• Title/Summary/Keyword: PV.1

Search Result 1,000, Processing Time 0.026 seconds

Transition of Isc according to Natural Solar Spectrum on c-Si and a-Si PV Module (결정질과 비정질 PV모듈의 자연광 스펙트럼에 따른 Isc의 변화)

  • Kong, Ji-Hyun;Ji, Yang-Geun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.86-91
    • /
    • 2009
  • In this paper, we analyze the Transition of Isc by natural solar spectrum of c-Si and a-Si PV module. Commonly, performance of photovoltaic (PV) module is estimated under the standard test condition (STC). That is, solar irradiance $1kW/m^2$, solar spectrum distribution: AM1 5G, module temperature $25^{\circ}C$ This means it rarely meets actual outdoor conditions. The solar spectrum always changes. So it is rare to fit the standard solar spectrum AM1 5G defined in ASTM G173-03 or IEC 60904-3. Thus spectral response of PV module is different depending on the material. so we estimated the variation of Isc at every minutes by comparing c-Si PV module with a-si PV module for outdoor conditions.

  • PDF

Determining the Warming Effect Induced by Photovoltaic Power Plants in neighboring Region Using an Analytical Model (해석학적 모델을 이용한 태양광 발전소 주변 지역의 기온 상승 추정 연구)

  • Kim, Hae-Dong;Huh, Kyong-Chun;Kim, Ji-Hye
    • Journal of Environmental Science International
    • /
    • v.27 no.3
    • /
    • pp.227-231
    • /
    • 2018
  • We studied the warming effect induced by Photovoltaic(PV) power plants in rural areas during summer daytime using a simple analytical urban meteorological model. This analysis was based on observed meteorological elements and the capacity of the PV power plant was 10 MWp. The major axis length of the PV power plant was assumed to be 1km. Data of the necessary meteorological elements were obtained from a special meteorological observation campaign established for a over a PV power plant. We assumed that the wind flowed along the major axis of the PV power plant(1 km). As a result, the air temperature on the downwind side of the PV power plant was estimated to invrease by about $0.47^{\circ}C$.

Software Development on Power and Economic Analysis of Photovoltaic System for Building Application (건물용 태양광발전 시스템 성능 및 경제성 평가 프로그램 개발 연구)

  • Yoon, Jong-Ho;Shin, U-Cheul;Park, Jae-Wan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The aim of this study is to develop the photovoltaic simulation program, called SimPV, which can Predict hourly based power generation of various PV modules and conduct an intensive economic analysis with Korean situation. To establish the reliability of the PV simulation results, we adopt the PV calculation algorithm of TRNSYS program of which verification has already well approved. Extensive database for hourly weather data of Korean 16 cities, engineering data for PV system and building load profiles are established. Case study on the 2.5kW roof integrated PV system and economic analysis are presented with the developed program.

Occurrence of a New Type of Pseudomonas syringae pv. actinidiae Strain of Bacterial Canker on Kiwifruit in Korea

  • Koh, Young Jin;Kim, Gyoung Hee;Koh, Hyun Seok;Lee, Young Sun;Kim, Seong-Cheol;Jung, Jae Sung
    • The Plant Pathology Journal
    • /
    • v.28 no.4
    • /
    • pp.423-427
    • /
    • 2012
  • Pseudomonas syringae pv. actinidiae strains, the causal agents of bacterial canker on kiwifruit, were isolated from Korea and Italy in 2011. Among 87 isolates, a total of six representative strains, three from Korea and three from Italy, were identified on the basis of biochemical and physiological tests. Identities were confirmed by PCR using P. syringae pv. actinidiae-specific primers PsaF1/R2, which amplified a 280-bp DNA fragment. The strains isolated from Korea in this study displayed BOX-PCR patterns similar to those isolated from Italy but different from those isolated previously in Korea or the pathotype P. syringae pv. actinidiae strain. The effector hopA1 and hopH1 genes, which are known to be present in strains isolated recently from France and Italy, were also present in P. syringae pv. actinidiae strains, SYS1, SYS2 and SYS4, isolated from Korea in this work. However, no amplicons of the expected size were obtained from strains previously isolated from Korea and Japan. In addition, the Korean strains isolated in this work belonged to haplotype I for the cts gene identical to those strains isolated from recent outbreaks in Italy. These results suggest that P. syringae pv. actinidiae strains isolated from Korea and examined in this work are a new type of strain similar to those found from recent outbreaks in Italy. This is the first report on the occurrence of cts haplotype I strains of P. syringae pv. actinidiae affecting kiwifruit plants in Korea.

A Study on the Priority Decision for Interconnection of PV System on Power Distribution System considering Customer Interruption Costs (정전비용 고려한 PV시스템의 배전계통 연계 우선순위 결정에 관한 연구)

  • Son, Chang-Nam;Han, Woon-Dong;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.163-168
    • /
    • 2014
  • In this paper, when photovoltaic systems are connected to distribution system, most effective capacity and location of PV system are studied considering customer interruption costs of power distribution system. The reliability model of PV system considering the duration of sunshine, the model of time-varying load and Roy Billinton test system (bus2 model) are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability and customer interruption costs for residential, general, industrial, and educational customer is evaluated.

Assessment on Power Quality of Grid-Connected PV System Based on Incremental Conductance MPPT Control (증분컨덕턴스 MPPT제어 기반 계통연계형 태양광발전시스템의 전력품질 평가)

  • Seol, Jae-Woong;Jang, Jae-Jung;Kim, Dong-Min;Lee, Seung-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.8-13
    • /
    • 2007
  • During the last years, there has been an increased interest in the new energy such as photovoltaic(PV) system from the viewpoint of environmental pollution. In this regard, this paper estimates the power quality of grid-connected PV system. As the maximum power operating point(MPOP) of photovoltaic(PV) power systems alters with changing atmospheric conditions, the efficiency of maximum power point tracking(MPPT) is important in PV power systems. Moreover, grid-connected PV system occurs some problems such as voltage inequality and harmonics. Therefore, this paper presents the results of a grid-connected PV system modeling that contains incremental conductance MPPT controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(TDD) and total demand distortion(TDD). For the case study, the measured data of the PV way in Cheongwadae, Seoul, Korea is used.

The Performance Evaluation Analysis of PV System for Arch and Flat-Plate Type (평판형 및 아치형 태양광발전 시스템의 성능평가 분석)

  • Piao, Zheng-Guo;Choi, Youn-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1012-1018
    • /
    • 2015
  • The studies on the operating performance analysis or design about the fixed tilt angle flat-plate photovoltaic (PV) system are still lively going off. However the operating property analysis about the arch type PV system which means PV array were designed as round type is dissatisfied. In this paper, we theoretically established the factors which are cause of the deterioration in performance of arch type PV system. In addition, we use the Solar Pro simulation tools to design both flat-plate type and arch type 30kW PV systems. The simulations about arch type PV system applied two ways such as central inverter and string inverter were conducted. The performance ratio (PR) of the PV system with flat-plate type shows the highest value 74[%] when the tilt angle is 30°. In case of arch type, when applying central inverter method, PR value shows approximately 73[%] and no more difference with arch type of the PV array. This value shows 1[%] decrease compare with the flat-plate type. However when applying string inverter methods, the average PR value shows 80 % and 6% improved than the central inverter method.

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

A Study on the Adolescent Growth Spurt of Skinfold, Muscle and Bone Variables Aligned on Peak Height Velocity in Boys and Girls (PHV 척도를 기준한 피하지방후, 근과 골 변인의 사춘기 발육분출에 관한 연구)

  • Shin Sang-Keun
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.339-344
    • /
    • 2006
  • The aim of this study was to examine the timing and magnitude of growth spurt in skinfold, body musle and bone related variables aligned on peak height velocity in boys and girls. In the study design, the subjects and the method were used by the cross-sectional investigation. The subjects participated in this study were 7 through 18 years of age belonged to typical primary, junior, senior high school students, and about 250 males and 250 females in each age group. The total subjects were 2,798 males and 2,762 females. All subjects of this study were lived in Pusan metropolitan city, Korea. The growth velocity magnitudes of sum of the four sites sknfold thickness, body musle and bone related variables. Velocity curve chart of physique was the smoothed according to an approximation of splines by the Sigma Plot-2001 graphic program. In this study, age at PHV of girls occurred eariler about 2 years than boys. In sum of four sites skinfold thickness, PV occurred -2 years from PHV in boys, and PV occurred +2 years from PHV in girls, respectively. In humerus breadth, two PV occurred before and after PHV in boys, whereas PV occurred -1 year from PHV in girls, respectively. In femur breadth, PFV and PHV appeared to occure the same time in boys, PV occurred -2 years from PHV in girls, respectively, In arm circumference, PV occurred after PHV in both sexes. In calf circumference, PV occurred +2 years from PHV in boys, PCCV and PHV appeared to occure the same time in girls, respectively. In magnitudes of peak velocity of body height, humerus breadth, femur breadth, arm circumference and calf circumfence, boys obtained higher than girls, on the other hand, girls obtained higher than boys in sum of four sites skinfold variable. we need to longitudinal and scientific investigation by Korean government level in adolescent growth spurt study, because childhood and adolescence achive higher positive physical education effect than the other ages.

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.