• Title/Summary/Keyword: PV(Photovoltaics)

Search Result 89, Processing Time 0.027 seconds

Parametric Analysis of Building Energy Impact of Semi-transparent PV (STPV의 건물 에너지 성능에 대한 파라메트릭 분석)

  • Kwak, In-Kyu;Mun, Sun-Hye;Huh, Jung-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.35-42
    • /
    • 2018
  • Semi-transparent Photovoltaics (STPV) works as an exterior material replacing windows as well as functioning as a electricity generator. As a result, it also affects the building's heating, cooling and lighting loads. In this study, we used the concept of Net Electricity Benefit(NEB) to conduct a parametric analysis of building energy impact of STPV. The NEB of STPV is from $-1kWh/m^2$ to $6kWh/m^2$. Since NEB represents the amount of energy increase or decrease when STPV is applied compared to the standard window, a value of 0 or less means that the demand for building energy can be increased rather than applying a general window having high thermal performance and high visible light transmittance value. Therefore, it is necessary to perform a comprehensive performance evaluation considering both the performance evaluation based on the existing power generation performance and the influence on the building energy.

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

Analysis of the Effect on Domestic PV Capacity under the REC Revision and Mandatory Supply (REC 개정과 의무공급량이 국내 태양광 설비량에 미치는 영향 분석)

  • Beak, Hun;Kim, Taesung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.6
    • /
    • pp.139-150
    • /
    • 2021
  • Currently, the RPS(Renewable Portfolio Standard) is the policy which supplies new and renewable energy. Power generation companies with large capacity should produce renewable energy or secure through the purchase of REC (Renewable Energy Certificates) as mandatory. The government has revised the REC weight several times, which weights each energy source by evaluating the economic and social value of renewable energy sources, and revised the mandatory supply ratio to gradually increase. This study helps to find the impact of policies on related industries. In this study, time-series analysis and regression analysis on the capacity of PV(Photovoltaics) facilities as a dependent variable were performed to analyze the effect of the revision of the REC weight for photovoltaic power generation and the amount of mandatory supply for renewable energy. As a result, it was statistically assessed that the revision of the REC weight and the increase in the mandatory supply has a significant effect on the increase in the amount of PV facilities.

A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems (태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구)

  • Kim, Chan-Hyeok;Park, Hyeon-Seok;Rho, Dea-Seok;Shin, Chang-Hoon;Yoon, Gi-Gab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

A Method of PLL(Phase-Locked Loop) using FFT (FFT를 이용한 위상추종 방법)

  • Ryu, Kang-Ryul;Lee, Jong-Pil;Kim, Tae-Jin;Yoo, Dong-Wook;Song, Eui-Ho;Min, Byung-Duk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.206-212
    • /
    • 2008
  • This paper proposes the PLL(Phase-Locked Loop) algorithm by a new FFT(Fast Fourier Transform) in a grid-connected PV PCS(Photovoltaics Power Conditionning System). The grid-connected inverter that is applied in a new renewable energy field needs the grid phase information for synchronism. Unlike the PLL which is normally used by three phase D-Q conversion, the preposed PLL algorithm using FFT has non-gain tuning and the powerful noise elimination by the characteristics of FFT. Both simulation and experimental result show that proposed algorithm has the good capacity.

The Economic Feasibility of Building-Integrated Photovoltaics System Installed on the Roof of Residential Building - Focused on Comparison with Construction Cost of BAPV System Depend on Roof Finishing Materials

  • Oh, Byung-Chil
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: This study was on the economic feasibility of BIPV system, focused on comparison with construction cost of BAPV system depend on roof finishing materials, and to suggest basic data on the construction cost. Method: Construction cost of BAPV system was calculated, by selecting asphalt single, flat type roof tile, color steel plate, titanium zinc plate as roof finishing material of residential building and by sum up each cost for roof finishing construction and cost for 3kWp-volumed PV module installation. Also, the economic feasibility was analysed quantitatively by comparing the cost for BIPV system construction, installing same volumed PV module instead of roof finishing materials. Result: 1. By installing BIPV system instead of the roof finishing material, the cost of construction falls ; about 19% in case of the titanium zinc plate, which is the most expensive, and about 11% in case of the color steel plate. 2. Reducing amount of the construction cost gets larger because of installing BIPV module instead of the roof finishing material, as the construction cost for roof finishing material gets higher ; therefore, it is more economical than BAPV system in terms of whole cost of construction.

Hydrothernal 방법을 이용한 PV 반사방지용 ZnO 나노 구조의 합성

  • Sin, Beom-Gi;Choe, Ji-Hyeok;Xiong, Junjie;Lee, Tae-Il;Myeong, Jae-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.28.1-28.1
    • /
    • 2010
  • 다양한 반도체 재료 중 ZnO는 3.2 eV의 넓은 밴드 갭을 통한 고효율의 단파장 전기광학 소자 응용 개발에 대한 연구가 진행중에 있으며, 60 meV의 넓은 엑시톤 결합 에너지로 인해 높은 기계적, 열적 안정성을 가진다. 또한 높은 투과성과 굴절율(n=2)을 가지며 이방성 성장을 통한 텍스처 코팅이 가능함으로 PV(photovoltaics)용 유전체 ARC(anti-reflection coating) 재료로 유망하다. 텍스처된 표면은 빛을 차단시키며, 광대역에서 반사를 억제 시킨다. 또한 나노 구조를 통한 나노 다공성 표면은 광대역에서 빛을 모으는 장점이 있으며 태양전지 효율을 극대화 시킬 수 있다. 본 연구에서는 저온 공정이 가능한 hydrothermal 방법으로 다양한 ZnO 나노 구조를 합성하였다. 사용된 합성 재료로 사용되는 zinc nitrate($Zn(NO_3)_2.6H_2O$), hexamethyltetramine(HMT, $C_6H_{12}N_4$)의 농도 및 합성 온도 변화를 통해 다양한 나노구조(나노선, 나노막대, 나노시트 등)의 형태 및 크기를 제어하였다. 이러한 구조적인 변화를 토대로 텍스처된 다공성 나노구조를 형성시키고, 그 형상과 크기 차이에 따른 AR 특성을 평가하였다. ZnO 나노 구조의 결정학적 특성은 XRD(x-ray diffractometer)를 이용하여 분석하였으며, SEM(scanning electron microscope)을 통해 나노 구조의 모양과 크기를 관찰하였다. 또한 UV-Vis spectrophotometer를 통해 나노 구조의 흡수도와 반사도를 측정하였다.

  • PDF

A study of high-efficiency rotating condensing hybrid solar LED street light module system (고효율 회전 집광형 하이브리드 태양광 LED 가로등 모듈 시스템 연구)

  • Min, Kyung-Ho;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.50-55
    • /
    • 2021
  • Solar power generation, which is one of the methods of using solar energy, has a high possibility of practical implementation compared to other renewable energy power generation, and it has the characteristic that it can generate as much power as needed in necessary places. In addition, maintenance is easy, unmanned operation is possible, and power management can be performed more efficiently if operated in a hybrid method with existing electric energy. Therefore, in this study, numerical analysis using a computer program was performed to analyze the efficient operation and performance improvement of solar energy of the rotating condensing type solar LED street lamp. As a result, the two-axis tracking type could obtain 15.23 % more electricity per year than the fixed type, and additional auxiliary power generation was required for the fixed type by 19 % per year than the tracking type. As a result of computational fluid dynamics(CFD) simulation for PV module surface temperature prediction, the The surface temperature of the Photovoltaics(PV) module incident surface was predicted to be about 10℃ higher than that of the fixed type.

Study on the Characteristics of GaInP/AlGaInP Heterojunction Photovoltaic Cells under Concentrated Illumination (집광 조건에서의 GaInP/AlGaInP 이종접합 구조 태양전지 특성 연구)

  • Kim, Junghwan
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.504-508
    • /
    • 2019
  • The feasibility of replacing the tope cell of pn GaInP homojunction with our GaInP/AlGaInP heterojunction structure in III-V semiconductor multijunction photovoltaic (MJPV) cells having the highest current conversion efficiency was investigated. The performance of photovoltaic (PV) cells grown on $2^{\circ}$ and $10^{\circ}$ off-oriented GaAs substrates were compared to each other. The PV cells on the $10^{\circ}$ off-cut substrate showed higher short-circuit current density ($J_{sc}$) and conversion efficiency values than that of using the $2^{\circ}$ one. For $2{\times}2mm^2$ area PV cell on $10^{\circ}$ off substrate, the $J_{sc}$ of $9.21mA/cm^2$ and the open-circuit voltage of 1.38 V were measured under 1 sun illumination. For $5{\times}5mm^2$ cell on $10^{\circ}$ off substrate, the conversion efficiency was decreased from 6.03% (1 sun) to 5.28% (20 sun) due to a decrease in fiill factor (FF).

Development of Stand-Alone Underground Water Pumping System using Photovoltaics System (태양광발전을 이용한 독립형 지하수 양수 시스템 개발)

  • Lee, Seung-Hun;Hwang, Jung-Hoon;Cho, Woon-Sik;Kim, Man-Il;Lee, Joon-Gee;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF