• Title/Summary/Keyword: PV/T

Search Result 162, Processing Time 0.027 seconds

Optical Simulation Study on Indoor Organic Photovoltaics with Textured Electrodes towards Self-powered Photodetector

  • Biswas, Swarup;Kim, Hyeok
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.236-239
    • /
    • 2019
  • In this work, we performed an optical simulation study on the performance of a PMDPP3T:PCBM based on an organic photovoltaic (PV) device. The virtual PV device was developed in Lumerical, finite-difference time-domain (FDTD) solutions. Different layers of the PV cell have been defined through the incorporation of complex refractive index value of those layers' constituent materials. During the simulation study, the effect of the variation active layer thickness on an ideal short circuit current density ($J_{sc,ideal}$) of the PV cell has been, first, observed. Thereafter, we have investigated the impact of surface roughness of a transparent conducting oxide (TCO) electrode on $J_{sc,ideal}$ of the PV cells. From this simulation, it has been observed that the $J_{sc,ideal}$ value of the PV cell is strongly dependent on the thickness of its active layer and the photon absorption of the PV cell has gradually decreased with the increment of the TCO's surface roughness. As a result, the capability of the PV device has been reduced with the increment of the surface roughness of the TCO.

Development of Wireless IoT Sensors for Individual Photovoltaic Module Monitoring (태양광 모듈 개별 모니터링을 위한 무선 IoT센서)

  • Park, Jongsung;Kim, Changheon;Lee, Jiwon;Kim, Jihyun;Yoo, Sanghyuk;Yang, Bum Seung
    • Current Photovoltaic Research
    • /
    • v.9 no.3
    • /
    • pp.106-109
    • /
    • 2021
  • In order to perform photovoltaic (PV) operation and management (O&M) efficiently, individual PV module monitoring is becoming more important. In this research, we developed wireless IoT sensor which can monitor individual photovoltaic modules. This IoT sensor can detect the output voltage, current and module temperature of individual modules and provide monitored data by wireless communication. Measured voltage error was 1.23%, and it shows 16.6 dBM, 0.42sec and 7.1 mA for voltage, transmittance output, response time and mean power consumption, respectively. IoT sensors were demonstrated in the test field with real climate environment condition and each of 5 sensors showed precise results of voltage, current and temperature. Also, sensors were compared with commercial power-optimizers and showed result difference within 5%.

Hybrid Photovoltaic/Thermal Solar System with Pulsating Heat Pipe Type Absorber (진동형 히트파이프 흡열판이 결합된 하이브리드 태양광/열 시스템)

  • Kim, Chang-Hee;Jeon, Dong-Hwan;Kong, San-Gun;Kim, Jong-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2148-2153
    • /
    • 2007
  • The electricity conversion-efficiency of solar cell for commercial application is about 6-15%. More than 85% of the incoming solar energy is either reflected or absorbed as heat energy. Consequently, the working temperature of the photovoltaic cells increases considerably after prolonged operations and the cell's efficiency drops significantly. PV/T refers to the integration of a PV module and a solar thermal collector in a single piece of equipment. By cooling the PV module with a fluid steam like air or water, the electricity yield can be improved. At the same time, the heat pick-up by the fluid can be to support space heating or service hot-water systems. In this study, a pulsating heat pipe solar heat collector was combined with single-crystal silicon photovoltaic cell in hybrid energy-generating unit that simultaneously produced low temperature heat and heat and electricity. This experiment was investigating thermal and electrical efficiency for evaluation of a PV/T system.

  • PDF

An Experimental Study of Solar fir Roof Heating System With PVT Collector (공기식 집열 지붕 난방시스템의 실험 연구)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF

Identification of hrcC, hrpF, and maA Genes of Xanthomonas campestris pv. glycines 8ra: Roles in Pathogenicity and Inducing Hypersensitive Response on Nonhost Plants

  • Park, Byoung-Keun;Ingyu Hwang
    • The Plant Pathology Journal
    • /
    • v.15 no.1
    • /
    • pp.21-27
    • /
    • 1999
  • Nonpathogenic mutants of Xanthomonas campestris pv. glycines were generated with Omegon-Kim to isolate genes essential for pathogenicity and inducing hypersensitive response (HR). Three nonpathogenic multants and two mutants showing slow symptom development were isolated among 1,000 colonies tested. From two nonpathogenic mutants, 8-13 and 26-13, genes homologous to hrcC and hrpF of X. campestris pv. vesicatoria were identified. The nonpathogenic mutant 8-13 had a mutation in a gene homologous to hrpF of X. campestris pv. vesicatoria and failed to cause HR on pepper plants but still induced HR on tomato leaves. The nonpathogenic mutant 26-13 had an insertional mutation in a gene homologous to hrcC of X. campestris pv. vesicatoria and lost the ability to induce HR on pepper leaves but still caused HR on tomato plants. Unlike other phytopathogenic bacteria, the parent strain and these two mutants of X. campestris pv. glycines did not cause HR on tobacco plants. a cosmid clone, pBL1, that complemented the phenotypes of 8-13 was isolated. From the analysis of restriction enzyme mapping and deletion analyses of pBL1, a 9.0-kb Eco RI fragment restored the phenotypes of 8-13. pBL1 failed to complement the phenotypes of 26-13, indicating that the hrcC gene resides outside of the insert DNA of pBL1. One nonpathogenic mutant, 13-33, had a mutation in a gene homologous to a miaA gene encoding tRNA delta (2)-isopentenylpyrophosphate transferase of Escherichia coli. This indicated that tRNA modifications in X. campestris pv. glycines may be required for expression of genes necessary for pathogenicity. The mutant 13-33 multiplied as well as the parent strain did in the culture medium and in planta, indicating that loss of pathogenicity is not due to the inability of multiplication in vivo.

  • PDF

Draft genome sequences of Pseudomonas syringae pv. syringae strain WSPS007 causing bacterial shoot blight on apple (사과가지마름병원세균 Pseudomonas syringae pv. syringae WSPS007 균주의 유전체 해독)

  • Lim, Yeon-Jeong;Ryu, Duck Kyu;Kang, Min Kyu;Jeon, Yongho;Park, Duck Hwan
    • Korean Journal of Microbiology
    • /
    • v.55 no.1
    • /
    • pp.80-82
    • /
    • 2019
  • Pseudomonas syringae pv. syringae strain WSPS007 was isolated from infected twigs (Malus pumila) in 2013 in Yeongju, Gyeongbuk Province, Republic of Korea. Here, we report the draft genome sequence of WSPS007 with a chromosome size of 6,238,498 bp (59.04% G+C content). The genome comprises 5,379 CDS, 16 rRNA genes, and 65 tRNA genes. The P. syringae pv. syringae strain WSPS007 genome possesses an ice-nucleating activation (INA) gene and an antifreeze operon that may be related to frost damage by this pathogen. Thus, the genome sequence determined in this study will be useful in understanding the relationship between the outbreak of bacterial shoot blight disease and frost damage in northern Gyeongbuk Province.

A Study on the System Principle of PID Module Implementation (PID Module 구현 원리 시스템에 대한 연구)

  • 위성동;김태성;최창주;권병무
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.183-192
    • /
    • 1999
  • The derivative equation measured of a ${\Delta}MV=Kp*{(EVn-EVn-1)+\frac{1}{Ki/S}* EVn+(Kd/S)*(2PVn-1-PVn-PVn-1)}$ is used on the machine apparatus of industrial field, but this par doesn\`t able to educate now, because we didn\`t have the implementation device of PID module, so the principle implementation system of the PID Module is manufactured and developed. Through this system, the implementation system of PID Module is practiced with that the SV and the set of P, I, D is set on the derivative equation measured of PID. A things to be known of this experiment result is flow. 1)PID module is known that had to be used with the module of A/D and D/A. 2) In process of PV is approached to the SV to follow Kp, Ti and Td to cause a constant of set value on the $MVp=Kp*EV, MV=\frac{1}{Ki}{\int}EVdt, MVd=Td\frac{d}{dt}EV$, the variable rate of E and Kp, Td, Ti in that table 1 is analysed, is same as flow. (1)If Kp is high, PV is near fast to the SV, but Kp is small, PV is near slowly to the SV. (2)If Ki is shot, PV is close fast to the SV, but Ti is high, PV is close slowly to the SV (3)If Td is high, the variable rate of E press hardly when because it doesn\`t increase, but Td is small, the variable rate of E press not hardly, upper with 1), 2), PID module is supposed that be able to do the A/S and an implementation of that apparatus, and getting a success of aim that an engineer want, on control of temperature, tension, velocity, amount of flow, power of wind end so on, to get the principle of automatic implementation in industrial field with cooperation of A/D and D/A module.

  • PDF

MMP2 Gene-735 C/T and MMP9 gene -1562 C/T Polymorphisms in JAK2V617F Positive Myeloproliferative Disorders

  • Sag, Sebnem Ozemri;Gorukmez, Ozlem;Ture, Mehmet;Gorukmez, Orhan;Topak, Ali;Sahinturk, Serdar;Ocakoglu, Gokhan;Gulten, Tuna;Ali, Ridvan;Yakut, Tahsin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.443-449
    • /
    • 2015
  • Background: Myeloproliferative disorders (MPDs) are clonal hematologic malignancies originating at the level of the pluripotent hematopoietic stem cell. Matrix metalloproteases (MMPs) are proteolytic enzymes that contribute to all stages of malignancy progression. Genetic variants in the MMP genes may influence the biological function of these enzymes and change their role in carcinogenesis and progression. To our knowledge, this is the first investigation of associations between the -735 C/T and -1562 C/T polymorphisms in the MMP2 and MMP9 genes, respectively, and the risk of essential thrombocytosis (ET), and polycythemia vera (PV). Materials and Methods: The case-control study included JAK2V617F mutation positive 102 ET and PV patients and 111 controls. Polymorphisms were determined by using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and electrophoresis. Results: No statistically significant differences were detected between patient (ET+PV) and control groups regarding genotype distribution for MMP2 gene-735 C/T and MMP9 gene -1562 C/T polymorphisms and C/T allele frequency (p>0.050). Statistically borderline significance was observed between PV and control groups regarding genotype distribution for the MMP9 gene -1562 C/T polymorphism (p=0.050, OR=2.26, 95%Cl=0.99-5.16). Conclusions: Consequently this study supported that CC genotype of MMP9 gene -1562 C/T polymorphism may be related with PV even if with borderline significance.

Investigation and Analysis on the Surface Morphology of Roof-Top Photovoltaic System (평지붕 설치 태양광시스템의 표면형태 조사·분석)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.57-65
    • /
    • 2016
  • Domestic photovoltaic system for roof-top is installed towards the south at an angle of 20 to 35 degrees and the shape of PV array is divided into two kinds; a plane shape and a curved shape. This paper aims to understand an actual condition of PV facility and strengths and weaknesses of support structure production and installation and to consider the best PV surface shape by analyzing theoretical logics of these two surface shapes and architectural perspective-based realistic case studies. This study targeted 98 facilities including common houses, public institutions and education institutions. In common houses, all of 59 PV facilities have a plane surface. In public institutions, 7 of 15 PV facilities have a curved array surface and 8 PV facilities have a plane surface. In education institutions, also, 14 of 24 PV facilities have a plane array surface and 10 PV facilities have a curved surface. Most of 98 facilities have a flat roof supporting shape. However, it was found that the curved shape wasn't positive for PV generation due to the change of radial density and it was at least 10 % more expensive to produce its structure. Also, domestic general large single-plate PV facilities have problems of harmony with buildings and wind load. Therefore, it is considered that for fixed-type roof-top PV, a plane PV array shape is good for optimum generation and economic efficiency and a parallel array structure on the roof surface is favorable to wind load and snow load without being a hindrance to the building facade.

A Novel Anti-islanding Algorism for Utility Interconnection of PV System (PV 시스템의 계통연계를 위한 새로운 고립운전 방지 알고리즘)

  • Yun, Jung-Hyeok;Kim, Heung-Geun;Choi, Jong-Woo;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.271-273
    • /
    • 2005
  • Islanding of PV systems occurs when the utility grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems in an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF