검색결과 36건 처리시간 0.028초

궤도민감도 분석에 기반하여 복입력 전력시스템 안정화 장치(Dual-Input PSS)의 비선형 파라미터 최적화 기법 (Optimal Tuning of Nonlinear Parameters of a Dual-Input Power System Stabilizer Based on Analysis of Trajectory Sensitivities)

  • 백승묵;박정욱
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.915-923
    • /
    • 2008
  • This paper focuses on optimal tuning of nonlinear parameters of a dual-input power system stabilizer(dual-input PSS), which can improve the system damping performance immediately following a large disturbance. Until recently, various PSS models have developed to bring stability and reliability to power systems, and some of these models are used in industry applications. However, due to non-smooth nonlinearities from the interaction between linear parameters(gains and time constants of linear controllers) and nonlinear parameters(saturation output limits), the output limit parameters cannot be determined by the conventional tuning methods based on linear analysis. Only ad hoc tuning procedures('trial and error' approach) have been used. Therefore, the steepest descent method is applied to implement the optimal tuning of the nonlinear parameters of the dual-input PSS. The gradient required in this optimization technique can be computed from trajectory sensitivities in hybrid system modeling with the differential-algebraic-impulsive-switched(DAIS) structure. The optimal output limits of the dual-input PSS are evaluated by time-domain simulation in both a single machine infinite bus(SMIB) system and a multi-machine power system in comparison with those of a single-input PSS.

GIS와 VE, LCC 개념에 의한 동적 상수도관망 대안 결정 (Capacity Expansion Modeling of Water-distribution Network using GIS, VE, and LCC)

  • Kim, Hyeng-Bok
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 1999년도 추계학술대회 발표요약문
    • /
    • pp.21-25
    • /
    • 1999
  • Planning support systems(PSS) add more advanced spatial analysis functions than Geographic information systems(GIS) and intertemporal functions to the functions of spatial decision support systems(SDSS). This paper reports the continuing development of a PSS providing a framework that facilitates urban planners and civil engineers in conducting coherent deliberations about planning, design and operation & maintenance(O&M) of water-distribution networks for urban growth management. The PSS using dynamic optimization model, modeling-to-generate-alternatives, value engineering(VE) and life-cycle cost(LCC) can generate network alternatives in consideration of initial cost and O&H cost. Users can define alternatives by the direct manipulation of networks or by the manipulation of parameters in the models. The water-distribution network analysis model evaluates the performance of the user-defined alternatives. The PSS can be extended to include the functions of generating sewer network alternatives, combining water-distribution and sewer networks, eventually the function of planning, design and O&H of housing sites. Capacity expansion by the dynamic water-distribution network optimization model using MINLP includes three advantages over capacity expansion using optimal control theory(Kim and Hopkins 1996): 1) finds expansion alternatives including future capacity expansion times, sizes, locations, and pipe types of a water-distribution network provided, 2) has the capabilities to do the capacity expansion of each link spatially and intertemporally, and 3) requires less interaction between models. The modeling using MINLP is limited in addressing the relationship between cost, price, and demand, which the optimal control approach can consider. Strictly speaking, the construction and O&M costs of water-distribution networks influence the price charged for the served water, which in turn influence the. This limitation can be justified in rather small area because price per unit water in the area must be same as that of neighboring area, i.e., the price is determined administratively. Planners and engineers can put emphasis on capacity expansion without consideration of the relationship between cost, price, and demand.

  • PDF

복합화력발전소 가스터빈 발전기계통 모델정수 도출 및 검증을 위한 특성시험 (Characteristic Tests on the Gas Turbine Generator System for Determination and Verification of Model Parameters in a Combined Cycle Power Plant)

  • 김종구;유호선
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.35-40
    • /
    • 2021
  • 본 연구에서는 서인천복합 6호기 가스터빈 발전기계통에 대하여 기술특성시험을 실시하여 모델정수를 도출하고 검증하였다. 발전기 최대/최소 무효전력 한계시험 결과 최대 무효전력 한계는 80 MVar이고, 최소 무효전력 한계는 -30 MVar이다. 발전기는 GENROU 모델을 사용하였고, 계자시정수(T'do)는 4.077 s, 관성정수(H)는 5.461 P.U로 결정하였다. 여자시스템은 ESST4B 모델을 사용, 무부하 2% AVR 스텝시험을 모의하는 방식으로 모델정수를 도출하고 검증하였으며, PSS 모델링은 PSS2A 모델정수로 도출하였고, PSS Off/On일때 측정된 계측 데이터를 모의, 비교하여 검증하였다. 조속기-터빈는 GGOV1 모델을 사용하여 모델정수를 도출하고 검증하였다. PSS/E 시뮬레이션 프로그램을 통해 10% 조속기 스텝시험을 모의하여 결정된 조속기-터빈 모델정수의 수치 안정성을 확인하였다.

실효치 기반 동적 모의를 위한 HVDC UDM 모델 개발 (Development of HVDC user defined model for RMS-based dynamic simulation)

  • 곽청래;탕도안투;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.318-319
    • /
    • 2011
  • This paper presents a new user defined modeling about HVDC system based on the PSS/E. The principles, methods and procedures of user defined modeling for dynamic simulation are expounded. Comparing beween the dynamic simulations results of a power system by CDC4T in the PSS/E library and a user defined model CDCKU1 respectively, we illustrate the general usage of custom features and verify the model accuracy. Future work about CDCKU series and practical models will be considered to enhance the power system stability in Korea.

