• Title/Summary/Keyword: PV Systems

Search Result 601, Processing Time 0.027 seconds

Maximum Power Point Tracking for Photovoltaic System Using Fuzzy Logic Controller

  • Abo-Khalil A.G.;Lee D.C.;Seok J.K.;Choi J.W.;Kim H.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.503-506
    • /
    • 2003
  • The photovoltaic generators have a nonlinear V-I characteristics and maximum power points which vary with the illumination levels and temperatures. Using maximum power point tracker with the intermediate converter can increase the system efficiency by matching the PV systems to the load. A novel MPPT control for photovoltaic system is proposed. The system input parameters are (dP, dI, and last incremental of duty ratio $L\deltaD$)and the output is the new incremental value (new ${\deltaD}$) according to the maximum power point under various illumination levels. Using fuzzy logic controller allows extracting the maximum power rapidly and without significant oscillations. Also FLC provides excellent features such as fast response, good performance and the ability to change the fuzzy parameters to improve control system.

  • PDF

Development of Interconnection Algorithm for PV Systems in Distribution System (태양광발전의 배전계통 연계 알고리즘 개발에 관한 연구)

  • Park Jae-Ho;Rho Dae-Seok;Oh Yong-Taek;Hong Sangeun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.128-131
    • /
    • 2005
  • 본 논문에서는 정해진 형태의 정보를 입력하면 태양광, 풍력 등의 분산형전원의 도입 및 운용에 대한 각종 정보를 상세하고 전문적(설계나 감리, 운용자 등)인 측면에서 제공받을 수 있는 시스템의 알고리즘을 개발하고자 한다. 구체적으로는 분산형전원의 계통연계 시에 발생할 수 있는 정상, 비정상(사고), 전력품질에 대한 9개의 항목으로 전력용량, 전기방식, 역률, 뱅크 역조류, 상시전압변동, 순시전압변동, 플리커, 단락용량, 연계가능용량 등이며, 분산형전원의 배전계통에의 연계 적합 여부를 종합적으로 판단하는 시스템이다.

  • PDF

Development of Remote Control System for PV systems Based on Programmable Logic Controller (PLC를 이용한 태양광전원 단지의 원격제어시스템 구축)

  • Ryu, Kyung-Sang;Song, Suk-Hwan;Kim, Seob-Han;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.81-84
    • /
    • 2011
  • 본 논문에서는 기존의 배전계통에 태양광, 풍력 등과 같은 신재생에너지 전원을 연계 시, 발생할 수 있는 문제점들을 효율적으로 유지관리하기 위해 무선 네트워크를 이용한 원격 제어장치를 제작하였다. 이 제어장치는 모의 태양광전원장치를 포함한 모의 배전계통장치와 PLC에 기반한 원격제어장치로 구성된다. 여기서 제어장치는 크게 2개의 기능으로 구성되는데, 원격지의 PLC로 제어 신호를 보내는 HMI(Autobase)를 이용한 제어부와 이 신호를 받아 동작 전원을 공급하는 PLC제어부로 구성된다. 본 논문에서는 상기의 장치를 이용하여 원격지에 설치된 태양광단지의 보수유지 관리에 필요한 무선 네트워크 원격제어의 기술적인 대안을 마련하였고, 스마트그리드 구축에 기여할 수 있음을 확인하였다.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Design of Hybrid Type Streetlight for Railway Station with Renewable Energy (신재생에너지를 이용한 철도역사용 복합형 가로등 설계)

  • Yoon, Yong-Ho;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2103-2108
    • /
    • 2016
  • Energy saving is as important as developments of green energy and alternative energy. This paper describes design of hybrid type streetlight for railway station with renewable energy as photovoltaic, wind, secondary battery. In designing hybrid type streetlight for railway station, generation energy with renewable energy and reliability is strongly needed to meet the demand of railway station. In order to achieve the high performance of a streetlight, photovoltaic, wind and secondary battery system, PV tracker, monitoring and GUI system with logging function are designed. To verify of performance of hybrid type streetlight for railway station, we have demonstration test to get of generation energy and flow of energy and the results are present in this paper.

The Proportional Resonant Controller for Improving the Current Distortion of the Dual buck inverter in DCM Section Connected grid system with harmonic voltage (고조파 전압이 포함된 계통과 연계된 듀얼벅 인버터의 DCM 구간에서 전류 왜곡 개선을 위한 비례공진 제어기)

  • Choi, Minjae;Cho, Younghoon;Choi, Jinuk;Moon, Youngmin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.286-287
    • /
    • 2018
  • Recently, the development of renewable energy using solar energy is drawing attention. One of these PV systems, the Dual buck Inverter, is one of the topologies used in conjunction with the system, characterized by high efficiency and shoot-through reduction. However, current distortion appears severely in grid connection. So, in this paper, the method of compensation through PR controller was verified through simulation as an analysis of current distortion components and a control method to improve them.

  • PDF

The Performance Evaluation of Photovoltaic-integrated Lightshelf Systems (PV 일체형 태양광발전 광선반시스템의 성능평가)

  • Park, Hoon;Chung, Yu-Gun;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.129-134
    • /
    • 2012
  • The lightshelf system, a daylighting device, has been applied to improve the visual environment by optimal light distributions and intense illumination levels of a interior. Also, The photovoltaic is one of the most important sustainable technologies appliable to architectures. This study aims to evaluate the performance of photovoltaic integrated lightshelf system. For the study, the 1/5 scaled office models were made and the field tests were experimented under clear sky conditions. The power ratio has been analyzed to evaluate the performance of photovoltaic integrated lightshelf system. As results, the power performance was high on photovoltaic lightshelf installation angle $0^{\circ}$. And the performance was reduced on 23(%) by installation angle $15^{\circ}$ and 63(%) by installation angle $30^{\circ}$.

Output Power Analysis for Active Frequency Drift Method (AFD 기법의 출력전력 분석)

  • Lee, Ki-Ok;Choi, Ju-Yeop;Choy, Ick;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.297-302
    • /
    • 2009
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. In this paper, active frequency drift (AFD) method, one of the anti-islanding analyzed by current magnitude compensation and calculation of RMS value of the output power.

  • PDF

A study on the measurements and analysis of harmonics obtained from 5kW PV systems (태양광발전 5kW에서 발생하는 전압, 전류고조파 실측 분석)

  • Yoon, Gi-Gab;Cho, Min-Ho;Kim, Sang-Jun;Jang, Sang-Ok;Ahn, Jeong-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.230-232
    • /
    • 2003
  • 본 논문은 최근 대체에너지원으로 각광받고 있는 주택용 태양광발전시스템에 전력변환 장치로 이용되고 있는 계통연계형 5kW 태양광 인버터에 대한 현장 실계통의 고조파를 측정하여 전압 및 전류 고조파왜형률에 대한 분석을 시행하였다.

  • PDF

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF