• 제목/요약/키워드: PR-controller

검색결과 66건 처리시간 0.026초

PID 제어기를 이용한 도립진자 제어 (The Control of Inverted Pendulum for PID Controller)

  • 송해석;장갑부;노태정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.124-124
    • /
    • 2000
  • In this paper, The PID controller for stabilization of an inverted pendulum system is proposed. The PR control rule is very common in control systems. It is the basic tool for solving most process control problem. We consider the inverted pendulum system containing two PID controllers. The first controls the angle of the pendulum. The second is used to control the position of the cart. We can show stabilization of the PID controller through simulation of the inverted pendulum system.

  • PDF

Active Damping of LLCL Filters Using PR Control for Grid-Connected Three-Level T-Type Converters

  • Alemi, Payam;Jeong, Seon-Yeong;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.786-795
    • /
    • 2015
  • In this paper, an active damping control scheme for LLCL filters based on the PR (proportional-resonant) regulator is proposed for grid-connected three-level T-type PWM converter systems. The PR controller gives an infinite gain at the resonance frequency. As a result, the oscillation can be suppressed at that frequency. In order to improve the stability of the system in the case of grid impedance variations, online grid impedance estimation is applied. Simulation and experimental results have verified the effectiveness of the proposed scheme for three-phase T-type AC/DC PWM converters.

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.469-478
    • /
    • 2013
  • This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

단상 UPS 제어기 설계 및 개발 (Development and design of single-phase uninterruptible power supply)

  • 김형섭;유은식;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.203-204
    • /
    • 2014
  • In this paper, single-phase uninterruptible power supply design method is presented. In this control scheme, input current, output current and output voltage are used. For voltage control PR controller is used and that for current controller is PI controller. The gains for controllers are sought by the classical method for determining gains. Throughout simulations the performance of single-phase UPS is verified.

  • PDF

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

A New Control Strategy for a Three-Phase PWM Current-Source Rectifier in the Stationary Frame

  • Guo, Qiang;Liu, Heping;Zhang, Yi
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.994-1005
    • /
    • 2015
  • This paper presents a novel power control strategy for PWM current-source rectifiers (CSRs) in the stationary frame based on the instantaneous power theory. In the proposed control strategy, a virtual resistance based on the capacitor voltage feedback is used to realize the active damping. In addition, the proportional resonant (PR) controller under the two-phase stationary coordinate is designed to track the ac reference current and to avoid the strong coupling brought about by the coordinate transformation. The limitations on improving steady-state performance of the PR controller is investigated and mitigated using a cascaded lead-lag compensator. In the z-domain, a straightforward procedure is developed to analyze and design the control-loop with the help of MATLAB/SISO software tools. In addition, robustness against parameter variations is analyzed. Finally, simulation and experimental results verify the proposed control scheme and design method.

면역 피드백 메카니즘에 기초한 비선형 PID 제어기 설계 (Design of Nonlinear PID Controller Based on Immune Feedback Mechanism)

  • 박진현;최영규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권3호
    • /
    • pp.134-141
    • /
    • 2003
  • PID controllers with constant gains have been widely used in various control systems due to its powerful performance and easy implementation. But it is difficult to have uniformly good control performance in all operating conditions. In this paper, we propose a nonlinear variable PR controller with immune feedback mechanism. An immune feedback mechanism is based on the functioning of biological T-cells, they include both an active term, which controls response speed. and an inhibitive term, which controls stabilization effect. Therefore, the proposed nonlinear PID controller is based on immune responses of biological. immune feedback mechanism which is the cell mediated immunity and In order to choose the optimal nonlinear PID controller games, we also propose the tuning algorithm of nonlinear function parameter in immune feedback mechanism. To verify performance of the proposed algorithm, the speed control of nonlinear DC motor are performed. Front the simulation results, we have found that the proposed algorithm is more superior to the conventional constant fain PID controller.

Hybrid GA-PID WAVENET 제어기를 이용한 모형 헬리콥터 시스템의 자세 제어 (Attitude Control of Helicopter Simulator System using A Hybrid GA-PID WAVENET Controller)

  • 박두환;지석준;이준탁
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권6호
    • /
    • pp.433-439
    • /
    • 2004
  • The Helicopter Simulator System is non-linear and complex. Futhermore, because of absence of its accurate mathematical model, it is difficult to control accurately its attitudes such as elevation angle and azimuth one. Therefore, we proposed a Hybrid GA-PID WAVENET(Genetic Algorithm Proportional Integral Derivative Wavelet Neural Network)control technique to control efficiently these angles. The proposed Hybrid GA-PID WAVENET is made through the following process. First, the WAVENET fundamental functions are defined. And their dilation and translation values are adjusted by GA to construct the optimal WAVENET controller. Secondly, the proportional, integral, and derivative gain coefficients of PR controller are tuned optimally. Finally, WAVENET controller which has a good transient characteristic and GA-PE controller which has a good steady state characteristic is adequately combined in hybrid type. Through the computer simulations, it is proved that the Hybrid GA-PE WAVENET control technique has a more excellent dynamic response than PID control technique and GA-PID one.

ORC 발전 시스템에서 주파수 가변형 PR 제어기와 정상분 추출을 이용한 발전기 속도추정 방법 (Speed Estimation Method of Turbine and Generator using Variable Frequency type PR controller and Positive-phase-sequence Component Computation in ORC Generation System)

  • 박형석;허홍준;김장목
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.377-378
    • /
    • 2015
  • 본 논문에서는 유기랭킨 사이클(organic rankine cycle: ORC) 발전 시스템에서 터빈과 발전기의 속도를 추정하는 방법을 제안한다. 다이오드 정류기에 의해 왜곡된 발전기 3상 단자 전압은 PLL 기법을 이용한 속도추정의 성능을 저하시키므로, 정상분 추출과 맥동성분 제거를 위한 상태관측기와 주파수 가변형 PR 제어기를 동기좌표계 PLL 기법에 적용하여 발전기의 속도를 추정한다. 제안하는 터빈과 발전기의 속도추정 방법은 실험 결과를 통해 그 성능을 검증한다.

  • PDF

A Design of SRM Controller using Microprocessor

  • Park, Joon-Hoon;Ahn, Jung-Soo;Han, Wun-Dong;Park, Boo-Chong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.2023-2026
    • /
    • 2002
  • This paper explains the study of controller design applied to SRM(Switched Reluctance Motor) concept. This controller executes controller algorithms via ${\mu}$-processor to increase stability and precise measurement, and VHDL (Very high speed integrated circuit Hardware Description Language) is designed to generate SRM driving signal. During initial period, SRM controller was designed to control .respective target RPM (Revolution per minutes) and PR (Proportional Integral Differential) coming from the PC(Personal Computer) monitor program, and receiving clockwise and counter-clockwise rotation signal and target RPM coming from the front panel, and receiving the location of rotational element and RPM generating from the position censor during activation period.

  • PDF