• Title/Summary/Keyword: POLLUTANT MANAGEMENT

Search Result 673, Processing Time 0.026 seconds

Emission Estimation and Exposure to Hazardous Gaseous Pollutants Associated with Use of Air Fresheners Indoors (실내 방향제 사용에 의한 유해 가스상 오염물질 배출 산정 및 노출 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Kwon, Gi-Dong;Lee, Jong-Hyo
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.2
    • /
    • pp.137-148
    • /
    • 2009
  • This study quantitatively investigated the emissions of indoor air pollutants associated with the utilization of air fresheners indoors, and evaluated individual exposure to five specified indoor air pollutants, which were chosen on the basis of selection criteria. An electrically-polished stainless steel chamber (50L) was employed to achieve this purpose. Test air fresheners were selected through three steps: first, on the basis of market sales; second, on the basis on a preliminary head-space study; and lastly, on the basis of emissions of toxic compounds (benzene, ethyl benzene, limonene, toluene, and xylene). The empirical mathematical model fitted well with the time-series concentrations in the environmental chamber (in most cases, determination coefficient, $R^2{\gtrsim}$0.9), thereby suggesting that the empirical model was suitable for testing emissions. The concentration equilibrium appeared 180 min after the introduction of sample air fresheners into the chamber. Both the chamber concentrations of emission rates or factors varied greatly according to air freshener type. It is noteworthy that although benzene, ethyl benzene, toluene, and xylene were emitted from all test air fresheners, their exposure levels were not significant enough to result in any significant health risk. However, certain type of air fresheners were observed to emit significant amount of limonene, which is potentially reactive with ozone to generate secondary pollutants with oxidants such as ozone, hydroxyl radicals, and nitrogen oxides. The exposure levels to limonene associated with the utilization of three air fresheners were estimated to be 13 to 175 times higher than that of other air fresheners. This information can help consumers to select low-pollutant-emitting air fresheners.

Characteristics of Water Quality by Storm Runoffs from Intensive Highland Agriculture Area in the Upstream of Han River Basin (한강상류 고령지 농업지역에서의 강우시 비점오염 유출 특성)

  • Jung, Sungmin;Jang, Changwon;Kim, Jai-Ku;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.102-111
    • /
    • 2009
  • Turbid storm runoff from intensive highland agriculture area has emerged as the major problem of water quality deterioration in the upstream region of the Han River. High slope of the upland combined with high rate of fertilization and intensive plowing causes high rate of soil erosion, and subsequently high suspended sediment and phosphorus content in the runoff water. The variations of water quality during rain spells were surveyed for two years (2005 and 2006) in the Jawoon Stream that is one of hot spots of intensive horticulture discharging turbid storm runoff. SS and TP showed large increase according to the increase of flow rate, whereas TN and BOD showed less fluctuations. Mean EMCs of SS and TP measured for nine rain events were as high as $207mgSS{\cdot}L^{-1}$ and $0.27mgP{\cdot}L^{-1}$, respectively. The export coefficient of SS and TP per area of cultivated field were calculated as $11,912kgSS{\cdot}yr^{-1}{\cdot}km^{-2}$ and $785kgP{\cdot}yr^{-1}{\cdot}km^{-2}$, repectively, which are significantly higher than reports of other area. It can be concluded that SS and TP in the runoffs were high enough to impose major threat to aquatic habitats, and the highland agriculture should be the main target of water quality management or habitat conservation in the study area.

A Study on the Water Quality Relationship between Continuous Dam Discharge and Downstream in North Han River (북한강에 연속된 댐 구간 방류수와 하류 하천간 수질 관계 분석 연구)

  • Kim, Ji Won;Lee, Hye Won;Lee, Yong Seok;Choi, Jung Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.89-97
    • /
    • 2020
  • North Han River is a very unique type of water system, where Hwacheon, Chuncheon, Soyanggang, Euiam and Cheongpyeong Dams are located consecutively. These dams are operated differently in the amount of discharge and release schedule according to their structure and purpose of use. They have different water quality characteristics depending on external pollutant inflow and internal mixing condition. Therefore, this study investigated the relationship between the upper dam and down stream river with respect to water quality indicators, such as water temperature, electrical conductivity, BOD, COD, TN and TP of the North Han River. The similarities and correlations representing the relationship were analyzed by Pearson's correlation r and t-test. The data was taken from the Ministry of Environment's water quality monitoring from 1999 to 2018. The results show that water temperature and electrical conductivity of the dam and river are similar and correlated. However, it turned out that there was no similarities and correlations in BOD, COD, TN and TP that are significantly affected by subaqueous reaction mechanism. The results of this study present the impact of the dam on the water quality of North Han River, which can be used as useful data for management of water quality.

