• 제목/요약/키워드: POOL

검색결과 2,530건 처리시간 0.026초

DEVELOPMENT OF A TWO-DIMENSIONAL THERMOHYDRAULIC HOT POOL MODEL AND ITS EFFECTS ON REACTIVITY FEEDBACK DURING A UTOP IN LIQUID METAL REACTORS

  • Lee, Yong-Bum;Jeong, Hae-Yong;Cho, Chung-Ho;Kwon, Young-Min;Ha, Kwi-Seok;Chang, Won-Pyo;Suk, Soo-Dong;Hahn, Do-Hee
    • Nuclear Engineering and Technology
    • /
    • 제41권8호
    • /
    • pp.1053-1064
    • /
    • 2009
  • The existence of a large sodium pool in the KALIMER, a pool-type LMR developed by the Korea Atomic Energy Research Institute, plays an important role in reactor safety and operability because it determines the grace time for operators to cope with an abnormal event and to terminate a transient before reactor enters into an accident condition. A two-dimensional hot pool model has been developed and implemented in the SSC-K code, and has been successfully applied for the assessment of safety issues in the conceptual design of KALIMER and for the analysis of anticipated system transients. The other important models of the SSC-K code include a three-dimensional core thermal-hydraulic model, a reactivity model, a passive decay heat removal system model, and an intermediate heat transport system and steam generation system model. The capability of the developed two-dimensional hot pool model was evaluated with a comparison of the temperature distribution calculated with the CFX code. The predicted hot pool coolant temperature distributions obtained with the two-dimensional hot pool model agreed well with those predicted with the CFX code. Variations in the temperature distribution of the hot pool affect the reactivity feedback due to an expansion of the control rod drive line (CRDL) immersed in the pool. The existing CRDL reactivity model of the SSC-K code has been modified based on the detailed hot pool temperature distribution obtained with the two-dimensional pool model. An analysis of an unprotected transient over power with the modified reactivity model showed an improved negative reactivity feedback effect.

지리산 주변 산지하천의 step-pool 구조 특성 (Characteristics of step-pool structure in the mountain streams around Mt. Jiri)

  • 김기흥;정혜련
    • 한국수자원학회논문집
    • /
    • 제51권4호
    • /
    • pp.313-322
    • /
    • 2018
  • Step의 높이는 하상재료 입경의 크기와 거의 같은 상관관계가 있으며, 하도경사에 따라 증가하고, 하도 폭과 step 파장은 거의 같은 크기로서 하도경사가 증가하면 step 파장은 감소하는 것으로 분석되었다. 하도 폭과 step 폭은 뚜렷한 상관관계가 있으며, 하도 폭의 증가에 따라 step 폭도 증가하는 것으로 분석되었다. 또한, step 파장은 하도 폭에 의하여 규모가 정해지고, step 높이는 step을 형성하는 암석의 크기에 의해 지배되기 때문에 step-pool의 종단면의 하상구조는 하도경사에 따라 변화하는 것으로 판단된다. Pool의 규모는 하도 폭, 입경 및 하도경사와 상관성이 큰 것을 확인하였다. 따라서 하천의 step-pool 구조 특성은 다양한 인자들의 영향을 받지만 대표적으로 입경, 하도 폭 및 하도경사로서 설명할 수 있는 것으로 분석되었다.

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

국제 탄소배출권 가격의 일물일가 검정 및 동태적 분석 (The Law of One Price and Dynamic Relationship between EU ETS and Nord Pool Carbon Prices)

  • 모정윤;양승룡;조용성
    • 자원ㆍ환경경제연구
    • /
    • 제14권3호
    • /
    • pp.569-593
    • /
    • 2005
  • 유럽배출권가래시장(EU ETS)과 Nord Pool에서 거래되고 있는 탄소배출권 가격자료를 이용하여 일물일가법칙 만족 여부를 검정하였다. 이를 위해 단위근 검정방법과 공적분 검정방법을 이용하였고, 인과성 분석, 충격반응분석과 분산분해 분석을 통해 두 시장간의 동태적 움직임을 분석하였다. 분석 결과 두 시장간 국제 배출권 가격 사이에는 일물일가의 법칙이 성립하며, EU ETS가 Nord Pool의 가격을 선도(lead)하고 EU ETS의 가격이 Nord Pool 가격의 움직임에 영향을 주는 것으로 분석되었다. 또한 Nord Pool은 자체 시장과 타 시장의 변동 모두에 큰 영향을 받는 시장인 반면, EU ETS는 외부의 충격에 큰 영향을 받지 않는 시장으로 분석되었다. 향후 유럽 지역에서의 배출권 시장이 EU ETS를 중심으로 통합되어 하나의 배출권 시장을 형성할 것으로 예측된다.

