• Title/Summary/Keyword: PV Module and Inverter

Search Result 63, Processing Time 0.022 seconds

Photovoltaic Micro Converter Operated in Boundary Conduction Mode Interfaced with DC Distribution System

  • Seo, Gab-Su;Shin, Jong-Won;Cho, Bo-Hyung;Lee, Kyu-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.44-45
    • /
    • 2011
  • Research on photovoltaic (PV) generation is taking a lot of attention due to its infinity and environment-friendliness with decrease of price per PV cell. While central inverters connect group of PV modules to utility grid in which maximum power point tracking (MPPT) for each module is difficult, micro inverter is attached on each module so that MPPT for individual modules can be easily achieved. Moreover, energy generation and consumption efficiency can be much improved by employing direct current (DC) distribution system. In this paper, a digitally controlled PV micro converter interfacing PV to DC distribution system is proposed. Boundary conduction mode (BCM) is utilized to achieve zero voltage switching (ZVS) of active switch and eliminate reverse recovery problem of passive switch. A 120W prototype boost PV micro converter is implemented to verify the feasibility and experimental results show higher than 98% efficiency at peak power and 97.29% of European efficiency.

  • PDF

A novel high performance interactive inverter using two module inverter (2단 인버터를 사용한 고성능 연계형 인버터)

  • Kim, Ki-Seon;Lee, Min-Jung;Park, Sung-Jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.171-174
    • /
    • 2008
  • In this paper, interactive inverter in series 2 module inverters is proposed. One of two inverters makes equivalent voltage. Another removes harmonics, contained in source voltage, through control inductor current. As a result, it remains only basic frequency voltage to produce the purely sinusoidal current wave. Using 2 module inverters is verified with simulation.

  • PDF

An analysis on the operating characteristics of 50kW Photovoltaic Power System (50 kW급 계통연계형 태양광 발전시스템 장기 실증 운전)

  • Kim, Y.S.;Ahn, K.S.;Lim, H.C.;Oh, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1788-1790
    • /
    • 2005
  • In this paper, an operating characteristics of a 50 kW gird-connected photovoltaic(PV) power system was analysed from 2000 to 2004. The construction of the PV system includes a 3-phase inverter for grid connection, PV module, distribution box, and data monitoring system. The major results of the demonstration test of the 50 kW class gird-connected PV system showed that efficiency of PV system was 11.13%, and the conversion efficiency of the inverter was 92% at a 50% load.

  • PDF

Installation and Performance Evaluation of 100kWp PV System in Tibet (중국 티베트지역의 100kWp급 태양광발전시스템 실증연구)

  • Kim, Seok-Ki;Yun, Jae-Ho;Lee, Jeong-Chul;Aha, Se-Jin;Yoon, Kyung-Hoon;Song, Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.125-129
    • /
    • 2006
  • This paper presents the isolation and performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module by using Koreans solar cells, constructed site and built control house.

  • PDF

Development of PV-Power-Hardware-In-Loop Simulator with Realtime to Improve the Performance of the Distributed PV Inverter (분산전원형 PV 인버터 성능 개선을 위한 실시간 처리기반의 PV-Power-Hardware-In-Loop 시뮬레이터 개발)

  • Kim, Dae-Jin;Kim, Byungki;Ryu, Kung-Sang;Lee, Gwang-Se;Jang, Moon-Seok;Ko, Hee-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.47-59
    • /
    • 2017
  • As the global warming threats to humanity, renewable energy is considered the key solution to overcome the climate change. In this circumstance, distributed PV systems are being expanded significantly its market share in the renewable energy industry. The performance of inverter is the most important component at PV system and numerous researches are focusing on it. In order to improve the inverter, PV simulator is an essential device to experiment under various load and conditions. This paper proposes the PV Power-Hardware-In-Loop simulator (PHILS) with real-time processing converted electrical and mathematical models to improve computation speed. Single-diode PV model is used in MATLAB/SIMULINK for the PV PHILS to boosting computation speed and dynamic model accuracy. In addition, control algorithms for sub-components such as DC amplifier, measurement device and several interface functions are implemented in the model. The proposed PV PHILS is validated by means of experiments with commercial PV module parameters.

