• Title/Summary/Keyword: PV generation system

Search Result 512, Processing Time 0.027 seconds

Simple Technique Reducing Leakage Current for H-Bridge Converter in Transformerless Photovoltaic Generation

  • Kot, Radoslaw;Stynski, Sebastian;Stepien, Krzysztof;Zaleski, Jaroslaw;Malinowski, Mariusz
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.153-162
    • /
    • 2016
  • Given their structural arrangement, photovoltaic (PV) modules exhibit parasitic capacitance, which creates a path for high-frequency current during zero-state switching of the converter in transformerless systems. This current has to be limited to ensure safety and electromagnetic compatibility. Many solutions that can minimize or completely avoid this phenomenon, are available. However, most of these solutions are patented because they rely on specific and often complex converter topologies. This study aims to solve this problem by introducing a solution based on a classic converter topology with an appropriate modulation technique and passive filtering. A 5.5 kW single-phase residential PV system that consists of DC-DC boost stage and DC-AC H-bridge converter is considered. Control schemes for both converter stages are presented. An overview of existing modulation techniques for H-bridge converter is provided, and a modification of hybrid modulation is proposed. A system prototype is built for the experimental verification. As shown in the study, with simple filtering and proper selection of switching states, achieving low leakage current level is possible while maintaining high converter efficiency and required energy quality.

Genomic Analysis of the Carrot Bacterial Blight Pathogen Xanthomonas hortorum pv. carotae in Korea

  • Mi-Hyun Lee;Sung-Jun Hong;Dong Suk Park;Hyeonheui Ham;Hyun Gi Kong
    • The Plant Pathology Journal
    • /
    • v.39 no.4
    • /
    • pp.409-416
    • /
    • 2023
  • Bacterial leaf blight of carrots caused by Xanthomonas hortorum pv. carotae (Xhc) is an important worldwide seed-borne disease. In 2012 and 2013, symptoms similar to bacterial leaf blight were found in carrot farms in Jeju Island, Korea. The phenotypic characteristics of the Korean isolation strains were similar to the type strain of Xhc. Pathogenicity showed symptoms on the 14th day after inoculation on carrot plants. Identification by genetic method was multi-position sequencing of the isolated strain JJ2001 was performed using four genes (danK, gyrB, fyuA, and rpoD). The isolated strain was confirmed to be most similar to Xhc M081. Furthermore, in order to analyze the genetic characteristics of the isolated strain, whole genome analysis was performed through the next-generation sequencing method. The draft genome size of JJ2001 is 5,443,372 bp, which contains 63.57% of G + C and has 4,547 open reading frames. Specifically, the classification of pathovar can be confirmed to be similar to that of the host lineage. Plant pathogenic factors and determinants of the majority of the secretion system are conserved in strain JJ2001. This genetic information enables detailed comparative analysis in the pathovar stage of pathogenic bacteria. Furthermore, these findings provide basic data for the distribution and diagnosis of Xanthomonas hortorum pv. carotae, a major plant pathogen that infects carrots in Korea.

Implementation of a Photovoltaic System Simulator for Interconnecting with Bipolar ±750V DC distribution Grid (바이폴 ±750 직류 배전망 연계용 태양광 발전 시뮬레이터 구현)

  • Kim, Tae-Hoon;Kim, Seok-Woong;Cho, Jin-Tae;Kim, Ju-Yong;Jung, Jae-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1800-1805
    • /
    • 2016
  • The micro-grid designed as bipolar ${\pm}750V$ low-voltage DC power distribution system demonstrated by KEPRI, demands interconnection of a number of small decentralized power source including variable renewable generator. Therefore, variable researches for the influence of interconnection with the bipolar typed DC grid and these variable power sources are required for superior quality of power distribution. Renewable power generation simulators for the bipolar ${\pm}750V$ low-voltage DC power distribution system are necessary for such researches. In this paper, we carry out a research on the photovoltaic simulator that be actually able to interconnect with a bipolar ${\pm}750V$ low-voltage micro-grid. Simulator for this research is not only able to simulate photovoltaic generation according to weather informations and PV modules characteristics, but also contribute to stabilization of bipolar ${\pm}750V$ low-voltage of the system. Therefore, the simulator was designed to develop a system that can situationally respond to variable control algorithms such as the MPPT control, droop control, EMS power control, etc.

A study on theload dispersion a new PV tracking system (하중 분산형 새로운 태양광 추적 장치에 관한 연구)

  • Seo, J.J.;Song, S.K.;Park, S.J.;Lee, S.H.;Moon, C.J.;Kim, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1702-1704
    • /
    • 2005
  • In solar power system, the height and azimuth of the sun are important parameters which control generated power magnitude. The way that controls the daily generation magnitude according to latitude and longitude and uses two axles is often used in the existing sunlight racing system now. In this two-axle sunlight track control system the self-load is concentrated on one FRAME. It is influenced of the regular load, snow load and the wind load, etc. It is difficult to set up the system in the building already built up. This research is a development about the small-scale economy track device of independent load-dispersing type solar generation system. The position track algorithm is through calculating the trail of height and azimuthal of the sun calculation to follow the sun.

  • PDF

The Study on Algorithm for Partial shade Compasation of PV (태양광 발전시스템의 부분그늘 보상을 위한 알고리즘에 관한 연구)

  • Koh K. H.;Lee H. W.;Suh K. Y.;Koh H. S.;Moon S. C.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.271-274
    • /
    • 2003
  • In this paper, compare and analyze existent MPPT algorithms. Existent algorithms have defects which don't generate it in a partial shade or low insolation. Therefore, to supplement it, we design improved IncCond algorithm consisted of a Aux. switch and capacitor with Generation Control circuit which can always obtain maximum generation power at the factor which is reduced generational efficiency by partial shade. Generation Control circuit is method which can always get maximum output power as it regularly controls each voltage of serial connected solar cell. Accordingly, it can improve efficiency and confidence of utility interaction inverter. Construction of system use a low price PIC16F87X. We analyze special character according to system operation through simulation and prove the validity through experiments.

  • PDF

Algorithm Deciding Offshore Cable Layout Valid for Integrated Power Supply Between Adjacent Islands (근거리 도서간 통합전력공급에 유효한 해저케이블 포설 방안 결정 알고리즘)

  • Kim, Mi-Young;Rho, Dae-Seok;Moon, Guk-Hyun;Seo, In-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.28-36
    • /
    • 2018
  • Islands are supplied with power from diesel generation or from photovoltaic power generation, and problems with offshore environmental impacts (age deterioration, salt pollution), environmental pollution (exhaust gas, noise, dust) and power generation costs (installation, maintenance) have increasingly emerged. In 2016, the cost recovery rate was only 27%, and deficits reached 73% on 65 islands managed by KEPCO. In terms of deficits, the costs incurred in the power generation sector accounted for 91%, with the ratio of fixed costs at about 60%. Analysis suggests that operating costs can be reduced with an optimal power supply system that improves power generation efficiency and makes operating systems more efficient. Therefore, it is possible to simplify fuel transportation and facility maintenance, because one island integrates the power plants of remote islands, and offshore cable is used to supply power to the other islands. From the economic evaluations in this paper, an algorithm deciding offshore cable layout validity for an integrated power supply between adjacent islands is presented. Simulation results based on the proposed algorithm confirmed that an integrated power supply is economical for existing stand-alone operations on islands having diesel generation, low peak power, and near distances.

Economic Evaluation of Unused Space PV System Using the RETScreen Model - A Case Study of Busan, Gangseo-gu - (RETScreen 기반 유휴공간 태양광 발전 시스템의 경제성 평가 연구 - 부산시 강서구 사례를 중심으로 -)

  • Kang, Seongmin;Jeon, Youngjae;Cho, Sung Heum;Lee, Daekyeom;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, There has been much discussed about unused space. This space can be used in a variety of ways. Utilizing it as a facility, craft shop, and utilizing renewable energy generation facilities. Especially, in terms of climate change should be supplied renewable energy. Renewable energy needs to be developed in terms of responding to climate change, and the recent Paris agreement is also emphasizing the importance of renewable energy. In particular, renewable energy needs to be widely disseminated. And renewable energy is limited space. In this regard, idle land can provide opportunities for securing new renewable energy generation facilities. The introduction of new and renewable energy facilities in idle space can enhance the self-sufficiency rate of the local community, which is significant in terms of responding to climate. In this study, to investigate the possibility of utilizing a unused space for a photovoltaic power generation facility, we investigated the amount of electricity which could be generated through photovoltaic power generation, and the economic effects, using a RETScreen model. The results showed that 9,738 MWh of power can be generated and that $4,540tCO_2eqcan$ be saved. Regarding the economic effect, the net present value of the facility was shown to be 2,247,389,020 KRW. As the net present value was shown to be positive, we believe that the installation of a photovoltaic power generation facility in an unused space would have a positive economic effect. We found the net present value following the fluctuation of the SMP price to be positive, though there was some variation. However, as the economic efficiency was shown to be low because the net present value in relation to the maintenance costs was negative, we believe that maintenance costs must be taken fully into account when evaluating economic efficiency. In particular, as subsidies can be used to cover maintenance costs which must be factored into photovoltaic power generation, we believe that photovoltaic power generation can have an economic effect. Because spaces not currently in use can have a positive economic effect as renewable energy power generation facilities, and can also contribute to the reduction of greenhouse gas emissions, unused spaces are thought to greatly help local governments to cope with climate change as well as reinforcing their related capabilities. We believe our study will help local governments with decisions relating to unused real estate utilization in the future.

A Study on HVDC and BESS Application for High Penetration of Renewable Energy Sources (제주지역 재생에너지 수용을 위한 HVDC 및 BESS 활용에 관한 연구)

  • Kwak, Eun-Sup;Min, Jae-Hyun;Jung, Ho-Chul;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1339-1348
    • /
    • 2021
  • There are variety of reasons for renewable energy curtailment, including lack of transmission availability and grid system stability. In the Jeju island region, there are many cases in which the supply of electricity is already increased compared to the demand for electricity due to the increase of solar and wind power generation facilities, and accordingly, the number of curtailments for wind power generation is increasing. This research aims to find the direction of efficient reception of renewable energy and stable operation of the power system using HVDC(High Voltage Direct Current) and BESS(Battery Energy Storage System) facilities that are in charge of power supply in Jeju island. And the paper suggests a practical operation plan for optimal system operation, and the direction of system operation of the land power system due to the expansion of solar and wind power generation facilities in the future.

A Study on the Fault Analysis of the LVDC Using PSCAD/EMTDC (PSCAD/EMTDC를 활용한 LVDC 고장분석)

  • Kim, Soo-Hwan;Choi, Gyu-Wan;Moon, Jong-Fil;Kim, Tae-Hoon;Kim, Ju-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.219-223
    • /
    • 2016
  • DC microgrid system is attracted attention in the world, because DC distribution system is more energy efficient than AC distribution system. To analyse the contribution effects of distributed generation(DG) in LVDC distribution system through modeling the Rectifier, DC/DC converter, Energy Storage System(ESS) and Photovoltaic(PV). using PSCAD/EMTDC. This paper analyses fault response characteristics in LVDC distribution system according to the interconnection and islanding operation of DG. Based on research results on the paper, direction for development of fault current reduction method for LVDC distribution system is suggested.

A Study on Operating Characteristics and Design Factors of Floating Photovoltaic Generating Facilities (수상태양광 발전시스템의 운영특성 및 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1532-1539
    • /
    • 2017
  • The floating photovoltaic system is a new concept in the renewable energy technology. That is similar to land based photovoltaic technology except floating system. So the system needs buoyant objects, mooring, ect, besides modules and supports, and that is able to withstand in water level changes and wind strength. Therefore the floating photovoltaic system is much different from land photovoltaic system. K-water (Korea Water Resources Corporation) has been operating two floating photovoltaic system that's capacity is 100 kW and 500 kW respectively since in summer 2011 for commercial generation, and have construction project for 2,000 kW in Boryeong multipurpose Dam and other areas. Furthermore K-water was developing a tracking-type floating photovoltaic system at Daecheong multipurpose Dam and developed and installed an ocean floating photovoltaic demonstration plant at Sihwa Lake in October 2013 for R&D. In this paper, we introduce that structure of floating photovoltaic system include buoyant structure, mooring system and auxiliary device. Especially the rope which is in part of mooring should be always maintain tension under any water level. Also we explain about structure design concept to wind load in an every loading condition and a kind of structure materials and PV structure types used in water environment. Especially ocean floating PV system is affected by tidal current and typhoon. So there are considering the elements in design. Finally we compare with floating and land photovoltaic on power amount. As a result of that we verified the floating photovoltaic system is more about 6.6~14.2 % efficiency than a general land photovoltaic system.