• 제목/요약/키워드: POLLUTANTS

검색결과 4,233건 처리시간 0.032초

국내 음용수의 안전성 (Safety of Drinking Water in Korea)

  • 권숙표
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.1-20
    • /
    • 1997
  • The present standard of drinking water quality is not reached to the guidelines of WHO and US EPA recommended. The appraisal of safety is not appropriate by the results of intermittent and limitted analysis. 45 items of drinking water quality are regulated in the Korean standard and 9 items for inspection designated by Seoul City. This report is the results of analysis of the water quality in the water stations of Seoul which are concerned with the items of Korean water quality standard and the priolity pollutnats recommended by WHO. In the results, 45 items of water quality, and the priolity pollutants were not exceeded to the standard and criteria, while DDT, heptachlor-epoxide, THMs, benzo(a)pyrene, Ba, Al, Gross beta, $^{226}$Ra, $^{90}$Sr were detected, the levels were not exceeded to the WHO guidelines. In ordes to evalute the safety of drinking water quality, besides of the existed items of standard, new hazardouse pollutants should be considered monitored continenously. For the regulation of hazardous pollutants, it may be introduced from the risk assessment. According to the relevant assessment, the acceptable risk of pollutants estimated could be applied to set the water quality standard or recommendations or quidelines as well as the number of monitoring.

  • PDF

A Study on the Relationship between the Traffic Signal System and the Air Pollutants emitted by the Motor Vehicles at Intersection

  • Hong, Min-Sun;Woo, Wan-Gi;Park, Jong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제9권E호
    • /
    • pp.364-372
    • /
    • 1993
  • The purpose of this study is to analyze traffic patterns by use of TRANSYT-7F Model, and to choose the optimum traffic-light cycle length and cycle splite to improve traffic flow and air quality at Samsung Intersection in Seoul. Emission rates of air pollutants are calculated for three time segments 0700-0900, 0900-1800 and 1800-2000. The traffic volume correlated reasonably well with air pollutants emitted ; however, the phasing and timing of traffic signals was found to equally be important. The results of performance with optimal setting indicate that the best cycle length were 80sec(0700-0900), 95sec(0900-1800) and 90sec(1800-2000), res-pectively. As expected the highest emissions of air pollutants were observed during the evening rush hours (1800-2000). A properly designed signalized intersection can help reduce traffic delay, driver discomfort, fuel consumption, and air pollution by efficiently the capacity of existing intersection.

  • PDF

철도 디젤차량에서 배출되는 가스상 오염물질의 배출량 추정 (Estimation of Gases Air Pollutants Emission Rates Exhausted from Railroad Diesel Rolling Stocks)

  • 박덕신;배상호;정우성;김태오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.467-472
    • /
    • 2003
  • Of those off-road diesel engines, the railroad diesel rolling stocks (RDRS) for passenger and freight transportation become a growing issue since they are emitting enormous amounts of various air pollutants. Furthermore, up to the present time, emissions from these sources are not well controlled. One of main purposes in this study is to develop emission factors for the RDRS and to estimate a total amount of major air pollutants from the RDRS in Korea. Prior to develop a Korean mode emission factor, the emission factor from the USEPA was simply applied for comparative studies. As a conclusion, based on the emissions calculated from both the USEPA mode and the KoRail mode, the RDRS is considered as one of significant mobile sources of major air pollutants including NOx and CO, and thus management plans and control strategies for the RDRS must be established to improve air quality near. future in Korea.

  • PDF

인공습지에서의 물질순환에 관한 연구 (Cycling of Matters in the Constructed Wetland)

  • 김동억;박제철
    • 한국환경과학회지
    • /
    • 제29권3호
    • /
    • pp.299-306
    • /
    • 2020
  • This study analyzed the changes in the concentrations of the pollutants of constructed treatment wetlands which come from the discharge water of a sewage treatment plant. According to the results of budgets in constructed wetlands, the net production of the organic carbon, nitrogen and phosphorus were 368 kgC/month, 306 kgN/month and -49 kgP/month, respectively. The high particle form of pollutants are mostly removed due to settlement and absorption when passing through wetlands, but because a low processing efficiency for pollutants was shown when sewage treatment plant wastewater flows in, there is a need for a water management system that can reduce the organic matter load through monitoring. The low removal efficiency of constructed wetlands were caused by both structural and operational problems. Therefore, to enable to play a role as a reduction facility of pollutants, an appropriate design and operation manuals for constructed wetlands is urgently needed.

건설장비의 배출가스 데이터 기반 대기오염물질 배출량 예측 시스템 (The Collected data-based Air Pollutant Emission Prediction for construction equipment in Construction Sites)

  • 노재윤;김유진;김수민;한승우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.86-87
    • /
    • 2021
  • As non-road mobile pollutants such as construction equipment are emerging as the main cause of air pollutants emission, construction equipment regulations are gradually strengthening. Research was conducted by correcting the emission coefficient to calculate and predict air pollutant emissions of construction equipment, but it did not reflect site variables such as field and equipment conditions that affect actual emissions. This study derived an Artificial Neural Network emission prediction model based on the actual emission data of excavators and trucks measured at the site and proposed a platform to predict the emission of air pollutants at the site according to the working size and conditions. Through this, it is possible to establish an eco-friendly process plan using a model from the construction plan.

  • PDF

배출허용기준 강화에 따른 차속별 경유 중형트럭의 유해대기오염물질 배출특성 (Speed-dependent Emission Characteristics of the Hazardous Air Pollutants from Diesel Medium-duty Trucks according to Emission Standards)

  • 홍희경;정성운;손지환;문태영;이상은;문선희;윤현진;김정수;김정화
    • 한국분무공학회지
    • /
    • 제20권2호
    • /
    • pp.121-129
    • /
    • 2015
  • This study was designed to investigate the emission characteristics of unregulated pollutants (Aldehyde, VOCs, PAHs) as well as regulated pollutants (CO, HC, NOx and PM) from diesel medium-duty trucks. The emission characteristics of unregulated and regulated pollutants were assessed based on regulation standards (EURO 4 and EURO 5) and intake weight (2.5 ton and 5 ton). The results show that unregulated and regulated pollutants remained almost unchanged at higher speeds but decreased at below 23.5 km/h. Reduction in unregulated and regulated pollutants was noticeable in vehicles of recent regulation standards and light intake weight. The analysis of aldehyde using UPLC showed that formaldehyde and acetaldehyde of aldehyde were most dominant. The GC/MS analysis showed that benzene, toluene, ethylbenzene and xylene of VOCs was over 80% followed by toluene, xylene, ethylbenzene and benzene. In addition, the analysis of PAHs using GC/TOF-MS indicated that bi- and tricyclic aromatic ring of aromatic compounds was 73% and 53% at 2.5 ton and 5 ton vehicles, respectively. The results of this study will be contributed to establish HAPs inventory.

황사현상에 의한 대기오염물질의 농도분포 특성에 관한 연구 (A Study on the Concentration Distribution Characteristics of Air Pollutants by Yellow Sand Phenomenon)

  • 이용기;김종찬;최승석;임홍빈;최양희;이수문
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.71-78
    • /
    • 2002
  • This study was conducted to evaluate the concentration distribution characteristics of air pollutants by the yellow sand from China. The concentrations and chemical properties of FPM contained in the yellow sand were compared with those of air pollutants when having no yellow sand in order to estimate the variation characteristics and the originated source of air pollutants moved by yellow sand. The concentrations of PM-2.5 and PM-10 contained in the yellow sand showed an increase of 2.3 to 2.7 times than usual, and the concentrations of NO2 and SO2 in the gaseous pollutants showed an increase of about 1.6 times by yellow sand, and thus the air contamination was much influenced by yellow sand phenomenon. The concentrations of inorganic elements contained in FPM from the yellow sand showed a higher concentration variation in the order of Al>Mg>Zn>Pb than usual. The concentration coefficient of air aerosol during the yellow sand period showed that Na, K, Ca, Mg and Fe were originated from natural source, and Pb, Cr, Cd, Cu and Zn were originated from artificial source for inorganic elements. The correlation analysis between FPM and inorganic elements showed in the descending order of Al>K>Pb>Mg, and thus the deposited amount of Pb was influenced by that of yellow sand. The average concentrations of PM-10 measured during the yellow sand period exceeded the Korea Air Environmental Standard and showed a excess rate of 3.4 times in the maximum but the average concentrations of PM-2.5 showed within the United States Air Environmental Standard.

하절기 천안 제 2산업단지의 대기오염확산 및 악취물질에 관한 연구 (Dispersion of Air Pollutants Dispersion and Odorous Materials in Cheon-an Second Industrial Complex)

  • 정진도;홍정희;김수영;김정태;최소진
    • 대한환경공학회지
    • /
    • 제28권12호
    • /
    • pp.1316-1322
    • /
    • 2006
  • 본 연구는 천안 제 2산업단지에서 배출되는 대기오염물질과 악취물질을 분석하고 대기오염물질의 확산모델링을 수행하고자 함을 목적으로 한다. 측정은 12가지 지정 악취물질과 대기오염물질의 농도에 대하여 2005년 8월에 수행하였다. 악취물질은 주요 배출원을 중심으로 부지경계선에서 측정 및 분석을 실시하였으며, 대기오염물질은 ISCST3모델을 이용하여 대기오염확산 농도를 계산하였다. Air Master는 현재 국내 대기환경영향평가에 많이 사용되고 있고 U.S. EPA의 추천모델인 ISC3모델 중 ISCST3모델을 사용하였다. 따라서 천안 제 2산업단지를 대상으로 하절기 대기오염물질을 측정하여 모델링 하고 악취물질은 시료채취 후 분석을 실시하여 주변 지역에 영향을 끼치는 대기오염물질과 악취발생물질의 종류와 발생 원인을 규명하고자 한다.

서울지역 공공청사 민원실의 겨울철 실내공기질에 관한 연구 (Study on Indoor Air Pollutants of Public Service Centers in Winter, Seoul)

  • 전재식;김미형;이주열;전명진;류인철;박덕신;최한영
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.569-579
    • /
    • 2011
  • This study evaluated the indoor air quality of 26 government offices located in Seoul. The pollutant samples were taken from Jan. 13th to Jan. 29th and Feb. 20th to Feb. 23rd, 2010 in the offices. The target indoor pollutants for this study were $PM_{10}$, formaldehyde, carbon monoxide, carbon dioxide, total bacteria counts, total volatile organic compounds, radon, nitrogen dioxide, ozone, and asbestos which were controlled by the indoor air quality law for the multiple-use facilities management. The results of this study showed that some pollutants of the 38.5% offices exceeded the standards of the air quality guideline. The correlation analysis of the same pollutants between indoor and outdoor represented that $NO_2$ (r=0.629, p<0.05) and $O_3$ (r=0.459, p<0.01) were significant, however, $PM_{10}$ and CO were not. The correlation analysis between different pollutants showed that CO and TVOC (total volatile organic compounds: r=0.724; p<0.01), CO and $NO_2$ (r=0.674; p<0.01), HCHO and humidity (r=0.605; p<0.01), $CO_2$ and TVOC (r=0.534; p<0.01), TBC (total bacteria counts) and Asbestos (r=0.520; p<0.01) were significant. The energy-saving system of government buildings in winter caused under-ventilated and poor air quality. This study suggests that the concentrations of radon and $CO_2$ should be used as an indicator for monitoring indoor air quality and maintaining effective ventilations.