ESS Connected PV Monitoring System Supporting Redundant Communications (통신 이중화를 지원하는 ESS연계 태양광 모니터링 시스템)

  • Joo, Jong-Yul;Lee, Young-Jae;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제13권1호
    • /
    • pp.29-34
    • /
    • 2018
  • The systems associated with the ESS never stop. It runs 24 hours everyday. The system must be managed to run. The ESS system should perform normally even if the power IT equipment fails or communication failure occurs. Therefore, there is a need for a system that actively addresses, manages and controls the high precision power data of the ESS, even if a variety of failures occur. I would like to propose a power management communication unit to cope with the occurrence of communication failure. This paper also includes an integrated management system that can perform micro grid site management, maintenance and monitoring for the ESS system connected with the solar power generation facility.

REMOTE MONITORING OF WIND-PHOTOVOLTAIC HYBRID GENERATION SYSTEM USING MOBILE PHONE AND INTERNET (휴대폰과 인터넷을 이용한 풍력-태양광 복합발전 시스템의 원격 모니터링)

  • Xu, Zhenchao;Moon, Chae-Joo;Chang, Young-Hak;Lim, Jung-Min;Kim, Tae-Gon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, a remote monitoring system of wind-photovoltaic hybrid generation system using mobile phone and internet has been developed. Many kinds of data can be acquired, analyzed and saved automatically by this system. The hybrid system is composed of 1[kW] PV with DC/DC converter, battery banks and 5[kW] wind power system with power inductor and AC/DC converter. In addition, wind monitoring sensors, voltage and current meters, current transformers and potential transformers are used as accessory instruments. All of these signals are fed into DAQ (Data Acquisition) board after converting the data which have been processed by many types of converters, dividing circuits and signal conditioning circuits. These data can not only be displayed on a computer, transmitted using the server program to remote computer and saved on a computer as a file day by day but also be sent as a CDMA message. The monitored-data can be downloaded, analyzed and saved from server program in real-time via mobile phone or internet at a remote place. All of the programs were designed with LabVIEW software.

  • PDF

A Study on Generating efficiency of the Double Acting Stirling Engine/Generator (양방향 스털링엔진/발전기의 효율 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제27권1호
    • /
    • pp.114-120
    • /
    • 2016
  • This paper describes generating efficiency characteristics of the double acting Stirling engine/generator for domestic small-scale CHP (Combined Heat and Power) system. In small distributed generation applications, Stirling engine has competition from fuel cell, microturbine and etc. In order to be economical in the applications, a long life with minimum maintenance is generally required. Free piston Stirling engine (FPSE) has no crank and rotating parts to generate lateral forces and require lubrication. Double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric displacement and are connected with moving magnet type linear generators for power generation from PV work. In experiments, 1 kW class double acting free piston Stirling engine/generator is fabricated and tested. Heat is supplied to hot end of engine by the combustion of natural gas and converted to electric power by linear generators which are assembled with power pistons. The electric parameters such as voltage, current and phase are measured with for variable flow rate of fuel gas. Especially, generating efficiency of FPSE is measured with three different measurement methods. Generating efficiency of the double acting Stirling engine/alternator is about 24%.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

A Study on Effects of Partial Shading on PV System applied to the Offshore Plant

  • Lee, Ji Young;Yang, Hyang Kweon;Oh, Jin Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.152-158
    • /
    • 2015
  • Unlike photovoltaic systems installed on land, photovoltaic systems applied to the offshore plant have the characteristic that is installed in a limited space. For single point mooring plant, it is advantageous in terms of a reliable power supply to be installed in different directions of photovoltaic panels, because it is not possible to identify the position of the sun by rotation of the plant itself. Differences of installation angle between photovoltaic panels make a difference of the intensity of radiation irradiated on each photovoltaic panel, and it brings loss of generation quantity due to the partial shading. In order to provide a photovoltaic system suitable for offshore plant, the modeling which contains multiple photovoltaic panels controlled by single controller is performed. Then, it was examined how the output characteristics of the photovoltaic system change about the difference of the intensity of radiation that varies depending on the altitude of the sun. Finally, through the simulation, a development model of the photovoltaic system which is suitable for offshore plant is suggested.

A Study on Module-based Power Compensation Technology for Minimizing Solar Power Loss due to Shaded Area (음영지역 발생으로 인한 태양광 발전손실 최소화를 위한 모듈부착형 전력보상기술에 관한 연구)

  • Kim, Young-Baig;Song, Beob-Seong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제13권3호
    • /
    • pp.539-546
    • /
    • 2018
  • Recently, as the solar power generation market is rapidly increasing, interest is focused on research for minimizing the output of the solar cell module. The role of the power optimizer is important when inconsistencies occur in photovoltaic power generation. In the conventional system, centralized inverter method and microinverter method are mainly used. In this paper, we analyze the problem of power generation efficiency loss due to the incompatibility of existing system configuration methods. We also proposed a module - type power compensation method that can improve the mismatch caused by shading. The proposed module - based power optimizer is implemented and compared with the existing operation method. From the simulation result, it was confirmed that the efficiency of the proposed operation method is improved compared to the existing method.

A Study on Effect of Connecting the PV Power generation to the Distribution System (태양광발전의 배전계통 도입 영향 고찰)

  • Ahn, Kyo-Sang;Jung, Nak-Hun;Kim, Kyeung-Hwan;Hwang, Woo-Hyun;Kim, Eui-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1062_1063
    • /
    • 2009
  • 청정에너지로 각광받고 있는 태양광발전은 지구환경문제가 작금의 관심사로 떠오르면서 더욱더 보급이 확산되고 있다. 정부에서도 태양광발전 사업자의 지원정책과 일반보급사업, 지방보급사업 및 100만호 보급사업 등의 강력한 정책적 지원으로 보급의 활성화를 위한 기반을 마련하게 되었다. 미래의 지구환경과 청정에너지에 대한 국민들의 관심 고조 등은 정부정책과 맞물려 전력계통에 대규모 대용량의 발전시스템과 다수의 시스템이 도입되면서 전력계통 운영에 작은 변화를 보여 주고 있다. 본 고에서는 태양광발전의 계통도입에 대한 검토사항과 확대 도입에 의한 영향에 대하여 고찰하고자 한다.

  • PDF

A Study on Characteristics of Charging and Discharging for Lead Storage Batteries in Series (직렬 연결된 납축전지의 충방전 전압 특성 연구)

  • Moon, Chae-Joo;Jin, Jong-Soo;Seo, Dong-Choon;Jung, Kwen-Sung;Kim, Tae-Gon;Kim, Young-Gu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.75-79
    • /
    • 2008
  • To control the lead storage batteries it is necessary to consider the characteristics of each battery connected in series. In this study, the charging and discharging characteristics of sealed lead storage batteries 12V/1.2A was investigated one by one through experiments. The results of the experiment shows that one should consider the state of each battery to prevent overcharge or deep discharge. Also, we designed an equipment to measure battery voltages simultaneously using micro-controller. This equipment will be useful for monitoring batteries at PV generation system.

  • PDF

Design of Photovoltaic Generation System Using PLECS (PLECS를 이용한 태양광 발전시스템 설계)

  • Choe, Gyu-Yeong;Kim, Jong-Soo;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1093-1094
    • /
    • 2008
  • 본 논문은 수학적 모델링이 간편하고 제어기법의 적용이 쉬운 MATLAB 기반으로 태양광 셀과 모듈을 모델링하고 기존의 P&O MPPT제어 알고리즘을 분석하고 구현하였으며 전력전자 회로의 구현이 간단한 PLCES를 사용하여 부스트 컨버터 구현하였다. 이로써 일사량 변화와 온도변화의 영향이 고려되고, MATLAB 기반이므로 시뮬레이션 시간이 단축되며, 다양한 제어기법을 쉽게 적용할 수 있는 PV 발전시스템을 구축하였으며 시뮬레이션을 통해 태양광 모델의 성능과 MPPT 제어 성능을 검증하였다

  • PDF

A Study on Characteristics of PV Generation System in the Southwest Seaside Island (서남해안 도서지역 태양광 발전소의 발전 특성)

  • Moon, Chae-Joo;Jin, Ou-Sam;Jung, Sang-Weon;Kwak, Wang-Shin;Song, Sung-Geun;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1116-1117
    • /
    • 2008
  • 본 연구는 서남 해안의 섬 지역에 설치된 태양광 발전소의 발전 특성을 측정하고 분석한 것이다. 발전소의 총 발전 용량은 806.4kWp 이고 고정식과 추적식이 복합적으로 시설되어 있다. 일사량을 측정하고 인버터의 효율을 분석하였으며 전력 계통을 분석하였다. 인버터의 측정 및 분석결과 인버터는 효율이 평균 94.5%였고, 전력 계통의 분석은 파형 분석과 상 불평형 분석, 고조파 분석을 실시하였다. 주파수 분석결과 전압은 THD가 2%, 전류는 1.5%로 양호하게 나타남을 확인하였다.

  • PDF