Installation and Performance Evaluation of 100kWp PV System in Tibet (중국 티베트지역의 100kWp급 태양광발전시스템 실증연구)

  • Kim Seok-Ki;Yun Jae-Ho;Lee Jeong-Chul;Ahn Se-Jin;Yoon Kyung-Hoon;Song Jin-Soo
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.16-22
    • /
    • 2006
  • This paper present the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea.

  • PDF

Design and Control of Interleaved Boost converter for Multi-string PV Inverter (멀티스트링 태양광 인버터용 인터리브드 부스트 컨버터의 설계 및 제어)

  • Kang, Young-Ju;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.538-543
    • /
    • 2011
  • In this paper, design and control of an interleaved boost converter for multi-string PV Inverter are discussed. Interleaved Boost converter can reduce current ripples at input and output side by cancelling an each phase of inductor currents. Therefore, it contributes to increase efficiency and downsize the whole system volume, cost. One of the advantages of the multi-string system is easy to expand power capacity by connecting the converter modules in parallel. In order to reduce current ripples, the inductor currents on each phase are controlled independently in the converter module, and communication between the converter modules is required for further ripple current reduction. Current control algorithm for the balance of the each phase ripple currents and synchronization of the converter modules based on communication are proposed and implemented in the DSP programming. 10kW prototype of the multi-string converter module is assembled and experimental results are presented to verify the proposed ripple current reduction methods.

The Monitoring System with PV Module-level Fault Diagnosis Algorithm (태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템)

  • Ko, Suk-Whan;So, Jung-Hun;Hwang, Hye-Mi;Ju, Young-Chul;Song, Hyung-June;Shin, Woo-Gyun;Kang, Gi-Hwan;Choi, Jung-Rae;Kang, In-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.3
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

Status Diagnosis Algorithm for Optimizing Power Generation of PV Power Generation System due to PV Module and Inverter Failure, Leakage and Arc Occurrence (태양광 모듈, 인버터 고장, 누설 및 아크 발생에 따른 태양광발전시스템의 발전량 최적화를 위한 상태진단 알고리즘)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.4
    • /
    • pp.135-140
    • /
    • 2024
  • It is said that PV power generation systems have a long lifespan compared to other renewable energy sources and require little maintenance. However, there are cases where the performance expected during initial design is not achieved due to shading, temperature rise, mismatch, contamination/deterioration of PV modules, failure of inverter, leakage current, and arc generation. Therefore, in order to solve the problems of these systems, the power generation amount and operation status are investigated qualitatively, or the performance is comparatively analyzed based on the performance ratio (PR), which is the performance index of the solar power generation system. However, because it includes large losses, it is difficult to accurately determine whether there are any abnormalities such as performance degradation, failure, or defects in the PV power generation system using only the performance coefficient. In this paper, we studied a status diagnosis algorithm for shading, inverter failure, leakage, and arcing of PV modules to optimize the power generation of PV power generation systems according to changes in the surrounding environment. In addition, using the studied algorithm, we examined the results of an empirical test on condition diagnosis for each area and the resulting optimized operation of power generation.

Classification of Grid Connected Transformerless PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families

  • Ozkan, Ziya;Hava, Ahmet M.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.256-267
    • /
    • 2015
  • Grid-connected transformerless photovoltaic (PV) inverters (TPVIs) are increasingly dominating the market due to their higher efficiency, lower cost, lighter weight, and reduced size when compared to their transformer based counterparts. However, due to the lack of galvanic isolation in the low voltage grid interconnections of these inverters, the PV systems become vulnerable to leakage currents flowing through the grounded star point of the distribution transformer, the earth, and the distributed parasitic capacitance of the PV modules. These leakage currents are prohibitive, since they constitute an issue for safety, reliability, protection coordination, electromagnetic compatibility, and module lifetime. This paper investigates a wide range of multi-kW range power rating TPVI topologies and classifies them in terms of their leakage current attributes. This systematic classification places most topologies under a small number of classes with basic leakage current attributes. Thus, understanding and evaluating these topologies becomes an easy task. In addition, based on these observations, new topologies with reduced leakage current characteristics are proposed in this paper. Furthermore, the important efficiency and cost determining characteristics of converters are studied to allow design engineers to include cost and efficiency as deciding factors in selecting a converter topology for PV applications.