• 제목/요약/키워드: POLLUTANT MANAGEMENT

검색결과 673건 처리시간 0.029초

오염할당부하량의 초과현황 및 초과해소를 위한 삭감계획 유형에 따른 페널티 적용방안 (Excessive State of Pollutant Load Allocation and Penalty Application Schemes based on Pollutant Reduction Plan Types for Solving Excessive Problem of Allocation)

  • 박재홍;박배경;오승영;황하선;이재관
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.66-73
    • /
    • 2013
  • Total Maximum Daily Loads (TMDLs) system was introduced to manage pollution load of watershed and to improve water quality of unit watershed so that it is possible to protect dringking water soureces. Load allocation observation is the most important factor in TMDLs system. Because if load allocation is not observed, it is difficult to achieve water quality goal of unit watershed. Also it is impossible to improve water quality of the drinking water sources. Therefore it is necessary to apply some kind of sanctions (penalty) in case of excess of load allocation. The sanctions have to be, however, applied differently based on various reduction plan types, i.e., using the reduction load planed in 2nd phase, delay the completion, additional reduction in 2nd phase, error of the pollution sources, etc. Moreover, the penalty load should be properly imposed, lest it should be overburden the provence. The reduction load trade inter province must be restrictively permmitted only the same unit watershed.

통합 환경 관리를 위한 수질 환경의 질 목표 수준 설정 방법에 관한 연구 (A study on the method of setting the water quality target level for integrated environmental management)

  • 황현정;간종범;서지혜;이선경;김영란
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.187-196
    • /
    • 2021
  • When evaluating the extent of the impact of water pollutants on the surrounding area, we would like to present the target level (proposal) of the quality of the environment, which is the standard for evaluation. We propose the environmental quality target level for substances that need to be applied domestically by investigating overseas cases operating the integrated environmental management system and the implications of domestic environmental pollutant management. The appropriateness of the environmental quality target level reviewed in this study was determined using data from the water quality measuring network, and future improvement measures were proposed. We review the available methodologies for setting quality objectives for the environment. It proposed the environmental quality target level for 21 substances that have domestic water pollutant emission standards and do not have environmental standards, and proposed future improvement measures. If it is necessary to add quality target-level items of the environment in the future, it is believed that expansion will be possible based on the methodology presented in this study.

환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구 (A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites)

  • 이정주;이주상;김신도
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

풍속과 풍향이 미세먼지농도에 미치는 영향 (Effect on the PM10 Concentration by Wind Velocity and Wind Direction)

  • 채희정
    • 환경위생공학
    • /
    • 제24권3호
    • /
    • pp.37-54
    • /
    • 2009
  • The study has analyzed impacts and intensity of weather that affect $PM_{10}$ concentration based on PM10 forecast conducted by the city of Seoul in order to identify ways to improve the accuracy of PM10 forecast. Variables that influence $PM_{10}$ concentration include not only velocity and direction of the wind and rainfalls, but also those including secondary particulate matter, which were identified to greatly influence the concentration in complicated manner as well. In addition, same variables were found to have different impacts depending on seasons and conditions of other variables. The study found out that improving accuracy of $PM_{10}$ concentration forecast face some limits as it is greatly influenced by the weather. As an estimation, this study assumed that basic research units and artificially estimated pollutant emissions, study on mechanisms of secondary particulate matter productions, observatory compliment, and enhanced forecaster's expertise are needed for better forecast.

다변량 해석기법에 의한 금강 하구역의 수질평가 (Evaluation of Water Quality in the Keum River Estuary by Multivariate Analysis)

  • 김종구
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.591-598
    • /
    • 1998
  • This study was conducted to evaluate water quality in the Keum River estuary using principal component analysis. The results was summarized as follow; Water quality in the Keum River estuary could be explained up to 70.40% by three factors which were included in the inffluent loading by the Keum River and Kyungpo cheon(38.99%), seasonal variation and organic matter pollution(19.05%), sediment resuspension and internal metabolism(12.35%). For spatial variation of factor score, artificial pollutant loading is highest at st.1, below Keum River barrage, and decreases toward the outer sea. For annual variation of factor score, factor 1 was highly related to artificial pollutant leading, and it was gently increased in 1994. Also, organic matter pollution, sediment resuspension and internal metabolism were increased to every year. It is necessary to control the nutrient leading by Keum river and Kyongpo cheon for Water quality management of estuary.

