• 제목/요약/키워드: PV Inverter

검색결과 344건 처리시간 0.027초

계통연계형 태양광발전 인버터를 위한 주기적인 영전류 구간을 가지는 새로운 AFD 단독운전 검출기법 (Novel AFD method of islanding detection with a periodic zero current for improving on islanding detection for grid-connected Photovoltaic inverters)

  • 고문주;최익;최주엽;송승호;이기옥
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.17-23
    • /
    • 2006
  • This paper proposes a novel active frequency drift (AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. In this paper, injecting the periodic zero current into the basic AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 1547 with various load conditions. Detection of islanding is verified using simulation tool PSIM.

주택보급형 태양전지 양산기술 및 계통연계 3kW 태양광 시스템 상용화 기술개발 (Commercial Technology Development of Solar Cell and Grid Connected 3kW PV System for PV House Supply)

  • 이박일;문상진;윤종호;김흥근;유권종;윤태영;김신섭;배상순;이준신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.151-164
    • /
    • 2005
  • 태양전지는 요구전력의 필요에 따라 직 병렬로 연결하여 태양전지 모듈(solar cell module)로 제품화한다. 태양전지가 실제로 전자제품에 연결해서 사용하기 위해서는 주변장치(BOS, Balance of System)가 사용된다. 또한 일사량의 강도에 따라 불균일한 직류전기가 발생되므로, 태양광발전시스템은 모듈을 직 병렬로 연결한 태양전지 어레이(solar cell array)와 안정된 전기공급을 위한 전력조정기(power conditioning system, 이하 PCS)가 필요하다. 또한 직류가 아닌 교류를 필요로 하는 응용제품에는 직 교류변환장치 인버터(inverter)를 필요로 한다. 본 과제는 전시를 위한 연구개발 목적보다는 태양광 시스템 보급 양산기술에 중심을 두어 태양광 산업경제를 활성화 하고자한다. 따라서 본 과제는 기존에 연구개발과 특수목적 시장 중심인 초고효율 태양전지 개발보다 경제적인 기여도와 파급효과가 크다.

  • PDF

모듈형 계통연계 태양광 PCS (Modular Line-connected Photovoltaic PCS)

  • 서현우;권청민;김응호;권봉환
    • 전력전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.119-127
    • /
    • 2008
  • 본 논문에서는 모듈형 계통연계 태양광 PCS (photovoltaic power conditioning system)를 제안하였다. 능동-클램프 회로와 듀얼 직렬-공진 정류 회로를 이용하여 높은 입출력 전압 비를 효과적으로 구현하고 효율을 높인 승압형 DC-DC 컨버터를 제안하였다. 최대 전력점 추종 특성을 개선한 IncCond (incremental conductance) 방식의 MPPT (maximum power point tracking) 알고리즘을 사용하였다. 이 때 DC 전류 센서를 사용하지 않고 태양전지 모듈 (PV module)의 전류를 예측한다. 선형화 기법을 사용한 출력 전류 제어기로 인버터를 제어하여 단위 역률을 실현하였다. 모든 알고리즘과 제어기를 하나의 마이크로컨트롤러로 구현하고 제안된 DC-DC 컨버터와 제어기의 우수성을 실험을 통해 검증하였다.

Mitigation of Low Frequency AC Ripple in Single-Phase Photovoltaic Power Conditioning Systems

  • Lee, Sang-Hoey;An, Tae-Pung;Cha, Han-Ju
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.328-333
    • /
    • 2010
  • A photovoltaic power conditioning system (PV PCS) that contains single-phase dc/ac inverters tends to draw an ac ripple current at twice the output frequency. Such a ripple current perturbs the operating points of solar cells continuously and it may reduce the efficiency of the current based maximum power point tracking technique (CMPPT). In this paper, the ripple current generation in a dc link and boost inductor is analyzed using the ac equivalent circuit of a dc/dc boost converter. A new feed-forward ripple current compensation method to incorporate a current control loop into a dc/dc converter for ripple reduction is proposed. The proposed feed-forward compensation method is verified by simulation and experimental results. These results show a 41.8 % reduction in the peak-to peak ac ripple. In addition, the dc/ac inverter control system uses an automatic voltage regulation (AVR) function to mitigate the ac ripple voltage effect in the dc link. A 3kW PV PCS prototype has been built and its experimental results are given to verify the effectiveness of the proposed method.

PV System 기반 ESS의 최적운전을 위한 설계 및 제어 특성에 관한 연구 (A Study on the Design and Control Characteristics for Optimum Operation of the PV System-based ESS)

  • 차인수;박종복;정경환
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.19-30
    • /
    • 2016
  • In this study, realize voltage regulation $220Vac{\pm}10%$ or less, frequency fluctuation $60Hz{\pm}1%$ or less over the independent operation and grid-connected operation technologies for power stabilization relates to the ESS designed and manufactured in conjunction with solar installations and solar to compensate the output reduction due to the polarization of the solar module through the polarization prevention technology for preventing the optical module efficiency is lowered, in conjunction with the BMS inverter efficiency was more than 92%, more than 90% of the charging efficiency to the target. This study was designed in conjunction with the ESS solar power plants, grid-connected operation and independent operation, Peak-Cut, it can stabilize the grid via the Peak-Shifting operation

오프셋 전압을 이용한 계통 연계형 3상 3레벨 T-type 태양광 PCS의 중성점 전압 불평형 보상 (Compensation of Unbalanced Neutral Voltage for Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS Using Offset Voltage)

  • 박관남;최익;최주엽;이영권
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.1-12
    • /
    • 2017
  • The DC link of Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS (PV-PCS) consists of two series connected capacitors for using their neutral voltage. The mismatch between two capacitor characteristics and transient states happened in load change cause the imbalance of neutral voltage. As a result, PV-PCS performance is degraded and the system becomes unstable. In this paper, a mathematical model for analyzing the imbalance of neutral voltage is derived and a compensation method using offset voltage is proposed, where offset voltage adjusts the applying time of P-type and N-type small vectors. The validity of the proposed methods is verified by simulation and experiment.

A Novel Active Anti-islanding Method for Grid-connected Photovoltaic Inverter

  • Jung, Young-Seok;Choi, Jae-Ho;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.64-71
    • /
    • 2007
  • This paper proposes a novel active frequency drift (AFD) method to improve the islanding detection performance with minimum current harmonics. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning the safety hazards and possible damage to other electric equipment, anti-islanding methods have been described. The AFD method that uses chopping fraction (cf) enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD method is inefficient and causes difficulty in designing the appropriate cf value to meet the limit of harmonics. In this paper, the periodic chopping fraction based on a novel AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also better performance of islanding detection compared with the conventional AFD method.

태양광 MIC 시스템의 효율향상을 위한 새로운 Active Clamp 스위칭 기법 (A Novel Active Clamp Switching Method To Improve of Efficiency For Photovoltaic MIC)

  • 박병철;박지호;송성근;박성준;신중린
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.477-484
    • /
    • 2013
  • This paper proposes a novel switching method of active clamp snubber for efficiency improvement of PV module integrated converter(MIC) system. Recently, MIC solar system is researched about the efficiency and safety. PV MIC system is used active clamp method of snubber circuit for the price and reliability of the system. But active clamp snubber circuit has the disadvantage that system efficiency is decreased for switch operating time because of heat loss of resonant between snubber capacitor and leakage inductance. To solve this problem, this paper proposes a novel switching method of the active clamp. The proposed method is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time and through simulations and experiments proved the validity.

계통연계형 태양광발전시스템의 새로운 단독운전 검출기법 (Novel islanding detection method for grid connected PV system)

  • 정영석;소정훈;유병규;유권종;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1705-1707
    • /
    • 2005
  • This paper proposes a novel active frequency drift(AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic(PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction(cf) enables the islanding detection to drift up(or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD methods, which have a certain value of cf only, is inefficient and difficult to design the appropriate cf value analytically to meet the limit of harmonics. In this paper, the periodic chopping fraction based on an AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with the power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also good performance of islanding detection compare with the conventional AFD method.

  • PDF

회생모드가 없는 단일전원 27레벨 캐스케이드 H-브리지 인버터 (A Pre-Regulated Single-Sourced 27-level ACHB Inverter without Regeneration)

  • 모하나 순다 마노하란;아쉬라프 아흐무드;이춘구;박종후
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.95-96
    • /
    • 2015
  • In this paper, a single-sourced PV PCS using the trinary asymmetric MLI with a single-ended pre-regulator is proposed. Trinary based asymmetric CHB inverters provide higher output levels for the same number of cells compared to other CHB inverters. However, there is an issue of regeneration with trinary asymmetric inverters and this complicates the system with requirement of bi-directional converters at the input. Modified commutation strategies have been used to remove the regeneration issue with compromise in THD. The single-ended pre-regulator provides the isolated dc-link voltage for the individual H-bridge cells with the advantage of having a single switch and magnetic component. This implementation increases the magnetic utilization of the inductor core and reduces the switching loss in the pre-regulator and also the reduced parts count contributes to the cost competiveness of the proposed PCS. The proposed PV PCS has been verified using simulation results in this paper.

  • PDF