  • PDF

확산하는 액체질소의 증발에 관한 실험적 연구 (Experimental Study of the Evaporation of Spreading Liquid Nitrogen)

  • 김명배;최병일;김태훈;도규형;한용식;정경열
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.466-472
    • /
    • 2018
  • The investigation of cryogenic liquid pool spreading is an essential procedure to assess the hazard of cryogenic liquid usage. In this experimental study, to measure the evaporation velocity when the pool is spreading, liquid nitrogen was continuously released onto unconfined concrete ground. Almost all of the reported results are based on a non-spreading pool in which cryogenic liquid is instantaneously poured onto bounded ground for a very short period of time. A simultaneous measurement of the pool location using thermocouples and of the pool mass using a digital balance was carried out to measure the evaporation velocity and the pool radius. A greater release flow rate was found to result in a greater average evaporation velocity, and the evaporation velocity decreased with the spreading time and the pool radius.

마찰저항이 연속누출과 순간누출을 가지는 액체 풀의 확산에 미치는 영향에 대한 해석적 연구 (Effect of Frictional Resistance Force on a Liquid Pool Spreading Model with Continuous and Instantaneous Release)

  • 김태훈;최병일;김명배;도규형;한용식
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.487-494
    • /
    • 2013
  • In this study, solutions for a liquid pool spreading model with continuous and instantaneous release are discussed based on the model used in the FERC's report. The effects of the release time on the liquid pool volume and radius are investigated for the continuous release. For the continuous release with the frictional resistance force in the liquid pool spreading model, the vaporization time decreases as the release time increases. On the other hand, for the continuous release without the frictional resistance force in the liquid pool spreading model, the vaporization time increases as the release time increases. These phenomena are deeply related to the pool radius. In addition, the effects of the initial pool radius for the instantaneous release in the liquid pool spreading model are discussed. For the case with the frictional resistance force in the liquid pool spreading model, as reducing release time in the model with the frictional resistance force for the continuous release, the solution for a continuous release approaches to that for an instantaneous release. On the contrary to this, the pool volume and radius for the instantaneous release without the frictional resistance force are totally different from those for the continuous release without the frictional resistance force.

삼각형 형상의 풀 내에서 열원에 의한 자연대류 수치해석 (NATURAL CONVECTION IN A TRIANGULAR POOL WITH VOLUMETRIC HEAT GENERATION)

  • 김종태;박래준;김환열;송진호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.302-310
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

  • PDF

열원이 있는 삼각형 풀의 높은 Ra수 자연대류 (HIGH Ra NUMBER NATURAL CONVECTION IN A TRIANGULAR POOL WITH A HEAT GENERATION)

  • 김종태;박래준;김환열;홍성완;송진호;김상백
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.66-74
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

PDAODMRP: An Extended PoolODMRP Based on Passive Data Acknowledgement

  • Cai, Shaobin;Yang, Xiaozong;Wang, Ling
    • Journal of Communications and Networks
    • /
    • 제6권4호
    • /
    • pp.362-375
    • /
    • 2004
  • An ad hoc network is a multi-hop wireless network. Its limited bandwidth and frequently changing topology require that its protocol should be robust, simple, and energy conserving. We have proposed PoolODMRP to reduce its control overhead greatly by its one-hop local route maintenance. However, PoolODMRP still has some shortcomings. In this paper, we propose PDAODMRP (passive data acknowledgement ODMRP) to extend PoolODMRP. Compared with PoolODMRP, PDAODMRP has the following contributions: (1) It knows the status of its downstream forwarding nodes by route information collected from data packets instead of BEACON signal of MAC layer; (2) it max simplifies the route information collected from data packets by pool nodes; (3) it adopts a dynamic local route maintenance to enforce its local route maintenance; (4) it adopts the route evaluation policy of NSMP (neighbor supporting multicast protocol). Compared with PoolODMRP, PDAODMRP has lower control overhead, lower data delivery delay, and lower data overhead.

폐기물 열분해 용융소각로의 용탕 유지를 위한 실험적 연구 (Experimental Study for Keeping a Melting Pool in a Waste Pyrolysis Melting Incinerator)

  • 김봉근;박주원;류태우;양원;전금하
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.151-155
    • /
    • 2006
  • The large amount of energy is consumed in a process for keeping the high temperature melting pool. For this reason, in addition to the wastes input to keep the high temperature melting pool, it is necessary for an auxiliary fuel and LOx to throw into the melting pool. So in this study, using a new melting furnace system, the experiments to keep the melting pool with minimal energy without throwing an auxiliary fuel and LOx was carried out. Also it is hoped that the results of the experiment will be available to analyze keeping a melting pool and behavior in a melting furnace.

  • PDF