  • PDF

계통전압 및 보상용 조상설비 적용 검토시 S.C 모델링 최적화 방안 연구 (A Study of Modeling Optimization Scheme for application of Power System Voltage & Compensating Phase Modifying Equipment)

  • 윤기섭;백승도;김주성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.192-194
    • /
    • 2004
  • At present, application of PSS/E input data for power flow , stability and fault analysis consist of only 154kV and over data(except 22.9kV data). 22.9kV(5.C) Static Condenser is in operation and installation at 22.9kV Bus of 154kV Substation. however, we assume that 22.9kV 5.C install at 154kV Bus. so, we need to study and search about critical limit for 154kV Bus standard operating Voltage according to 22.9kV 5.C Modeling Site by PSS/E Ver28

  • PDF

PSS/E를 이용한 UPFC모델링 (UPFC modeling using the PSS/E)

  • 유일도;김준모;한영성;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.294-296
    • /
    • 2001
  • PSS/E offers a power flow model of UPFC in the new version. The Dynamic model was developed in a form of user-define model that is a external function, Now is a stage of verification through variety examples. Importance of this model is in the point which it is necessary for the simulation on the stability. This paper presents the Dynamic model that is defined by user. First. the theory will be discussed, and then for verification on right operation, resultes of application to KEPRI network will be showed.

  • PDF

PSS/E - Matlab Simulink/SimPower 간 순시치 시뮬레이션 비교에 관한 연구 (Study on comparisons between PSS/E and Matlab Simulink/SimPower Result on network system data)

  • 유연태;김기석;이창근;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.249-250
    • /
    • 2015
  • Technological advance of power elcetronic devices using semiconductor switches in last several decades, invoke the increase of switching devices' penetration in the system like STATCOM or HVDC and also, increase the difficulty to adjust switching characteristics in the virtual simulating configuration, which are not capable of reflect the detailed phenomena. To investigate harmful effect of switching devices into the grid, detailed modeling of power electronic devices are necessary, and the first step for entire grid modelling is simulate power system in time domain model. In this paper, simple two bus system with synchronous generator and infinite bus on the other side has been compromised in two simulation environment, using PSS/E and Matlab/Simulink. Comparing the result of two simulation result will give answers to the fundamental difference between two type of simulation environment.

  • PDF

상사지원인식이 역할내 성과와 역할외 성과에 미치는 영향: 직무기반 심리적 주인의식의 매개효과를 중심으로 (Effect of Perceived Supervisor Support on In-Role and Extra-Role Performance: The Mediating Role of Job-Based Psychological Ownership)

  • 차동옥;홍권표;장제욱;박성현;강금원
    • 한국콘텐츠학회논문지
    • /
    • 제12권2호
    • /
    • pp.398-410
    • /
    • 2012
  • 본 연구는 상사지원인식이 조직구성원들의 역할내 성과와 역할외 성과에 미치는 영향을 직무기반 심리적 주인의식의 매개효과를 중심으로 규명하는데 목적이 있다. 일반기업 종사자 269명으로부터 설문을 받고, 회귀분석과 구조방정식모형을 사용하였다. 선행연구에 의하면, 상사지원인식과 직무성과 간에 정(+)적인 관계가 있다는 것을 확인하였다. 그러나 아직까지는 상사지원인식과 성과 간의 관계에 있어서 직무기반 심리적 주인의식의 매개효과를 실증적으로 분석한 연구가 거의 없었다. 따라서 본 연구는 역할내 성과와 역할외 성과를 예측하는데 있어서 매개효과를 분석하였다. 본 연구에 의하면, 직무기반 심리적 주인의식이 상사지원인식과 역할내 성과 간의 관계에 있어서 완전매개를 하고, 상사지원인식과 역할외 성과 간의 관계에서 부분매개를 하는 것으로 나타났다. 그리고 향후연구와 실무적인 시사점에 대해서 논의하였다.

양수발전소의 모델링에 관한 연구 (A Study on Modeling of Pumped Storage Power Plant)

  • 한윤교;이승윤;박철원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.77-78
    • /
    • 2015
  • For the smooth operation and efficient management of pumped storage power plants, we should be understand a generator, turbine, exciter, governor, and stabilizer and prepare an abnormal accident through an accident simulation by software such as PSCAD, PSS/E. This paper investigates configuration of the generator system of ${\bigcirc}{\bigcirc}$ pumped storage power plant. And describes the modeling and fault simulation studies using PSCAD.

  • PDF

IPLAN을 이용한 ULTC와 전압안정도 해석 (ULTC and Voltage Stability Analysis with use of IPLAN)

  • 홍영환;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.223-226
    • /
    • 2004
  • This paper describers the power demand and the voltage stability in power system. Especially the power demand on summer is more and more increase in korea. According to load quantity is increasing voltage is getting down. And power system becomes unstable. So this paper is prevent voltage down using to ULTC modeling which is a part in a transformer. Therefore our purpose is power system stability increasing as variable state like a load increasing or a fault. Then this paper is using IPLAN and PSS/E as analysis tool. PSS/E is very powerful engine on load flow analysis. And IPLAN is capable of using on variable program compiling with user.

  • PDF