 전극)

  • 안형환;김용렬;강현춘;이한섭;이병철;강안수
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.126-135
    • /
    • 1993
  • Perchlorate ion-selective PVC membrane electrode responsive to $10^{-6}M$ was developed by incorporating the ion-pair complex of perchlorate with the quaternary ammonium salts as a active material. The effect of chemical structure, the content of active material, the kinds of plasticizers, and the membrane thickness on the electrode characteristics such as the linear response range and Nernstian slope of the electrode were studied. With the results, the useful pH range and the selectivity coefficients to various interfering anions were compared and investigated. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The electrode characteristics was improved with the decrease of the active material content below the optimum membrane composition, and DBP was the best as a plasticizer. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of ptasticizer(DBP). And the optimum membrane thickness was0.45mm at this composition. Under the above condition, thelinear response ranger was $10^{-1}~1.2 {\times} 10^{-6}M$, and the detection limit was $5.1{\times}10^{-7}M$ with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below : $SCN^->I^->NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF