• 제목/요약/키워드: PV(photovoltaic) generation system

검색결과 386건 처리시간 0.024초

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

광명역 고속철도 역사를 활용한 1.5MW급 태양광발전시스템 설계 연구 (A Study on Design of 1.5MW Photovoltaic Power Generation System using Gwangmyeong Railway Station Building)

  • 유복종;박찬배;이주
    • 한국철도학회논문집
    • /
    • 제19권5호
    • /
    • pp.592-599
    • /
    • 2016
  • 프랑스 파리에서 2015년 12월 개최된 제21차 기후변화협약 당사국총회(COP21)는 신기후체제 합의문인 "파리 협정"을 채택하였다. 이는 2020년 만료 예정인 교토의정서를 대체하는 것으로 모든 국가가 전지구적인 기후변화대응에 참여하는 것으로 국제사회는 공동의 장기 목표로 산업화 이전 대비 지구 평균 기온 상승을 $2^{\circ}C$ 보다 상당히 낮은 수준으로 유지하고 온도 상승을 $1.5^{\circ}C$ 이하로 제한하기 위한 노력을 추구하여야 하며, 모든 국가는 장기 저탄소 개발 전략을 마련하여 2020년까지 제출하는 것을 요청하고 있다. 철도교통분야에서는 저탄소화에 대한 연구를 활발히 지속적으로 진행하고 있다. 본 논문에서는 국내 고속철도 역사 중 최대 건축규모이며 2014년 기준 여객수송인원 약 7백만명을 담당하는 광명역 역사 지붕을 활용한 1.5MW급 태양광 발전시스템을 설계를 위한 연구를 다룬다. 이를 위해 최적의 태양광발전시스템 설비를 구성한 후 PVsyst소프트웨어를 활용하여 연간 예상 발전량을 산출하고 배전계통 연계시에 예상 수익을 산출하여 철도역사의 태양광발전시스템 도입에 따른 저탄소 에너지화에 대한 기여도를 분석하고자 한다.

An experimental performance analysis of a cold region stationary photovoltaic system

  • Choi, Wongyu;Warren, Ryan D.;Pate, Michael B.
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.1-28
    • /
    • 2016
  • A grid-connected photovoltaic (PV) system comprised of multicrystalline silicon (mc-Si) modules was installed in a cold climate region in the U.S. This roof-mounted stationary PV system is a real-world application of PV for building energy generation in International Energy Conservation Code (IECC) Climate Zone 5 (and possibly similar climate zones such as 6, 7 and 8), and it served the purposes of research, demonstration, and education. The importance of this work is highlighted by the fact that there has been less emphasis on solar PV system in this region of the U.S. because of climate and latitude challenges. The system is equipped with an extensive data acquisition system capable of collecting performance and meteorological data while visually displaying real-time and historical data through an interactive online interface. Experimental data was collected and analyzed for the system over a one-year period with the focus of the study being on measurements of power production, energy generation, and efficiency. The annual average daily solar insolation incident upon the array was found to be $4.37kWh/m^2$. During the first year of operation, the PV system provided 5,801 kWh (1,264 kWh/kWp) of usable AC electrical energy, and it was found to operate at an annual average conversion efficiency and PR of 10.6 percent and 0.79, respectively. The annual average DC to AC conversion efficiency of the inverter was found to be 94 percent.

Matlab/Simulink를 이용한 계통연계형 태양광발전 모델링 (Modeling of Grid-Connected Photovoltaic Generation using Matlab/Simulink)

  • 서훈철;윤영민;김선룡;이시봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.92-94
    • /
    • 2008
  • This paper introduces the modeling of grid-connected photovoltaic(PV) generation using Matiab/Simulink. The model is based on the equivalent circuit of the PV solar cell including the effects of solar irradiation and temperature changes. The PV arrays are modeled to be built up with the series/parallel combination of PV solar cell and are connected to the distribution system via an inverter. The simulation results show that the typical characteristics and outputs of the PV arrays are accurate.

  • PDF

전력계통 고장시 계통연계형 태양광발전시스템의 영향분석 (Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System)

  • 박성훈;이용식;정성원;김재현
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.69-77
    • /
    • 2019
  • Among the main functions of the grid-connected photovoltaic (PV) system, the anti-islanding operation function is a very important problem. Recently, due to the improvement in power generation efficiency and the maintenance advantages in PV system, the use of string inverter has increased so that the possibility of islanding operation has been raised. Generally, when a power system faults, the PV inverter must be disconnected from power system within 10 cycles by the anti-islanding operation function. However, in the real-time of power system, the output power of the PV system within 10cycles is effected. In this paper, we analyzed the effect of grid-connected PV system on power quality in a short time within 10 cycles on fault case of power system using the Matlab Simulink program.

상용툴을 이용한 120kW급 계통연계형 태양광발전시스템의 모델링 및 모의 해석 (Commercial Tool Based Modeling and Simulation Analysis of a Grid-Connected for 120kW Photovoltaic Generation System)

  • 황정희;안교상;김영섭;임희천;오제명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.519-520
    • /
    • 2006
  • In this paper, to evaluate the grid-connected 120kW class Photovoltaic(PV) system performance, as a consisted of solar cells, PCS, 150kVA transformer station. The paper address modeling and analysis of a grid-connected 120kW class photovoltaic generation system(PV system) PSCAD/EMTD and Psim. A PWM voltage source inverter(VIS) and its current control scheme have been implemented. A P&O(Perturbation and Observation) MPPT algorithms technique modeling has been simulated and analysed.

  • PDF

Energy Management Strategy and Adaptive Control for SMES in Power System with a Photovoltaic Farm

  • Kim, Seung-Tak;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1182-1187
    • /
    • 2014
  • This paper proposes an energy management strategy and adaptive control for superconducting magnetic energy storage (SMES) in a distribution power system with a grid-connected photovoltaic (PV) farm. Application of the SMES system can decrease the output power fluctuations of PV system effectively. Also, it can control the real and reactive powers corresponding to the scheduled reference values with adequate converter capacity, which are required at a steady-state operating point. Therefore, the adaptive control strategy for SMES plays a key role in improving the system stability when the PV generation causes uncertain variations due to weather conditions. The performance of proposed energy management strategy and control method for the SMES is then evaluated with several case studies based on the PSCAD/EMTDC$^{(R)}$ simulation.

평지붕 설치 태양광시스템의 표면형태 조사·분석 (Investigation and Analysis on the Surface Morphology of Roof-Top Photovoltaic System)

  • 이응직
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.57-65
    • /
    • 2016
  • Domestic photovoltaic system for roof-top is installed towards the south at an angle of 20 to 35 degrees and the shape of PV array is divided into two kinds; a plane shape and a curved shape. This paper aims to understand an actual condition of PV facility and strengths and weaknesses of support structure production and installation and to consider the best PV surface shape by analyzing theoretical logics of these two surface shapes and architectural perspective-based realistic case studies. This study targeted 98 facilities including common houses, public institutions and education institutions. In common houses, all of 59 PV facilities have a plane surface. In public institutions, 7 of 15 PV facilities have a curved array surface and 8 PV facilities have a plane surface. In education institutions, also, 14 of 24 PV facilities have a plane array surface and 10 PV facilities have a curved surface. Most of 98 facilities have a flat roof supporting shape. However, it was found that the curved shape wasn't positive for PV generation due to the change of radial density and it was at least 10 % more expensive to produce its structure. Also, domestic general large single-plate PV facilities have problems of harmony with buildings and wind load. Therefore, it is considered that for fixed-type roof-top PV, a plane PV array shape is good for optimum generation and economic efficiency and a parallel array structure on the roof surface is favorable to wind load and snow load without being a hindrance to the building facade.

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.