• Title/Summary/Keyword: POOL

Search Result 2,559, Processing Time 0.027 seconds

Computational Study of the Mixed Cooling Effects on the In-Vessel Retention of a Molten Pool in a Nuclear Reactor

  • Kim, Byung-Seok;Ahn, Kwang-Il;Sohn, Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.990-1001
    • /
    • 2004
  • The retention of a molten pool vessel cooled by internal vessel reflooding and/or external vessel reactor cavity flooding has been considered as one of severe accident management strategies. The present numerical study investigates the effect of both internal and external vessel mixed cooling on an internally heated molten pool. The molten pool is confined in a hemispherical vessel with reference to the thermal behavior of the vessel wall. In this study, our numerical model used a scaled-down reactor vessel of a KSNP (Korea Standard Nuclear Power) reactor design of 1000 MWe (a Pressurized Water Reactor with a large and dry containment). Well-known temperature-dependent boiling heat transfer curves are applied to the internal and external vessel cooling boundaries. Radiative heat transfer has been considered in the case of dry internal vessel boundary condition. Computational results show that the external cooling vessel boundary conditions have better effectiveness than internal vessel cooling in the retention of the melt pool vessel failure.

Characteristics of ATPases Present in Everted Membrane Vesicles of Helicobacter pylori

  • Yun, Soon-Kyu;Hwang, Se-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.7 no.3
    • /
    • pp.167-173
    • /
    • 1997
  • Everted membrane vesicles of Helicobacter pylori were prepared and the membrane-resided ATPases were characterized. For comparison, Escherichia coli membrane ATPases and hog gastric mucosal H,K-ATPase were employed. ATPase assay revealed that the composite enzyme pool was relatively low in specific activities, below 1/10 times than that found in E. coli. According to their inhibitory specificities, most of the ATPase pool appeared to belong to the P-type ATPase, sensitive to vanadate but not to azide. The enzyme pool was extraordinarily resistant against treatment by N,N'-dicyclohexylcarbodiimide (DCCD). Certain monovalent cations, e.g., $K^+$ or $NH_4^{+}$ stimulated the whole enzyme pool only in the presence of $Mg^{2+}$. On the contrary, $Ni^{2+}$ and $Zn^{2+}$ increased enzyme activity rather effectively without the aid of $Mg^{2+}$. Under a defined condition employed, H. pylori cells could retain the membrane ATPase pool to the extent of $17{\%}$ at pH 3.2. Moreover, its activity was most stable in acidic conditions (pH 5.4-6.4). However, cytoplasmic or peripheral ATPase pools were hardly detected under acidity (below pH 4.6).

  • PDF

A MECHANISM OF DEEP WELD PENETRATION IN GAS TUNGSTEN ARC WELDGING WITH ACTIVATING FLUX

  • Manabu Tanaka;Hidenori Terasaki;Masao Ushio;John J. Lowke;Yang, Chun-Li
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.76-81
    • /
    • 2002
  • The dramatic increase in the depth of a weld bead penetration has been demonstrated by welding a stainless steel in GTA (Gas-Tungsten-Arc) process with activating flux which consists of oxides and halides. However, there is no commonly agreed mechanism fer the effect of flux on the process. In order to make clear the mechanism, each behavior of the arc md the weld pool in GTA process with activating flux is observed in comparison with a conventional GTA process. A constricted anode root is shown in GTA process with the activating flux, whereas a diffuse anode root is shown in the conventional process. These anode roots are related strongly to metal vapor from the weld pool and the metal vapor is also related to temperature distributions on the weld pool surface. Furthermore, it is suggested that a balance between the Marangoni force and the drag force of the cathode jet should dominate the direction of re-circulatory flow in the weld pool. The electromagnetic force encourages the inward re-circulatory flow due to the constricted anode root in the case with flux. The difference in flow direction in the weld pool changes the geometry or depth/width ratio of weld bead penetration.

  • PDF

Nitrogen and Phosphorus Cycles in the Glyceria leptolepis Ohwi Population at the Mt. Geumoh Basin (금조산 분지의 왕미꾸리광이 ( Glyceria leptolepis Ohwi ) 개체군의 실소 및 인의 순환)

  • Lyu, Seung-Won;Seung-Dal Song
    • The Korean Journal of Ecology
    • /
    • v.11 no.2
    • /
    • pp.55-64
    • /
    • 1988
  • The seasonal pattern of pool size and withdrawal from senescing or stroage organ, and the annual magintude of internal-and plant-soil cycles for nitrogen and phosphorus in a Glyceria leptolepis Ohwi population in a marsh of the Mt. Geumoh were investigared. The population pool changed from initial size of 6.8 to the maximum of 16.1gN$m^{-2}$ for N and from 1.7 to 3.9g Pm$m^{-2}$ for P, maintaining far higher relative pool size during the first half of the growth period as compared with that for biomass. A sharp increase in N and P pool was noticed in early spring before the biomass growth was recognized, The major process supplying the demand for N and P changed as the growth progressed showing the order; absorption-withdrwal-absorption-with-drawal. The annual magnitude of plant-soil cycle for N and P was 18.0-19.1 and 2.9-3.3gm$m^{-2}$, accounting for 3 and 5% of each nutrient pool in 0-20 cm humus layer, respectively. The higher exent of internal cycle and the lower rate of annual turnover for P(1.08) as compared with those for N may suggest that this population conserves and reuses P more efficiently than N.

  • PDF

Investigation of marine bacteria for the food of Tigriopus japonicus Mori(Harpacticoida) (동물플랑크톤 Harpacticoid, Tigriopus japonicus Mori 배양에 유효한 해양세균의 탐색)

  • Lee Won-Jae;TAGA Nobuo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.1
    • /
    • pp.50-56
    • /
    • 1988
  • In order to fine some proper bacterial food for Tigriopus japoncus, bacterial flora of the tide pool inhabited by the copepod has been isolated and tested as bacterial food. Food effect and optimum density of the bacteria in terms of survival rate of the copepod was measured in the larval and the adult stages. Among the 264 strains of isolated bacteria, Acinetobacter spp. Moraxella, spp., Flavobacterium spp. and Pseudomonas spp. were certified as effective food for the copepod. According to the experimental results, Acinetobacter spp. AG-3 was the most effective food for all the stages from nauplius to adult, while Moraxella spp. and Flavobacterium spp. were effective for copepodite stage, and Pseudomonas spp. for the adult stage only. The optimum density of bacteria for the food was about $10^6\;cell/ml$, which was the same average density of bacteria in the tide pool.

  • PDF

Pool Boiling Heat Transfer Coefficients of R1234yf on Various Enhanced Surfaces (열전달 촉진 표면에서 R1234yf의 풀 비등 열전달계수)

  • Lee, Yohan;Kang, Dong Gyu;Seo, Hoon;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.143-149
    • /
    • 2013
  • In this work, nucleate pool boiling heat transfer coefficients (HTCs) of R134a and R1234yf are measured, on flat plain, 26 fpi low fin, Turbo-B, Turbo-C and Thermoexcel-E surfaces. All data are taken at the liquid pool temperature of $7^{\circ}C$, on a small square copper plate ($9.53mm{\times}9.53mm$), at heat fluxes from $10kW/m^2$ to $200kW/m^2$, with an interval of $10kW/m^2$. Test results show that nucleate boiling HTCs of all enhanced surfaces are greatly improved, as compared to that of a plain surface. Nucleate pool boiling HTCs of R1234yf are very similar to those of R134a, for the five surfaces tested.

PARTICLE POOL SIZE AND TURNOVER RATE OF INGESTA IN THE RETICULO-RUMEN OF NORMAL AND ABSESSED SHEEP

  • Okamoto, M.;Miyazaki, H.;Oura, R.;Sekine, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.3
    • /
    • pp.243-246
    • /
    • 1990
  • Sixteen mature sheep were fed chaffed orchardgrass hay once a day for 7 days. In 7th day, four sheep were slaughtered either prior to eating, 2, 8 or 16 hours after the commencement of eating to measure digesta pool size and particle size distribution in the reticulo-rumen. One sheep slaughtered at 8 hours after feeding had absesses at the cardia and in the lungs and could not ruminate normally. Time spent eating and rumination in the sheep on the day before slaughtering were 85 and 29 (pseudo-rumination 227) minutes a day, compared to those were 112 and 277 minutes in the other animals, respectively. Total actual chewing time in the sheep with absesses and the other animals were 98 and $373{\pm}132$ minutes, respectively. Dry matter(DM) intake in the sheep was $2.9g/kgBW^{0.75}$ which was only about 17% of that in the other animals. The pool sizes of reticulo-rumen DM and neutral detergent fiber (NDF) were somewhat smaller in the sheep than the others. The pool sizes of large particle (>1.18mm) DM and NDF in the animal were similar with those in the other animals. Mean DM retention time in the sheep was 207.4 hours which was about 4.2 times longer than that in the other animals.

A Study on the Flame Behavior of Whirl Eire and Pool Fire (Whirl Fire와 Pool fire의 화염 거동에 관한 연구)

  • Oh Kyu-Hyung;Kang Youn-Ok;Lee Sung-Eun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.45-50
    • /
    • 2004
  • 4-panel of 1m height and 45cm width were fixed on the $40cm{\times}40cm$ bottom plate and the opening of the panel comer was 5cm. Diameter of stainless vessel is loom and its height is 2cm and it located at the center of the bottom plate. 78mL liquid fuel was filled in the vessel and its depth was 1cm. Flame temperature was measured with K type thermocouple, and radiation heat of flame was measured with heat flux meter. Flame height and its behavior was visualized with video camera. and mass burning rate was measured by fuel combustion time. According to the development of fire, flame swirling was begin. From the experiment the mass burning rate was larger and the height of flame was higher than the usual pool fire flame. Flame temperature and heat flux also increased far more than the pool fire. Consequently the swirling air flow through the openings between the panel and thermal buoyance contribute to increase of heat release rate, flame length and mass burning rate.

Pool Boiling Heat Transfer Coefficients Upto Critical Heat flux (임계 열유속 근방까지의 풀 비등 열전달계수)

  • Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.571-580
    • /
    • 2008
  • In this work, pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of differing vapor pressure are measured on horizontal smooth square surface of 9.52 mm length. Tested refrigerants are R123, R152a, R134a, R22, and R32 and HTCs are taken from $10\;kW/m^2$ to critical heat flux of each refrigerant. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and by thermocouples in the liquid pool. Test results show that pool boiling HTCs of refrigerants increase as the heat flux and vapor pressure increase. This typical trend is maintained even at high heat fluxes above $200\;kW/m^2$. Zuber's prediction equation for critical heat flux is quite accurate showing a maximum deviation of 21% for all refrigerants tested. For all refrigerant data up to the critical heat flux, Stephan and Abdelsalam's well known correlation underpredicted the data with an average deviation of 21.3% while Cooper's correlation overpredicted the data with an average deviation of 14.2%. On the other hand, Gorenflo's and lung et al.'s correlation showed only 5.8% and 6.4% deviations respectively in the entire nucleate boiling range.

Simulation of Pool Fire with Two Rooms Using FDS Model (화재분석모델을 이용한 이중격실화재 검증분석)

  • Kim, Bong-Hyun;Bae, Yong-Bum;Ryu, Su-Hyun;Lee, Gong-Hee;Kim, Yun-Il;Moon, Chan-Ki;Park, Jong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1332-1337
    • /
    • 2008
  • Fire model shall be verified and validated to reliably predict the consequences of fires within its limitations. This study aims to predict pool fire with two rooms using FDS and to coompare FDS simulation results with PRISME experimental data which can be applicable to the fire of nuclear power plant facility. Four different sizes of grid (0.08m, 0.1m, 0.125m, 0.2m) are used in the simulation and the simulated results of specific quantities such as temperature, chemical composition, heat flux and heat release rate are compared to the experimental data. From this study, the FDS simulation results with the finer grid resolution show better similarity and trend with pool fire experimental data. The sensitivity analysis and the selection of the proper size grid are essential to predict the consequences of pool fire with two rooms reliably.

  • PDF