  • PDF

PREDICTION OF COMBINED SEWER OVERFLOWS CHARACTERIZED BY RUNOFF

  • Seo, Jeong-Mi;Cho, Yong-Kyun;Yu, Myong-Jin;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.62-70
    • /
    • 2005
  • Pollution loading of Combined Sewer Overflows (CSOs) is frequently over the capacity of a wastewater treatment plant (WWTP) receiving the water. The objectives of this study are to investigate water quality of CSOs in Anmyun-ueup, Tean province and to apply Storm Water Management Model to predict flow rate and water quality of the CSOs. The capacity of a local WWTP was also estimated according to rainfall duration and intensity. Eleven water quality parameters were analyzed to characterize overflows. SWMM model was applied to predict the flow rate and pollutant load of CSOs during rain event. Overall, profile of the flow and pollutant load predicted by the model well followed the observed data. Based on model prediction and observed data, CSOs frequently occurs in the study area, even with light precipitation or short rainfall duration. Model analysis also indicated that the local WWTP’s capacity was short to cover the CSOs.

수질자료의 불확실성이 수질관리에 미치는 영향 (Impacts of Uncertainty of Water Quality Data on Wate Quality Management)

  • 김건하
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.427-430
    • /
    • 2006
  • Uncertainty is one of the key issues of the water quality management. Uncertainty occurs in the course of all water quality management stages including monitoring, modeling, and regulation enforcement. To reduce uncertainties of water quality monitoring, manualized monitoring methodology should be developed and implemented. In addition, long-term monitoring is essential for acquiring reliable water quality data which enables best water quality management. For the water quality management in the watershed scale, fate of pollutant including its generation, transport and impact should be considered while regarding each stage of water quality management as an unit process. Uncertainties of each stage of water quality management should be treated properly to prevent error propagation transferred to the next stage of management for successful achievement of water quality conservation.

한강수계 의무적 수질오염총량관리제시행지원을 위한 조사·연구의 우선순위 설정 (Research Priorities to Support Mandatory Implementation of a Total Pollutant Load Management System (TPLMS) in the Han River Basin)

  • 이창희;이범연;이수웅
    • 환경정책연구
    • /
    • 제8권4호
    • /
    • pp.25-36
    • /
    • 2009
  • 지금까지 한강수계에서 임의적으로 시행되던 수질오염총량관리제도가 의무적 시행으로 전환될 예정이다. 본 연구에서는 갭분석과 계층화분석 등의 객관적인 접근을 통해 이러한 의무적 시행을 지원할 수 있는 조사 연구 방향 및 우선순위를 제시하였다. 갭분석 결과 아직까지 우리나라의 총량관리는 새로운 제도를 정착시키기 위한 규제에 초점을 두는 제도시행의 초기적 특성을 보이고 있어, 향후에는 배출권거래의 도입, 배출허가시스템의 개선 등 시행의 유연성 및 실효성을 제고하는 제도개선 분야에 대한 조사 연구가 필요한 것으로 나타났다. 계층화분석 결과를 보면 특정분야보다는 제도개선 및 과학적 불확실성 해소를 위해 전 분야의 조사 연구가 병행될 필요가 있는 것으로 나타나 아직 제도의 시행이 안정화 단계에 이르고 있지 못함을 반영하고 있다. 세부분야 별 조사 연구의 필요성은 목표수질 설정의 타당성 확보가 가장 큰 것으로, 기술적 측면에서는 부하량 및 수질예측 모델의 신뢰성 제고 및 획기적인 부하량 및 삭감방안의 개발이 강조되어야 할 것으로 나타났다.

  • PDF

화학산업의 환경친화적 경영에 관한 고찰: 다우케미컬사의 환경경영 사례를 중심으로 (A Study ong the Environmental Management in Chemical Industry: with Relation to Dow Chemical's Environmental Management)

  • 김현수;박영태
    • 품질경영학회지
    • /
    • 제28권2호
    • /
    • pp.192-210
    • /
    • 2000
  • Chemical industry has contributed significantly to the enhancement of quality of human life, but it has been regarded as a major area of environmental problem due to the potential hazards in environment and safety. This paper examines environmental management programs of chemical industry such as RC(Responsible Care) and PRTR(Pollutant Release and Transfer Register). Through the survey of Dow Chernical's environmental management system, it is examined in detail how a leading company in chemical industry has coped with environmental problem companywide.

  • PDF

GIS를 이용한 하천수질관리 (An Application of GIS to Water Quality Management)

  • 양형재;이유원;김민
    • 환경영향평가
    • /
    • 제3권2호
    • /
    • pp.25-32
    • /
    • 1994
  • This study was carried out as the Anyang creek water quality management using Geographic Information System (GIS) is the purpose of this pilot project to apply a GIS to environmental management field. Analysis of water quality data has been investigated using GIS with modeling of water quality management for the Anyang creek. The results of this study are summarized as follows: 1. The concentration of Mercury in sediment was increased rapidly nearby A26(Nightsoil Treatment Plant) and maximum was showed at A18 (Imgok bridge). Cadmium was increased rapidly at A35(Chulsan bridge). 2. River water quality management using visible computer system as GIS is effective to make decision for water quality management plan and database of environmental factors should be completed before applying GIS. 3. When water pollution accident is occurred in the river water system, pollutant source can be traced and analysed systematically using GIS to manage pollutants discharged into the river water system.

  • PDF