• Title/Summary/Keyword: PRO II Simulation

Search Result 46, Processing Time 0.023 seconds

Cryogenic Distillation Simulation for Hydrogen Isotopes Separation (수소 동위원소 분리를 위한 초저온증류공정 모사)

  • Noh, Sanggyun;Rho, Jaehyun;Cho, Jungho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4643-4651
    • /
    • 2013
  • In this study, we have surveyed the new technologies in the cryogenic distillation of ITER, equilibrium reactors and helium refrigeration cycle contained in the isotope separation system (ISS). We also have collected thermodynamic and transport properties for $H_2$, HD, $D_2$, HT, DT and $T_2$ components of which properties are not built in a general purpose chemical process simulators such as Aspen Plus and PRO/II with PROVISION. Verification works have been performed to compare between literature data and simulation results. For the simulation of ISS involving six hydrogen isotope components, four distillation columns and two equilibrium reactors are used for the separation of $D_2$ and DT from $T_2$.

A Study of Simulation on the Refrigerated Warehouse System Based on the Cold Energy of Lng Using the Pro-Ii Simulator (LNG 냉열을 이용한 냉장·냉동 창고 모사에 관한 연구)

  • HAN, DANBEE;KIM, YOONJI;YEOM, KYUIN;SHIN, JAERIN;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.401-406
    • /
    • 2017
  • When Liquified Natural Gas (LNG) is vaporized into NG for industrial and household usage, tremendous cold energy was transferred from LNG to seawater during phase-changing process. This heat exchanger loop is not only a waste of huge cold energy, but will cause thermal pollution to the coastal fishery area also when cold water was re-injected into the sea. In this study, an innovation design has been performed to reclaim the cold energy for -35 to $62^{\circ}C$ refrigerated warehouse. Conventionally, this was done by installing mechanical refrigeration systems, necessitating tremendous electrical power to drive temperature. A closed loop LNG heat exchangers in series was designed to replace the mechanical or vapor-compression refrigeration cycle by process simulator. The process simulation software of PRO II with provision has been used to simulate this process for various conditions, what to effect on cold energy and used energy for re-liquefaction and evaporation process. In addition, through analysis the effect of the change of LNG supply pressure on sensible and latent heat, optimum operational conditions was suggested for LNG cold energy warehouse.

Simulation and Optimization Study on the Pressure Swing Distillation of Methyl ethyl ketone-Water System (Methyl ethyl ketone과 물 이성분계 혼합물의 압력변환 증류공정에 대한 전산모사 및 최적화에 대한 연구)

  • Noh, Sang-Gyun;Rho, Jae-Hyun;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3764-3773
    • /
    • 2012
  • In this study, modeling and optimization works were completed for the separation of 99.9 mol% of methyl ethyl ketone from water through a pressure-swing distillation process since the azeotropic composition varies very sensitively with the change of system pressure. PRO/II with PROVISION release 9.1 was used for the computer simulation and Wilson activity coefficient model was chosen as a modeling equation. A pressure-swing distillation process can be classified into a low-high pressure columns configuration and a high-low pressure columns configuration. In this work, each configurations were optimized for the minimization of steam consumptions, respectively and were compared.

A Comparative Study Between One- and Two-Stage Refrigeration System for the Natural Gas Cooling Process (천연가스 냉각을 위한 1단 냉동과 2단 냉동 사이의 비교연구)

  • Cho, Jung-Ho;Kim, Dong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.3106-3111
    • /
    • 2010
  • In this study, a comparative study was performed between one- and two-stage refrigeration system to cool the natural gas temperature down to $-40^{\circ}C$ using propane as a chilling medium. As a thermodynamic model, Peng-Robinson equation of state equation was applied and PRO/II with PROVISION release 8.3 at Invensys company was utilized for the simulation of the refrigeration system. Through this study, optimization work showed that two-stage refrigeration system was proven to save about 33.5% refrigeration power consumption compared to the one-stage refrigeration cycle.

A Study on the Optimization of Process for Ethanol Dehydration Azeotropic Distillation (에탄올 탈수 공비 증류공정 최적화에 대한 연구)

  • Cho, Jungho;Jeon, Jongki
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.474-481
    • /
    • 2005
  • In this study, modeling and optimization work were performed to obtain nearly pure anhydrous ethanol from aqueous ethanol mixtures using benzene as an entrainer. NRTL liquid activity coefficient model was adopted for phase equilibrium calculations and PRO/II with PROVISION 6.01, a commercial process simulator, was used to simulate the azeotropic distillation process. We used the total reboiler heat duties as an objective function and the concentration of ethanol at concentrator top as a manipulated variable. As a result, 76 mole percent of ethanol at concentrator top gave an optimum value which minimized the total reboiler heat duties of three distillation columns.

A Simulation Study on the Cascade Refrigeration Cycle for the Liquefaction of Natural Gas [1] (천연가스 액화를 위한 캐스케이드 냉동사이클의 전산모사에 대한 연구 [1])

  • Kim, So-Hee;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.552-558
    • /
    • 2011
  • In this paper, simulation works for a cascade refrigeration cycle using propane, ethylene and methane as a refrigerant have been performed for the liquefaction of natural gas using Peng-Robinson equation of state built-in PRO/II with PROVISION release 8.3. The natural gas feed compositions were supplied from Korea Gas Corporation and the flow rate was assumed to be 5.0 million tons per annual. Supply temperature for propane refrigerant was fixed as $-40^{\circ}C$, that for ethylene refrigerant as $-95^{\circ}C$, and that for methane refrigerant as $-155^{\circ}C$. Natural gas was finally cooled and liquefied to $-162^{\circ}C$ by Joule-Thomson expansion. Conclusively, 91.64% by mole of the natural gas liquefaction ratio was obtained through a cascade refrigeration cycle and Joule-Thomson expansion.

The Effect of DME on Phase Equilibria of Methane Hydrates (DME가 메탄하이드레이트 상평형에 미치는 영향)

  • Lim, Gyegyu;Lee, Gwanghee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.660-669
    • /
    • 2012
  • Gas resources captured in the form of gas hydrates are an order of magnitude larger than the resources available from conventional resources. Focus of this research is to investigate the effect of DME on phase equilibria of methane hydrate, as well as the possibility of the use of the PRO/II computer simulation to estimate the phase equilibria. In systems containing water and a gaseous component like, for instance, methane, ethane, and propane, gas hydrates may occur, if conditions in terms of pressure and temperature are satisfied. Mixtures of gases, e.g. LPG or natural gas, are also able to form gas hydrates in the presence of water. The experiments presented here were performed at temperatures varying between 268.15K and 288.15K and at pressures varying between 1.88 MPa and 10.56 MPa. It was found that the phase equilibria of methane hydrate is influenced by the addition of DME to the system. The pressure for the equilibrium hydrate-liquid water-vapor (H - $L_w$ - V) in the system water + methane is reduced upon addition of DME. The phase equilibria of methane hydrate can be estimated by the PRO/II computer simulation, whereas those of methane hydrate containing DME or LPG can't be estimated properly.

A Study on the Power Saving with the Use of LNG Cold Heat in a Cascade Refrigeration Cycle using Methane, Ethylene and Propylene as Refrigerants (메탄, 에틸렌 및 프로판 냉매를 활용한 다원 냉동 사이클에서 LNG 냉열을 활용한 동력 절감 방안에 대한 연구)

  • CHO, JUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.3
    • /
    • pp.302-306
    • /
    • 2020
  • In this study, computer simulation works using PRO/II with PROVISION V10.2 have been performed for a cascade refrigeration cycle using methane, ethylene and propane as refrigerants. LNG cold heat was also utilized in order to save the compression powers for the ethylene and propane refrigeration cycles. It was concluded that about 77% of compression power can be saved by using LNG cold heat through the exchanging heat with refrigerants. We could also know that the cold heat price contained in 1 ton of LNG is 16,155 won.

Estimation of the Ammonia Refrigeration Cycle Using LNG Cold Heat (액화천연가스 냉열을 활용한 암모니아 냉동 사이클의 추산)

  • NOH, SANGGYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.357-362
    • /
    • 2018
  • In this study, computer simulation and optimization works have been performed for a refrigeration cycle using ammonia as a refrigerant and also how much power was saved when the liquefied natural gas cold heat is replaced for the refrigeration cycle. PRO/II with PROVISION release 10.0 from Schneider electric company was used, and Peng-Robinson equation of the state model was selected for the modeling of the refrigeration cycle and LNG cold heat utilization process.

Energy Consumption of Biodiesel Production Process by Supercritical and Immobilized Lipase Method (초임계와 Lipase 고정화에 의한 바이오디젤 생산 공정의 에너지소비량)

  • Min, Eung-Jae;Lee, Euy-Soo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.257-263
    • /
    • 2012
  • Biodiesel is a renewable energy which is nontoxic and acting as a replacement for conventional diesel which derived from fossil fuel. Classified biodiesel producing way such as acid, base, supercritical and enzyme methods, this study focused on eco-friendly production of biodiesel using supercritical and immobilized enzyme process. Assuming a plant with a production rate of 10,000 tons a year, a PRO II simulator program was used to simulate the product conversion rate and total energy consumption. The product conversion in supercritical process and immobilized enzyme was found to be 91.17% (including 0.9% glycerol) and 93.18% (including 1.0% glycerol) respectively. The result shows that the efficiency of immobilized enzyme process is higher compared to supercritical process but having lower end product purity. From the energy consumption point of view, supercritical process consume about 8.9 MW while immobilized enzyme process consume much lower energy which is 3.9 MW. Consequently, this study certifies that energy consumption of supercritical process is 2.3 times higher than immobilized enzyme process.