• Title/Summary/Keyword: PUSH OFF

Search Result 90, Processing Time 0.024 seconds

A Shear Bond Chracteristics of Composite Slab with Closed-Shape Deckplate (폐쇄형 데크플레이트를 사용한 합성슬래브의 전단부착 특성에 관한 연구)

  • Ju, Gi Su;Park, Sung Moo
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.557-566
    • /
    • 2001
  • Composite slab with deckplate needs sufficient bond strength between deckplate and concrete to conduct composite behavior Composite slab can transfer the shear by either chemical adhesion interface interlock, or active friction. There are several way of mechanical shear connection in composite slab. that is embossments shear connector shape of deckplate etc. Effect of mechanical interaction is deped on shape of deckplate which is to prevent peeling between deckplate and concrete and an amount of shear connector. The behavior and strength of the connection between the decking and the concrete slab due to embossments and end anchorage may be estimated using the push-off tests described in this paper We proposed the equation of shear bond strength in the composite slab It will be use to design by basic data in composite slab.

  • PDF

Change in Countermovement Jump Strategy by Varying Jump Height Based on Simplified Framework for Center of Mass Mechanics (반동을 이용한 수직 점프 시 높이 변화에 따른 운동역학 및 상변화 시점에서의 지면반력 벡터 변화)

  • Kim, Seyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.277-283
    • /
    • 2017
  • In this study, we investigated how a jumping strategy changes with an increase in the vertical jump height for a resultant ground reaction force (GRF) vector. We expected that the resultant force vector between two sequential motion phases (i.e., countermovement and push-off) of the countermovement jump would significantly change with the vertical jump height to take advantage of the resulting supportive force (i.e., an initial push-off force larger than the body weight) through the countermovement phase. Nine healthy young subjects were instructed to jump straight up to five different height levels ranging from 191 cm to 221 cm, and the kinematic and kinetic data were obtained in regular trials. The results showed that a lower center of mass position and larger resultant force vector were clearly observed in a higher jump, implying that the countermovement strategy changed with the vertical jump height to prepare for sufficient joint deviation and obtain a force advantage for larger push-off work.

Development of Reliability-Based Optimum Design of High-Speed Railway Bridges Considering Structure-Rail Longitudinal Interaction and Structure-Vehicle Interaction Using Heuristic Decision Method (Heuristic Decision Method를 이용하여 구조물-궤도 종방향 상호작용 및 구조물-차량 상호작용을 고려한 고속철도 교량의 신뢰성 최적설계 기법 개발)

  • Ihm, Yeong-Rok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.31-38
    • /
    • 2010
  • In this study, it is suggested that it has to reliability-based design methodology with respect to bridge structure-rail longitudinal interaction and bridge structure-vehicle interaction. For the structural analysis, commercial package, ABAQUS, are used for a three-dimensional finite element analysis. The optimization process utilizes a well-known optimizer, ADS(Automated Design Synthesis). Optimization technique is utilized the ALM-BFGS method for global area search and Golden Section Method for 1-D search. In general, ALM-BFGS method don't need the 1-D search, and that algorithm converge a 0.1~0.2 of Push-Off factor. But in this study, value of Push-Off factor is used 90, therefore 1-D search should be needed for effective convergency. That algorithm contains the "heuristic decision method". As a result of optimum design of 2-main steel girder birdge with 5${\times}$(1@50m), design methodology suggested in this study was demonstrated more economic and efficient than existing design and LCC optimization not considering bridge-rail longitudinal interaction and bridge-vehicle interaction.

Switching-Mode BJT Driver for Self-Oscillated Push-Pull Inverters

  • Borekci, Selim;Oncu, Selim
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.242-248
    • /
    • 2012
  • Self oscillating current fed push pull resonant inverters can be controlled without using special drivers. Dc current flows through the choke coil and the power switches, although the driving signals of the power switches are sinusoidal. When the base current is near zero, the transistors cannot be operated in switching mode. Hence higher switching power losses and instantaneous peak power during off transitions are observed. In this study, an alternative design has been proposed to overcome this problem. A prototype circuit has been built which provides dc bias current to the base of the transistors. Experimental results are compared with theoretical calculations to demonstrate the validity of the design. The proposed design decreases the peak and average power losses by about 8 times, when compared to conventional designs.

Soft Switching DC-DC Converter for AC Module Type PV Module Integrated Converter (AC 모듈형 태양광 모듈 집적형 컨버터를 위한 소프트 스위칭 DC-DC 컨버터)

  • Youn, Sun-Jae;Kim, Young-Ho;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.247-255
    • /
    • 2013
  • In this paper, a soft switching DC-DC converter for AC module type photovoltaic (PV) module integrated converter is proposed. A push-pull converter is suitable for a low voltage PV AC module system because the step-up ratio of a high frequency transformer is high and the number of primary side switches is relatively small. However, the conventional push-pull converters do not have high efficiency because of high switching losses by hard switching and transformer losses (copper and iron losses) by high turns-ratio of the transformer. In the proposed converter, primary side switches are turned on at zero voltage switching (ZCS) condition and turned off at zero current switching (ZVS) condition through parallel resonance between secondary leakage inductance of the transformer and a resonant capacitor. Therefore the proposed push-pull converter decreases the switching loss using soft switching of the primary switches. Also, the turns-ratio of the transformer can be reduced by half using a voltage-doubler of secondary side. The theoretical analysis of the proposed converter is verified by simulation and experimental results.

A Characteristic Analysis of Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and ZVS function (LCCC 공진회로와 ZVS 기능을 동시에 갖는 전류형 Push Pull DC-DC 컨버터의 특성해석)

  • An, Hang-Mock;Hwang, Gye-Ho;Lee, Dal-Hae;Nam, Seung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1324-1326
    • /
    • 2000
  • This paper proposes a Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and Zero Voltage Switching function to reduce turn on and off loss at the switching instants. This paper have the advantage which is able to operating safely in load short, because of DC reactor is connected with resonance reactor in order to supply a fixed current with low ripple from DC Power supply. The capacitor ($C_1$, $C_2$) connected in switch are common using as resonance capacitor and ZVS capacitor. The analysis of the proposed Current-Fed Push Pull type DC-DC converter is generally described by using normalized parameter, and we have evaluated characteristic values which is needed to design a circuit. We confirm a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

  • PDF

Computer modeling and analytical prediction of shear transfer in reinforced concrete structures

  • Kataoka, Marcela N.;El Debs, Ana Lucia H.C.;Araujo, Daniel de L.;Martins, Barbara G.
    • Computers and Concrete
    • /
    • v.26 no.2
    • /
    • pp.151-159
    • /
    • 2020
  • This paper presents an evaluation of shear transfer across cracks in reinforced concrete through finite element modelling (FEM) and analytical predictions. The aggregate interlock is one of the mechanisms responsible for the shear transfer between two slip surfaces of a crack; the others are the dowel action, when the reinforcement contributes resisting a parcel of shear displacement (reinforcement), and the uncracked concrete comprised by the shear resistance until the development of the first crack. The aim of this study deals with the development of a 3D numerical model, which describes the behavior of Z-type push-off specimen, in order to determine the properties of interface subjected to direct shear in terms cohesion and friction angle. The numerical model was validated based on experimental data and a parametric study was performed with the variation of the concrete strength. The numerical results were compared with analytical predictions and a new equation was proposed to predict the maximum shear stress in cracked concrete.

Effect of Intermittent Versus Continuous Infusion of Progesterone on LHRH Release In Viuo from the Rat Mediobasal Hypothalamus

  • 김경진
    • The Korean Journal of Zoology
    • /
    • v.32 no.4
    • /
    • pp.329-338
    • /
    • 1989
  • Present study examined the effect of intermittent versus continuous infusion of progesterone(P) on LHRH release in uiuo from the mediobasal hvpothalamus of ovariectomiEed, estradiol-primed adult rats bearing push-pull cannulae. Three experimental groups were studied: 1) control (perfusion medium only),2) intermittent perfusion of P (10-min on,20-min off, and 3) continuous perfusion of p. p (10 ng/mll was directly infused into the MBH following a 3 hr basal collection. Perfusates were collected at 10 min intents린s on ice and LHRH release was measured by LHRH radioimmunoassav. Cycle detector analysis revealed that the spontaneous HRH output in the control group was pulsatile over a 7 hr push-pull perfusion period. The mean basal LHRH release, pulse amplitude and pl서se period were 0.68 $\pm$ 0.03 ps110 min, 1.15 $\pm$0.08 pg and 60 $\pm$ 9 min, respectivelv. Intermi구eat perfusion of P clearly stimulated the mean LHRH release (pre-P vs post-P: 1.14 $\pm$ 0.18 vs 1.99 $\pm$ 0.53 pg) without changes in LHRH pulse frequency. In contrast to intermittent infusion of p, continuous administration of P faithed to modify LHRH release, since the mean LHRH release and pulse amplitude between pre-P and post-P perfusion urere similar. The in vitro study clearly showed that intermittent, but not continuous administration of P is effective in stimulating LHRH release. Therefore, it appears that rhythmic secretion of P mal be the erective signal for activating the neural LHRH apparatus.

  • PDF

A Design and Implementation of VOD Service System with Off-line Search Function (오프라인 검색기능을 가진 주문형 비디오 서비스 시스템 설계 및 구현)

  • 이혜정;박두순
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.3
    • /
    • pp.205-214
    • /
    • 2001
  • As the real time multimedia data service has become available due to the rapid progress of computer and Internet technology, the users can enjoy the newly developed service, which is called Video On-Dem-and(VOD). However, most of service providers have not paid their attention much on the software for various service modes on VOD, but they are only concentrating un the hardware to provide with the high resolution video display. Therefore, the service providers are recently to pay more attention on the software to cope with the various demands of users than hardware. So this paper has designed and implemented the VOD service system for those demands. Since the VOD service system suggested by this paper enable off-line search functions through E-mail, the users can possibly get the necessary information from off-line Search without connecting to the server while the current VOD service can prominently help users to save the time and effort to sea고 and select the Video contents by using periodical current awareness service supported by PUSH technology and user oriented information booking and feedback service supported by SDI service.

  • PDF

A 22kW Bidirectional Three-Phase Push-Pull Converter for Wide Voltage Range Application (넓은 입력 전압 범위를 갖는 20kW급 양방향 3상 푸쉬풀 컨버터)

  • Le, Tat-Thang;Jeong, Hyeonju;Kim, Seon-Ju;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.8-10
    • /
    • 2019
  • In this paper, a bidirectional three-phase push pull converter is analyzed for the high power, wide voltage range applications. From comparison analysis of two switching methods: PWM plus phase-shift (PPS) and dual-asymmetric PWM (DAPWM) with the effect of dead-time, the proposed hybrid control is aimed to reduce the circulating current under wide voltage range operation. Value of leakage inductance effect to the peak current value, current stress and conduction loss in facing the load variation. Trade-off between power range and slew rate of transformer current was analyzed for properly selecting value of the transformer leakage inductance. Experimental results from a 22-kW prototype are provided to validate the proposed concept.

  • PDF