Estimation of Reservoir Discharge to Support TMDL Management in the Geum River Basin (금강수계 오염총량관리를 고려한 저수지 방류량산정)

  • Noh Joon-Woo;Kim Soo-Jun;Kim Jeong-Kon;Koh Ick-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.7 s.168
    • /
    • pp.627-636
    • /
    • 2006
  • This study estimates adequate discharge to meet the specified target water quality concentration using the pollutant load of the Geum river basin given in TMDL (Total Maximum Daily Load) report. During the 1st phase, BOD is chosen as a target water quality constituent under regulation of the Ministry of Environment in Korea. BOD, TN, and TP loads estimated based on the TMDL and provincial zones were re-distributed for 10 major tributaries, and the remaining areas along the main river are classified as 15 incremental flow areas. Water quality modeling was conducted using Qual2E for the low flow period of a year (i.e. $March{\sim}April$). The results of the model simulation showed that about 30 cms from the Daechung dam would be sufficient to satisfy the target water quality in the Geum river downstream of the Daechung multipurpose Dam.

A Study on International Trend and Korean Measures regarding Ship Recycling (선박 재활용에 관한 국제동향 및 우리나라의 대응방안 연구)

  • Yun, Jong-Hwui;Gug, Seung-Gi;Lim, Jae-Dong;Ha, Min-Jae;Moon, Jung-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.69-75
    • /
    • 2007
  • Guidelines on ship recycling are adopted internationally. UNEP adopted 'Basel Convention', providing Environmentally Sound Management(ESM) of facilities and recommendations. IMO adopted 'Guidelines on Ship Recycling', providing measures for worker's safety, how to control pollutant materials and the meaning of 'Green Passport'. IMO Convention (draft) is in progress. ILO adopted ILO Guideline', providing how to make sure safety and health for workers in shipbreaking. But Republic of Korea goes against the stream and there is much to be desired. At this point of time, we carried out a study on international trend regarding ship recycling, a plan to cope with international trend, and it is considered to be necessary to establish a special law on ship recycling.

  • PDF

A Non-parametric Analysis of the Tam-Jin River : Data Homogeneity between Monitoring Stations (탐진강 수질측정 지점 간 동질성 검정을 위한 비모수적 자료 분석)

  • Kim, Mi-Ah;Lee, Su-Woong;Lee, Jae-Kwan;Lee, Jung-Sub
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2005
  • The Non-parametric Analysis is powerful in data test especially for the non- normality water quality data. The data at three monitoring stations of the Tam-Jin River were evaluated for their normality using Skewness, Q-Q plot and Shapiro-Willks tests. Various constituent of water quality data including temperature, pH, DO, SS, BOD, COD, TN and TP in the period of January 1994 to December 2004 were used as dataset. Shapiro-Willks normality test was carried out for a test 5% significance level. Most water quality data except DO at monitoring stations 1 and 2 showed that data does not normally distributed. It is indicating that non-parametric method must be used for a water quality data. Therefore, a homogeneity was conducted by Mann-Whitney U test (p<0.05). Two stations were paired in three pairs of such stations. Differences between stations 1, 2 and stations 1, 3 for pH, BOD, COD, TN and TP were meaningful, but Tam-Jin 2 and 3 stations did not meaningful. In addition, a narrow gap of the water quality ranges is not a difference. Categories in which all three pairs of stations (1 and 2, 2 and 3, 1 and 3) in the Tam-Jin River showed difference in water quality were analyzed on TN and TP. The results of in this research suggest a right analysis in the homogeneity test of water quality data and a reasonable management of pollutant sources.

A Study on Redesign of Spatial Data Structure of Korean Reach File for Improving Adaptability (하천망분석도(KRF)의 활용성 증대를 위한 공간데이터 구조 개선에 관한 연구)

  • Song, Hyunoh;Lee, Hyuk;Kang, Taegu;Kim, Kyunghyun;Lee, Jaekwan;Rhew, Doughee;Jung, Dongil
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.511-519
    • /
    • 2016
  • National Institute of Environmental Research (NIER) has developed the Korean Reach File (KRF) for scientific and systematic analysis of variables related to water quality, pollutant sources and aquatic ecosystems in consideration of steam reach networks. The KRF provides a new framework for data production, storage, management and analysis for water related variables in relation to spatial characteristics, connections, and topologies of stream reaches. However, the current version of KRF (ver.2) has limited applicability because its nodes include not only the stream points based on topological characteristics but also those based on water quality monitoring stations, which may undermine its generality. In this study, a new version of KRF (ver.3) was designed and established to overcome the weak point of version 2. The version 3 is a generalization of the old KRF graphic data and it integrates the attribute data while separating it from the graphic data to minimize additional work that is needed for data association and search. We tested the KRF (ver.3) on actual cases and convenience and adaptability for each application was verified. Further research should focus on developing a database link model and real-world applications that are targeted to process event data.

The Variation of Water Quality due to Sulice Gate Operation in Shiwha Lake (시화호의 배수갑문 운용에 따른 수질변화)

  • 김종구;김준우;조은일
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1205-1215
    • /
    • 2002
  • To evaluate the change for water quality after the water gate operation in Shiwha lake, in situ survey were conducted on september in 2000 and January, march, jane in 2001. Chemical characteristics and eutrophication level was estimated from the survey data. The water quality of the Shihwa lake was greatly affected by pollutant load from rainfall, and formation of stratification in summer and winter was increased to effect on nutrient release from sediment. Especially, high concentration of chlorophyll-a was occurred in autumn, due to increased nutrient, high water temperature and low salinity after rainfall runoff. The mean concentration of DIN, DIP were 0.346mg/L, 0.0217mg/L in surface water and 0.826mg/L, 0.0415mg/L in bottom water, respectively, which were over III grade of seawater standard. Also high percentage of ammonia nitrogen to DIN in bottom water for autumn and winter was affected by released nutrient from sediment. Correlation analysis of chlorophyll-a versus TSS was shown that organic matter was affected by autochthonous organic matter stem from the algae, these factor showed reverse correlation about salinity. Closely correlations among to the water quality constituent in continuity survey was appeared. The results of eutrophication index estimation showed the high potentiality of red tide occurrence in Shiwha lake, particularity in summer or fall. Overall water quality was greatly improve to compared with measuring data during 1997~1998 at the beginning water gate operation, which reported by KORDI. Therefore, to improve of water quality in Shiwha lake, we need to establish of management plan about nutrient release from sediment, rainfall runoff, maximum of seawater exchange.

Evaluation of Exposure to Indoor Volatile Organic Compounds by Utilizing Emission Characteristics and Emission Factor of Household Mosquito Repellents (가정용 모기살충제의 배출 특성 및 배출계수를 이용한 실내 휘발성 유기화합물질 노출 평가)

  • Jo, Wan-Kuen;Lee, Jong-Hyo
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1123-1134
    • /
    • 2009
  • This study was designed to evaluate qualitatively and quantitatively the pollutant compositions, which were emitted from three types of mosquito repellents(MRs)(mat-, liquid-vaporized, and coil-type) by utilizing a 50-L environmental chamber. A qualitative analysis revealed that 42 compounds were detected on the gas chromatography/mass spectrometer system, and that the detection frequency depended upon chemical types. Nine of the 42 compounds exhibited a detection frequency of 100%. Four aromatic compounds(benzene, ethyl benzene, toluene, and xylene) were detected in all test MRs. The concentration equilibriums in the environmental chamber were achieved within 180 min after sample introduction. The coil-type MR represented higher chamber concentrations as compared with the mat- or liquid-vaporized-type MR, with respect to the target compounds except for naphthalene. In particular, the chamber concentrations of ethyl benzene, associated with the use of coil-type MR, were between 0.9 and $65\;mg\;m^{-3}$ whereas those of mat- and liquid-vaporized-type MRs we~e between 0.5 and $2.0\;mg\;m^{-3}$and 0.3 and $1.4\;mg\;m^{-3}$, respectively. However, naphthalene concentrations in the chamber, where a liquid-vaporized-type MR was placed, were measured as between 17.8 and $56.3\;mg\;m^{-3}$, but not detected in the chamber, where a mat- or coil-type MR was placed. The empirical model fitted well with the time-series concentrations in the environmental chamber(in most cases, determination coefficient, $R^2$ ≿ 0.9), thereby suggesting that the model was suitable for testing emissions. In regards to the target compounds except for benzene, although they were emitted from the MRs, health risk from individual exposure to them were estimated not to be significant when comparing exposure levels with no observed adverse exposure levels or lowest observed adverse exposure levels of corresponding compounds. However, it was concluded that the use of MRs could be an important indoor source as regards benzene.

Relation with Activity of Road Mobile Source and Roadside Nitrogen Oxide Concentration (도로이동오염원의 활동도와 도로변 질소산화물 농도의 관계)

  • Kim, Jin Sik;Choi, Yun Ju;Lee, Kyoung Bin;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Ozone has been a problem in big cities. That is secondary air pollutant produced by nitrogen oxide and VOCs in the atmosphere. In order to solve this, the first to be the analysis of the $NO_x$ and VOCs. The main source of nitrogen oxide is the road mobile. Industrial sources in Seoul are particularly low, and mobile traffics on roads are large, so 45% of total $NO_x$ are estimated that road mobile emissions in Seoul. Thus, it is necessary to clarify the relation with the activity of road mobile source and $NO_x$ concentration. In this study, we analyzed the 4 locations with roadside automatic monitoring systems in their center. The V.K.T. calculating areas are set in circles with 50 meter spacing, 50 meter to 500 meter from their center. We assumed the total V.K.T. in the set radius affect the $NO_x$ concentration in the center. We used the hourly $NO_x$ concentrations data for the 4 observation points in July for the interference of the other sources are minimized. We used the intersection traffic survey data of all direction for construction of the V.K.T. data, the mobile activities on the roads. ArcGIS application was used for calculating the length of roads in the set radius. The V.K.T. data are multiplied by segment traffic volume and length of roads. As a result, the $NO_x$ concentration can be expressed as linear function formula for V.K.T. with high predictive power. Moreover we separated background concentration and concentrations due to road mobile source. These results can be used for forecasting the effect of traffic demand management plan.