• Title/Summary/Keyword: PTEE

Search Result 16, Processing Time 0.023 seconds

Surface energy change and hydrophilic formation of PE, PS and PTFE films modification by hydrogen ion assisted reaction

  • Jung Cho;Ki Hyun;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.202-202
    • /
    • 1999
  • The Polyethylene (PE), Polystyrene (PS) and Polytetrafluoroethylene (PTFE) surface modification was investigated by hydrogen io assisted reaction (H-IAR) in oxygen environment. The IAR is a kind of surface modification techniques using ion beam irradiation in reactive gas environment. The energy of hydrogen ion beam was fixed at 1keV, io dose was varied from 5$\times$1014 to 1$\times$1017 ions/$\textrm{cm}^2$, and amount of oxygen blowing gas was fixed 4ml/min. Wettability was measured by water contact angles measurement, and the surface functionality was analyzed by x-ray photoelectron spectroscopy. The contact angle of water on PE modified by argon ion beam only decrease from 95$^{\circ}$ to 52$^{\circ}$, and surface energy was not changed significantly. But, the contact angle using hydrogen ion beam with flowing 4ml/min oxygen stiffly decreased to 8$^{\circ}$ and surface energy to 65 ergs/cm. In case of PS, the contact angle and surface energy changes were similar results of PE, but the contact angle of PTEE samples decreased with ion dose up to 1$\times$1015 ions/$\textrm{cm}^2$, increased at higher dose, and finally increased to the extent that no wetting was appeared at 1$\times$1017 ions/$\textrm{cm}^2$. These results must be due to the hydrogen ion beam that cleans the surface removing the impurities on polymer surfaces, then hydrogen ion beam was activated with C-H bonding to make some functional groups in order to react with the oxygen gases. Finally, unstable polymer surface can be changed from hydrophobic to hydrophilic formation such as C-O and C=O that were confirmed by the XPS analysis, conclusionally, the ion assisted reaction is very effective tools to attach reactive ion species to form functional groups on C-C bond chains of PE, PS and PTFE.

  • PDF

Evaluation of Sampling and Analytical Methods for the Determination of Polycyclic Aromatic Hydrocarbons in the Ambient Atmosphere (환경대기중 다환방향족탄화수소의 포집과 분석방법에 관한 연구)

  • 백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.1-16
    • /
    • 1991
  • In this study, sampling and analytical procedures were evaluated for the determination of ambient levels of atmospheric PAH, both in gaseous and particulate phase. The method involves low-volume sampling and Soxhlet extraction of the filters and Tenax absorbent, followed by a clean-up stage using a silica column prior to analysis by reversed-phase HPLC with wavelength programmable fluorescence and UV detection. A total of 18 PAH were identified and quantified, all of which have been of environmental concern. In order to validate the methodology and to ensure compatibility of the results, the analytical method used for the determination of PAH was evaluated with respect to the efficiencies of extraction and clean-up procedure, HPLC separation, and lower limits of detection. In addition, substrate dependency of PAH recovery was investigated for the two types of fiters, i.e. glass fiber and PTFE filters.

  • PDF

A Clinical Comparision of Nonresorbable and Resorbable Membrane in the Treatment of Human Class II Furcation Defects (II급 치근이개부병변에서 비흡수성막과 흡수성막을 이용한 조직유도재생술의 임상적 비교)

  • Jang, Chae-Yun;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.689-711
    • /
    • 2001
  • The purpose of this study was to compare clinical results of guided tissue regeneration(GTR) using either a nonresorbable ePTFE membrane or a resorbable membrane made from a synthetic copolymer of glycolide and lactide(PLGA) in the treatment of human class Ⅱ furcation defects. The ePTEE membranes were applied to 16 patients with maxillary molar buccal class Ⅱ furcation defects as Group I, PLGA membranes were applied to 15 patients with maxillary molar buccal class Ⅱ furcation defects as Group Ⅱ, ePTFE membranes were applied to 20 patients with mandibular molar buccal class Ⅱ furcation defects as Group Ⅲ and PLGA membranes were applied to 20 patients with mandibular molar buccal class Ⅱ furcation defects as Group Ⅳ and bone graft materials(DFDBA) were applied in all groups. Probing depth, gingival recession, clinical attachment level, tooth mobility and sulcus bleeding index(SBI) were measured at baseline, 3, 6 and 12months postoperatively. In addition, membrane exposure levels were measured at surgery, 1, 2 and 6weeks postoperatively and postoperative complications were evaluated. The results were as follows: In all groups, there were statistically significant differences in probing depth reduction, gain of clinical attachment and mobility reduction at values of 3, 6 and 12months postoperatively compared to values of baseline, whereas no significant differences in SBI except Group I and gingival recession(p<0.05). Membrane exposure levels were increased at 1, 2 and 6weeks postopratively compared to value of baseline in Group I(p<0.05). There were no statistically significant differences between ePTFE and PLGA membrane in probing depth, clinical attachment level and SBI. There were minimal gingival recession and membrane exposure in Group Ⅳ and pain and swelling were the most common postoperative complications in Group Ⅱ, Ⅲ(p<0.05). In conclusion, this study showed that both nonresorbable membrane and resorbable membrane were effective similarly in the treatment of class Ⅱ furcation defects, without statistical differences in clinical measurements.

  • PDF

Systemic-Pulmonary Shunts Using Microporous Polytetrafluoroethylene Prosthesis [Early and Late Results] (Polytetrafluoroethylene 인조혈관을 이용한 체-폐동맥 단락술의 조기성적 및 원격 성적)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.50-57
    • /
    • 1986
  • Sixty-nine patients with various types of cyanotic congenital heart disease underwent systemic-pulmonary artery shunts with a microporous polytetrafluoroethylene [PTFE] prosthesis between 1979 and 1985. Their ages ranged from 2 months to 39 years [mean$\pm$SD: 5.2$\pm$7.4, median: 3.3 years]. Diagnosis included the following: Tetralogy of Fallot, 45: Double outlet right or left ventricle, 11: Single ventricle, .5: Transposition of great vessels, 4: Tricuspid atresia, 3 and Pulmonary atresia with intact ventricular septum, 1. Forty-eight patients had subclavian-pulmonary artery anastomosis, 12 patients aorta-right pulmonary artery anastomosis, 6 patients aorta-main pulmonary artery anastomosis, and 3 patients descending aorta-pulmonary artery anastomosis. The PTEE graft of 3 mm in diameter was used in 1, 4 mm in 29, 5 mm in 35 and 6 mm in 4 patients. Ten patients were died within 30 days after operation [mortality rate: 14.5%]. Among them, 6 patients were operated in urgency due to cardiac arrest or severe anoxic spell after cardiac catheterization, and so surgical mortality of elective operation is 9.5%. The 59 survivors showed improvement of the arterial oxygen saturation [65.4% - 9.8%] and hemoglobin [18.8 gm/dl - 16.0 gm/dl] values [V<0.01]. The follow up period ranged from 1 month to 67 months, [752 patient-months] and during this periods there were 4 late shunt failures after 3 months postoperatively with 4 mm graft, and 2 with 5 mm graft. The over-all patency rate of 4 mm PTFE was 85.9$\pm$9.2% [SEM] in 12 months and 40.9$\pm$22.5% in 24 months. The over-all patency rate of 5 mm PTFE was 87.5$\pm$9.6% in 12 months and 58.3$\pm$24.6% in 36 months. The lowest systolic pressure in death group was 64.9$\pm$15.0 mmHg and in survival group, 86.4$\pm$12.1 mmHg [P<0.001]. We think that the PTFE graft is useful in palliative shunt operation, but the effectiveness of the 4 mm PTFE graft may be limited. The blood pressure also may play an important role in patency of Prosthesis.

  • PDF

Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD (TLD를 이용한 X-선 수중 흡수선량 측정 및 해석)

  • Oh, Jang-Jin;Jun, Jae-Shik;Hah, Suck-Ho;Kim, Wuon-Shik;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.21-28
    • /
    • 1988
  • Absorbed dose in water was analyzed by Burlin's general cavity theory for medium X-ray energy region (HVL : 0.29, 0.84, 1.60, 2.62mm Cu) using LiF : PTFE TL dosimeter(0.4 mm ${\times}\;{\phi}$ 12.5mm, hot-pressed LiF TLD-700) which was enclosed in lucite capsule. The absorbed dose rate at 5cm depth in water phantom was determined with measurement error of ${\pm}5%$. This result was compared to that of the ionization method, indirectly absolute measurement method, of which measurement error of ${\pm}2%$. The difference between these two results lies within measurement error of LiF : PTFE method. Therefore, the absorbed dose in water obtained by LiF: PTFE is reliable, and this result suggests the base to estimate dose-equivalent for medium X-rays.

  • PDF

Midterm Results of Mitral Valve Repair by the New Chordae Formation Technique (승모판막 폐쇄부전증에서 신건삭 형성술을 이용한 판막 성형술의 임상분석)

  • Lee, Jae-Won;Lim, Han-Jung;Jung, Sung-Ho;Kim, Kun-Il;Choo, Suk-Jung;Song, Hyun;Song, Meung-Gun
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.329-337
    • /
    • 2001
  • 배경: 승포판 전엽이나 교련 또는 여러 판엽에 걸쳐 광범위한 병변으로 인한 승모판 역류의 경우 수술수기에 대한 뚜렷한 정립이 되어 있지 않은 실정이다. 최근 이러한 병변의 승모판 역류의 경우 PTEE(Polytetrafluro-ethylene)을 이용한 신건삭 형성술의 시행이 점차 늘고 있다. 이에 저자들은 PTEE를 이용한 신건삭 형성술이 승모판 성형술에 어떠한 영향을 미치는지 알아보고자 하였다. 대상 및 방법: 1994년 1월부터 1999년 12월까지 승모판막 성형술을 시행 받은 322명의 환자 중에서 신건삭 형성술을 이용하여 승모판 성형술을 시행한 144례(I군)과 신건삭 형성술 이외의 방법으로 승모판 성형술을 시행한 178례(II군)를 대상으로 하였다. 두 군에서 수술 직후ㅘ 수술 후 6개월, 1년 및 1년 단위로 주기적인 심초음파를 시행하였고 이를 통계적 검정하였다. 결과: 같은 기간 승모판 성형술은 승모판막 폐쇄 부전증으로 내원한 환자의 95%(306)에서 추적 관찰이 가능하였다. 두 구난에 수술 전 혈류 역학적인 차이를 보이지 않았고, 수술 전 평균 승모판막 폐쇄 부전의 정도는 I군이 3.8$\pm$0.4, II군이 3.6$\pm$0.3였으나 수술 후 추적 관찰에서 각각 1.3$\pm$0.9와 1.1$\pm$0.7 정도의 양호한 판막 성형술의 결과를 보였고 승모판막 면적의변화나 승모판막에서의 평균 압력차이 등 혈류 역학적인 결과에도 차이를 보이고 있지 않았다. 술 후 3명(0.9%)의 조기 사망과 4명 (1.2%)의 후기 사망이 있었으나 두 군간의 차이는 보이지 않았다. 만기 생존율( 93.7$\pm$3.3 vs 88.0$\pm$1.95) 및 판막살패가 발생하기 않을 확률( 93.7$\pm$3.6 vs 93.3$\pm$3.4%) 과 재수술이 필요치 않을 활률(99.3$\pm$0.7 vs 96.0$\pm$1.9%), 색전증, 감염성 심내막염, 판막과 관련된 합병증 발생률 등에서 두 군간에 의미 있는 차이는 없었다. 전엽과 후엽에서 신건삭 형성술을 시행한 환자에서는 통계학적인 차이가 없었다(p=0.29) 결론: 신건삭 형성술을 이용한 승모판 성형술은 승모판 성형술의 증가(r=0.98, p<0.01)를 가져 왔을 뿐만 아니라 내구성과 안정성에 있어 기존의 안전화된 수술 수기와 견줄만하다. 특히 이러한 신건삭 형성술은 승모판 전엽에 병변이 있는 경우와 교련부 및 여러 엽에 광범위한 병변으로 인하여 재건술이 어려운 경우에도 승모판 재건을 가능하게 하는 우수한 수술 수리가 사료된다.

  • PDF