• Title/Summary/Keyword: PSS/E Simulation

Search Result 76, Processing Time 0.034 seconds

Development & Application of Generator Control System Models of EUROSTAG for Stability Study of Power Systems (전력계통의 안정도 해석용 발전기제어계의 EUROSTAG 모형 개발 및 적용)

  • 김학만;오태규
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.109-117
    • /
    • 2003
  • Because of the difficulty of acquiring new generation sites and right-of-way, additional units have been added to the existing generation sites and the transmission system has been developed into highly meshed configuration. This structural characteristics may cause restriction on the reliable operation of power systems. In other to meet with this problem, the enhancement of system analysis techniques and establishment of appropriate measures have been required in this situation. In addition the deregulation of electric power industry in Korea would require better tools for power system analysis and control. In this paper, exciter system models, speed governor system models and PSS models of EUROSTAG for stability study are developed. Comparison with simulation results of PSS/E is performed for verification of EUROSTAG models.

InTouch HMI Development to Real-Time Power System Analysis (실시간 전력 계통 해석을 위한 InTouch HMI 구현)

  • Ahn, Chang-Han;Lee, Sang-Deok;Park, Ji-Ho;Chang, Byung-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2322-2327
    • /
    • 2009
  • Uncertainty of power system operation increases due to complexity and facilities diversification in the power system. Therefore the importance of SCADA(Supervisory Control and Data Acquisition) system which obtain and manage the actual data in real-time is very important. Accordingly in the studies of power system analysis, the efforts to include real-time power system analysis in simulation and applications are made in many ways. The real-time communication characteristics of SCADA system is considered so as to develop the power system analysis program that matches actual system conditions. The observation and management of SCADA system is realized by Intouch which is mainly used for factory automation and PSS/E(Power System Simulator for Engineers) provides real time system data. SQL DB and Python language is used for real-time communication between the softwares. It is very comfortable to use the various functions in Intouch WindowMaker.

A Study on Modeling of Pumped Storage Power Plant (양수발전소의 모델링에 관한 연구)

  • Han, Yoon-Gyo;Lee, Seung-Yoon;Park, Chul-Won
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.77-78
    • /
    • 2015
  • For the smooth operation and efficient management of pumped storage power plants, we should be understand a generator, turbine, exciter, governor, and stabilizer and prepare an abnormal accident through an accident simulation by software such as PSCAD, PSS/E. This paper investigates configuration of the generator system of ${\bigcirc}{\bigcirc}$ pumped storage power plant. And describes the modeling and fault simulation studies using PSCAD.

  • PDF

Cell ID Detection Schemes Using PSS/SSS for 5G NR System (5G NR 시스템에서 PSS/SSS를 이용한 Cell ID 검출 방법)

  • Ahn, Haesung;Kim, Hyeongseok;Cha, Eunyoung;Kim, Jeongchang
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.870-881
    • /
    • 2020
  • This paper presents cell ID (cell identity) detection schemes using PSS/SSS (primary synchronization signal/secondary synchronization signal) for 5G NR (new radio) system and evaluates the detection performance. In this paper, we consider two cell ID detection schemes, i.e. two-stage detection and joint detection schemes. The two-stage detection scheme consists of two stages which estimate a channel gain between a transmitter and receiver and detect the PSS and SSS sequences. The joint detection scheme jointly detects the PSS and SSS sequences. In addition, this paper presents coherent and non-coherent combining schemes. The coherent scheme calculates the correlation value for the total length of the given PSS and SSS sequences, and the non-coherent combining scheme calculates the correlation within each group by dividing the total length of the sequence into several groups and then combines them non-coherently. For the detection schemes considered in this paper, the detection error rates of PSS, SSS and overall cell ID are evaluated and compared through computer simulations. The simulation results show that the joint detection scheme outperforms the two-stage detection scheme for both coherent and non-coherent combining schemes, but the two-stage detection scheme can greatly reduce the computational complexity compared to the joint detection scheme. In addition, the non-coherent combining detection scheme shows better performance under the additive white Gaussian noise (AWGN), fixed, and mobile environments.

A Comparative Study on the Effect of STATCOM and UPFC in the Static Analysis of Power Systems (전력계통의 정태해석에 미치는 STATCOM과 UPFC의 영향에 대한 비교 연구)

  • Kim, Deok-Young;Lee, Ji-Yeol;Kook, Kyung-Soo;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.214-216
    • /
    • 2000
  • This paper presents an comparative study on the effect of STATCOM and UPFC to the power system static analysis. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for static analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF

Transient Stability Analysis using Large-Scale Real Time Digital Simulator

  • Yoon, Yong-Beum;Kim, Tae-Kyun;Won, Jong-Ryul;Shin, Jeong-Hoon;Kim, Yong-Hak;Cha, Seung-Tae;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.33-38
    • /
    • 2001
  • The KEPS(KEPCO's Enhanced Power system Simulator) Real Time Digital Simulator(RTDS) is the largest real time power system simulator ever built. A power system which includes 320 (3-phase) buses and 90 generators has been modeled and run in real time. Since such large-scale systems were involved, it was not practical to validate them using non-real time electro-magnetic transient programs such as EMTDC™ or EMTP. Instead, the results of the real time electromagnetic transient simulation were validated by comparing to transient stability simulations run using PTI's PSS/E™ program. The comparison of results from the two programs is very good in almost all cases. However, as expected, some differences did exist and were investigated. The differences in the results were primarily traced to the fact that the electromagnetic transient solution algorithm provides more detail solutions and therefore greater accuracy than the transient stability algorithm. After finding very good comparison of results between RTDS Simulator and PSS/E, and after investigating the discrepancies found, KEPCO gained the necessary confidence to use the large-scale real time simulator to analyze and develop their power system.

  • PDF

Coordination of UPFC and Reactive Power Sources for Steady-state Voltage Control (정상상태 전압제어를 위한 UPFC와 조상설비의 협조)

  • Park, Ji-Ho;Lee, Sang-Duk;Jyung, Tae-Young;Jeong, Ki-Seok;Baek, Young-Sik;Seo, Gyu-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.921-928
    • /
    • 2011
  • This paper presents a new method of local voltage control to achieve coordinative control among UPFC(Unified Power Flow Controller) and conventional reactive compensation equipments, such as switched-shunt and ULTC(Under-Load Tap Changing) transformer. Reactive power control has various difficult aspects to control because of difficulty of system analysis. Recently, the progress of power electronics technologies has lead to commercial availability of several FACTS(Flexible AC Transmission System) devices. The UPFC(Unified Power Flow Controller) simultaneously allows the independent control of active and reactive power flows as well as control of the voltage profile. When conventional reactive power sources and UPFC are used to control system voltage, the UPFC reacts to the voltage deviation faster than the conventional reactive power sources. Keeping reactive power reserve in an UPFC during steady-state operation is always needed to provide reactive power requirements during emergencies. Therefore, coordination control among UPFC and conventional reactive power sources is needed. This paper describe the method to keep or control the voltage of power system of local area and to manege reactive power reserve using PSS/E with Python. The result of simulation shows that the proposed method can control the local bus voltage within the given voltage limit and manege reactive power reserve.

Development of the Power Restoration Training Simulator for Jeju Network

  • Lee, Heung-Jae;Park, Seong-Min;Lee, Kyeong-Seob;Song, In-Jun;Lee, Nam-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.18-23
    • /
    • 2006
  • This paper presents an operator training simulator for power system restoration against massive blackout. The system is designed especially focused on the generality and convenient setting up for initial condition of simulation. The former is accomplished by using power flow calculation methodology, and PSS/E data is used to set up the initial state for easy setting. The proposed simulator consists of three major components-a power flow(PF), a data conversion(CONV), and, a GUI module. The PF module calculates power flow, and then checks over-voltages of buses and overloads of lines. The CONV module composes a Y-Bus array and a database at each restoration action. The initial Y-Bus array is composed from PSS/E data. A user friendly GUI module is developed including a graphic editor and a built-in operation manual. The maximum processing time for one step operation is 15 seconds, which is adequate for training purpose.

A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System (HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구)

  • Kim Chan-Ki;Han Byoung-Sung;Park Jong-Kwang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.457-467
    • /
    • 2005
  • This paper deals with the new frequency controller of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency controller after the removing of the present synchronous compensators. The simulation methods are the mix of PSCAD/EMTDC and PSS/E, the main system studies are done for the transient state analysis using PSCAD/EMTDC. The study cases are completed involving 3 phase, single phase trip and load tripping events and study plots presented. In conclusion, the new frequency measurement from the AC network gives effective frequency control and dynamic performance.

Dynamic Characteristic Analysis of Water-Turbine Generator Control System of Sihwa Tidal Power Plant (시화조력발전소 수차발전기 제어시스템의 동적 특성 해석)

  • Ahn, Sang-Ji;Ban, Yu-Hyeon;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.180-185
    • /
    • 2012
  • Tidal power is one of new and renewable energy sources. The seawater is stored inside a tidal embankment built at the mouth of a river or bay, where tides ebb and flow. The water turbine-generators produce power by exploiting the gap in the water level between the water outside and inside the embankment. Tidal power plant is a large plant that is installed on the sea. And then, the facility's operations and a separate control system for monitoring and maintenance is required. However, this plant predictive control of building systems and technologies have been avoided the transfer of technology from advanced global companies. Accordingly, the control system for core technology development and localization is urgently needed. This paper presents modeling and simulation using by PSS/E about generator, governor, exciter, and power system stabilizer for control system in Sihwa tidal power plant to improve the efficiency and develope of core technology. And the dynamic characteristics of governor and exciter were analyzed.