The Analysis of Electrical Characteristics of PV Module according to Mechanical Load Test (태양전지모듈의 기계적 하중시험에 따른 전기적 특성 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.247-251
    • /
    • 2008
  • In this paper. we analyze electrical characteristics of photovoltaic module according to mechanical load test. Using the equipment for giving load on the surface of module, dark current-voltage is measured. By varying load from 0kg to 206kg, slight different I-V curve is detected. From this, reduced shunt resistance is roughly calculated and micro crack is assumed to be happened. system Through this experiment, periodic external force on PV module might give an negative effect. The detailed analysis is described in the following paper.

  • PDF

Parallel operating technique for the stand alone PV PCS (독립형 태양광 인버터의 병렬 운전 기법)

  • Jeong, Ku-In;Kwon, Jung-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.9-15
    • /
    • 2015
  • In this paper, a parallel operating technique for the stand alone photovoltaic (PV) power conditioning system (PCS) is proposed. The proposed parallel operating technique can increase the power rating of the system easily. Also, it provide three-phase connection function. The proposed technique does not separated master and slave system. Also, it does not use the separated synchronization line. Therefore, the PCS can supply continuous power even if one of the PCS breaks down. This technique is composed of a phase locked loop (PLL) control, droop control, current limit control and etc. Experimental result obtained on 2-kW prototype to verify the proposed technique.

A Study on the Multi-level PV-PCS Using Cascade 3-Phase Transformer (직렬형 3상 변압기를 이용한 다중레벨 PV-PCS)

  • Kim, Ki-Seon;Song, Sung-Geun;Cho, Su-Eog;Choi, Joon-Ho;Kim, Kwang-Heon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2359-2369
    • /
    • 2009
  • The study on the multi-level inverter has been increasingly progressing to reduce the switching loss and improve the THD of output current in photovoltaic inverter. Recently, the main topics of multi-level inverter are to reduce the number of devices maintaining the power quality. Therefore, the novel topology was proposed for these problem which is composed of the isolated H-bridge multi-level inverter using the three phase low frequency transformer. The proposed multi-level inverter may not be need for a independent DC power, diode and capacitor. Specially, It has a advantage in generating high voltage source. The proposed approach is verified through simulation and experiment.

A Study on Synchronized AC Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic Effect

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Kim, Jong-Lae;Jang, Byong-Gon
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.547-553
    • /
    • 1998
  • In this paper, we composed of utility interactive pv generation system of voltage source inverter, and represented uninterrutible power supply (UPS) equipment maintaining constant voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to dc side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF

Application Necessity of the Active Filter Function to Photovoltaic Power Generation System installed in Building Systems (태양광발전시스템이 설치된 대전력 수용가의 Active Filter기능 적용의 필요성)

  • Seong, Nak-Gueon;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.277-280
    • /
    • 2002
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. There are already a lot of PV power generation systems installed in building systems whose harmonics are the worst object for distribution systems as a utility interactive system and also it tends to spread out continuously. In this paper, the authors propose a multy-function inverter control strategy which puts a shunt active filter function to the power inverter of the PV power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of hypothetical power system using PSCAD/EMTDC.

  • PDF

The Efficiency Analysis of Tracking-Type Floating PV System (추적식 수상 태양광 발전 시스템 성능 분석)

  • Yang, Yoen Won;Jeong, Seon Ok;Shin, Hyun Woo;Lee, Kil Song
    • Current Photovoltaic Research
    • /
    • v.1 no.2
    • /
    • pp.122-125
    • /
    • 2013
  • The Floating Photovoltaic System was installed on the surface of water. There were some researches in this subject. But there was not many studies with experiment on a high waterproof Floating Photovoltaic modules. The aim of this study was to analyze the performance of the Floating Photovoltaic System. For this experiment, a high waterproof Floating Photovoltaic modules were designed and applied to the module capacity of 10 kW Tracking-Type structure. The experiment results indicated the performance of the daily production is 51.6 kW; the production capacity of Floating Photovoltaic System is expected to be 23% higher than that of the ground-mounted photovoltaic system.

Low-Power Cool Bypass Switch for Hot Spot Prevention in Photovoltaic Panels

  • Pennisi, Salvatore;Pulvirenti, Francesco;Scala, Amedeo La
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.880-886
    • /
    • 2011
  • With the introduction of high-current 8-inch solar cells, conventional Schottky bypass diodes, usually adopted in photovoltaic (PV) panels to prevent the hot spot phenomenon, are becoming ineffective as they cause relatively high voltage drops with associated undue power consumption. In this paper, we present the architecture of an active circuit that reduces the aforementioned power dissipation by profitably replacing the bypass diode through a power MOS switch with its embedded driving circuitry. Experimental prototypes were fabricated and tested, showing that the proposed solution allows a reduction of the power dissipation by more than 70% compared to conventional Schottky diodes. The whole circuit does not require a dedicated DC power and is fully compatible with standard CMOS technologies. This enables its integration, even directly on the panel, thereby opening new scenarios for next generation PV systems.

Power Loss Analysis of Interleaved Soft Switching Boost Converter for Single-Phase PV-PCS

  • Kim, Jae-Hyung;Jung, Yong-Chae;Lee, Su-Won;Lee, Tae-Won;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.335-341
    • /
    • 2010
  • In this paper, an interleaved soft switching boost converter for a Photovoltaic Power Conditioning System (PV-PCS) with high efficiency is proposed. In order to raise the efficiency of the proposed converter, a 2-phase interleaved boost converter integrated with soft switching cells is used. All of the switching devices in the proposed converter achieve zero current switching (ZCS) or zero voltage switching (ZVS). Thus, the proposed circuit has a high efficiency characteristic due to low switching losses. To analyze the power losses of the proposed converter, two experimental sets have been built. One consists of normal devices (MOSFETs, Fast Recovery (FR) diodes) and the other consists of advanced power devices (CoolMOSs, SiC-Schottky Barrier Diodes (SBDs)). To verify the validity of the proposed topology, theoretical analysis and experimental results are presented.

Development of PV Module Integrated Type Low Voltage Battery Charger (MPPT 제어를 적용한 태양광 모듈 집적형 저전압 배터리 충전 장치 개발)

  • Kim, Dong-Hee;Shin, Seung-Min;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.168-169
    • /
    • 2012
  • 본 논문에서는 Cascade Buck-Boost 컨버터를 사용한 모듈 직접형 컨버터 (Module Integrated Converter, MIC)를 이용하여 독립형으로 저전압 배터리를 충전할 수 있는 알고리즘을 제안하고 이를 검증한다. 제안한 알고리즘은 입력 조건의 변화를 고려하여 MPPT 충전 동작 및 Constant Current (CC) - Constant Voltage (CV) 제어를 수행할 수 있어 배터리를 항상 최대의 전력으로 충전할 수 있게 한다. 제안한 충전 장치는 150W급 PV Module을 사용하여, 98.4%의 고효율 획득 및 알고리즘 성능을 검증한다.

  • PDF

Sensorless Current Balancing and MPPT Control For Photovoltaic AC Module Type Interleaved Flyback Inverter (태양광 AC 모듈형 인터리브드 플라이백 인버터에서의 입력 단 센서를 제거한 최대 전력점 추종 및 전류 평형 제어 기법)

  • Kang, Ju-Suk;Kim, Young-Ho;Youn, Sun-Jae;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.501-502
    • /
    • 2012
  • 본 논문에서는 입력 단 센서를 제거한 태양광 AC 모듈 인터리브드 플라이백 인버터의 최대 전력점 추종 및 전류 평형 제어 기법을 제안한다. 기존 제어 방식들의 수행을 위해서는 입력 전압 $V_{pv}$, 입력 전류 $I_{pv}$ 센서와 각 상 스위치 단의 전류 센서들이 필요하나 4개의 센서와 주변 회로는 AC 모듈의 사이즈, 부피 및 가격을 증가시킨다. 이러한 문제점들을 해결하기 위해 제안하는 방식은 각 상의 전류 센서만을 사용하여 최대 전력점 추종 및 전류 평형 제어를 동시에 수행한다. 제안한 시스템의 타당성을 이론적 분석과 시뮬레이션을 통해 검증한다.

  • PDF