• Title/Summary/Keyword: PM_{2.5}$

Search Result 17,614, Processing Time 0.039 seconds

Characteristics of Water Soluble Ions in Fine Particles during the Winter and Spring in Daegu (대구지역 겨울철과 봄철 미세먼지의 수용성 이온성분 특성)

  • Park, Ji-Yeon;Lim, Ho-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.627-641
    • /
    • 2006
  • Atmospheric $PM_{2.5}$ and $PM_{10}$ were measured to investigate their levels and water-soluble ions(${SO_4}^{2-},\;{NO_3}^-,\;{NO_2}^-,\;Cl^-,\;{NH_4}^+,\;Na^+,\;Ca^{2+},\;Mg^{2+},\;and\;K^+$) in Daegu between February 17 and April 18, 2006. Four Asian dust episodes during the period were examined for the influence of Asian dust on the particulate properties. Daily $PM_{2.5}\;and\;PM_{2.5-10}$ concentrations ranged between $10.83{\sim}136.76{\mu}g/m^3$ with a mean of $38.43{\mu}g/m^3$ and $16.13{\sim}409.13{\mu}g/m^3$ with a mean of $79.98{\mu}g/m^3$, respectively. For all measured ions the mean fractions of $PM_{2.5}\;and\;PM_{2.5-10}$ were 51.8% and 28.9% being lowered to 30.7% and 9.4%, respectively, during the dust episodes. Secondary ions (i.e., non-sea salt ${SO_4}^{2-},\;{NO_3}^-,\;and\;{NH_4}^+$) contributed 44.3% and 14.8% to $PM_{2.5}\;and\;PM_{2.5-10}$, respectively, with a decreased contribution during the episodes. The average equivalent ratio of ${NH_4}^+$ to the sum of ${SO_4}^{2-}\;and\;{NO_3}^-$ was 0.99 and 0.89 for $PM_{2.5}\;and\;PM_{2.5-10}$, respectively, indicating high source strength of $NH_3$ and its dominance in the neutralization of the acidic ions. Correlations and charge balance between ions suggest that neutralization of the acidic ions results in substantial depletions of carbonate both in $PM_{2.5}\;and\;PM_{2.5-10}$ and chloride only in $PM_{2.5}$.

Analysis of PM2.5 Pattern Considering Land Use Types and Meteorological Factors - Focused on Changwon National Industrial Complex - (토지이용 유형과 기상 요인을 고려한 PM2.5 발생 패턴 분석 - 창원국가산업단지를 중심으로 -)

  • SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.2
    • /
    • pp.1-17
    • /
    • 2022
  • This study analyzed the PM2.5 pattern by using data measured for one year from June 2020 to May 2021 by 21 low-cost sensors installed near the Changwon National Industrial Complex in Changwon, Gyeongsangnam-do. For the PM2.5 pattern, the land use types around the measuring points and meteorological factors such as air temperature and wind speed were considered. The PM2.5 concentration was high from November to March in winter, and from 1 to 9 in the morning and early in the morning by time zone. The concentration of PM2.5 was higher as it got closer to the industrial area, but the concentration was lower in the residential area and public facility area. In terms of meteorological factors, the higher the air temperature and wind speed, the lower the concentration of PM2.5. As a result of this study, it was possible to identify the PM2.5 patter near Changwon National Industrial Complex. This result will be useful data that can be used in urban and environmental planning to improve air quality including PM2.5 in urban area in the future.

Using visibility to estimate PM2.5 concentration trends in Seoul and Chuncheon from 1982 to 2014 (시정을 이용하여 추정한 1982~2014년 서울과 춘천의 PM2.5 농도 변화 추이)

  • Lee, Yong-Hee;Kwak, Kyung-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.156-165
    • /
    • 2018
  • Long-term trend analysis on air pollutant concentrations is very important to diagnose the present status and plan for the future. In this study, the long-term trends of $PM_{2.5}$ concentrations were estimated based on the relationship between the visibility and $PM_{2.5}$ concentration regarding the effects of relative humidity in Seoul and Chuncheon. The relationships between the visibility and $PM_{2.5}$ concentration were derived from the measurement data in 2015 and 2016. Then, the annual trends of $PM_{2.5}$ concentration from 1982 to 2014 were estimated and compared to those of $PM_{10}$ concentration available in Seoul and Chuncheon. During the estimation process, four ranges of relative humidity were considered such as less than 30%, 31~50%, 51~70%, and 71~90%. In Seoul and Chuncheon, the visibility and $PM_{2.5}$ concentration generally have the inverse relationship while the visibility decreases as the relative humidity increases. The estimated $PM_{2.5}$ concentrations similarly showed the decreasing tendencies from 2006 to 2012 in Seoul and Chuncheon. However, the estimated $PM_{2.5}$ concentrations showed the increasing tendency before 2005 in Chuncheon in contrast to the decreasing tendency in Seoul. This implies that the long-term trends of $PM_{2.5}$ concentration in different cities in South Korea reflect the local influencing factors. For example, 'Special Act on the Improvement of Atmospheric Environment in the Seoul Metropolitan Area' can affect the different long-term trends in Seoul and Chuncheon. The estimated $PM_{2.5}$ concentrations were validated with the measured ones in Seoul and Chuncheon. While the general tendencies were well matched between the estimated and measured concentrations, the $PM_{2.5}$ concentration trends in 1990s and their monthly variations are needed to be improved quantitatively using more reference data for longer years.

Polysomnographic Results before and after Uvulopalatopharyngoplasty

  • Kim, Cheon-Sik;Kim, Dae-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Pae, Sang-Ho;Kim, Won-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.2
    • /
    • pp.73-76
    • /
    • 2013
  • Uvulopalatopharyngoplasty (UPPP) is one possibility for the treatment of Obstructive Sleep Apnea (OSA). The aim of this study was study the analysis of polysomnography of pre-UPPP and post-UPPP. All patients were evaluated by means of a physical examination, the epworth sleepiness scale (ESS), the beck depression inventory (BDI) and the nocturnal polysomnography (PSG) before surgery, and 6~12 months after surgery. A total of 15 patients were investigated. All underwent UPPP. The patients were between 26 and 62 years old ($mean{\pm}SD$; $39.7{\pm}10.9$) with a lean body mass index (BMI) of $mean{\pm}SD$; $26.2{\pm}3.0kg/m^2$. The comparison of sleep questionnaires showed that after UPPP, the patients had a significantly lower BMI ($26.2{\pm}3.0kg/m^2$ vs $26.0{\pm}3.4kg/m^2$, p=0.241), ESS ($10.0{\pm}5.4$ vs $6.9{\pm}3.2$, p=0.022), BDI ($9.2{\pm}8.2$ vs $4.2{\pm}4.3$, p=0.343) and higher blood pressure ($127.5{\pm}12.1$ vs $123.7{\pm}12.0$, p=0.272) compared to before UPPP. The comparison of sleep parameters showed that after UPPP, patients had a significantly lower stage N1 ($108.8{\pm}53.1$ vs $82.2{\pm}48.9$, p=0.016), lower sleep latency ($4.9{\pm}4.4$ vs $2.0{\pm}1.7$, p=0.083), a lower total arousal number ($210.6{\pm}90.3$ vs $147.1{\pm}87.3$, p=0.019), lower oxygen desaturation index (ODI) ($30.2{\pm}20.9$ vs $10.2{\pm}15.1$, p=0.006), lower apnea-hypopnea index (AHI) ($31.6{\pm}22.4$ vs $10.9{\pm}15.4$, p=0.005), and a lower respiratory disturbance index (RDI) ($37.4{\pm}21.3$ vs $18.5{\pm}16.5$, p=0.008) compared to after UPPP. The comparison of sleep parameters showed that after UPPP, patients had a significantly higher stage N2 ($154.0{\pm}39.9$ vs $180.5{\pm}49.5$, p=0.017), higher REM ($58.5{\pm}29.7$ vs $72.6{\pm}34.0$, p=0.249), higher $meanSaO_2$ ($94.3{\pm}2.0$ vs $95.9{\pm}0.9$, p=0.043), and higher $meanSaO_2$ ($79.3{\pm}8.5$ vs $83.1{\pm}7.9$, p=0.116) than before UPPP. After UPPP, 6 patients were cured, 2 showed marked improvement, and 7 did not improve. After surgery, the success of the treatment was at 53%. The subjective patient satisfaction was higher than before the surgery.

  • PDF

Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea (서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증)

  • Han, Bangwoo;Hong, Keejung;Shin, Dongho;Kim, Hakjoon;Kim, Yongjin;Kim, Sangbok;Kim, Sangwoo;Hwang, Cheongha;Noh, Kwangchul
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.

Characteristics of Fine Particles at Roadside and Urban Residential Locations in Busan (부산지역 도로변과 주거지역의 PM10과 PM2.5 농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.577-586
    • /
    • 2018
  • This research investigated the characteristics of $PM_{10}$ and $PM_{2.5}$ concentration at roadside (Choryangdong) and residential (Sujeongdong) locations in Busan. The $PM_{10}$ concentration at roadside and residential locations were 50.5 and $42.9{\mu}g/m^3$, respectively, and $PM_{2.5}$ at roadside and residential were 28.1 and $23.9{\mu}g/m^3$, respectively. The roadside/residential ratio of $PM_{10}$ and $PM_{2.5}$ concentration were 1.18, and the $PM_{2.5}/PM_{10}$ ratio at roadside and residential were 0.55 and 0.56, respectively. The $PM_{10}$ concentration in spring at roadside were $64.6{\mu}g/m^3$, and were the highest, followed by $48.0{\mu}g/m^3$ and $45.2{\mu}g/m^3$ in winter and summer. Number of exceedances per year of the daily limit value for $PM_{10}$ at roadside and residential were 66 and 39 days, respectively. The $PM_{10}$ and $PM_{2.5}$ concentration, and $PM_{2.5}/PM_{10}$ ratio at roadside were $53.0{\mu}g/m^3$, $29.0{\mu}g/m^3$ and 0.55 for day, and $45.5{\mu}g/m^3$, $26.7{\mu}g/m^3$ and 0.59 for night, respectively. These results indicate that understanding the relationship between roadside and residential could provide insight into establishing a strategy to control urban air quality.

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Investigational Studies on Reproductive Failures of Slaughtered Cows (도살빈우의 번식장애사례 조사연구)

  • 이용빈;임경순
    • Korean Journal of Animal Reproduction
    • /
    • v.6 no.1
    • /
    • pp.19-30
    • /
    • 1982
  • 1. The cows slaughtered at age of 3, 4, 6, 7, 8, and 9 years old were 1.5, 1.5, 15.0, 62.5 and 4.4% respectively. 2. The cows slaughtered at 351-450kg and more than 500kg were 60 and 28% respectively. 3. Best, very good, good and bad cows in nutritional condition were 1.6, 25.8, 62.9, and 9.7% respectively. Among the six cows which were bad nutrition, the two were with severe endometritis, the three were normal in genital function and one was on 70 days of pregnancy. 4. Holstein cows(55.2%) showed higher reproductive failure than the Korean cows(33.3%). 5. The slaughted ratio of the Korean cattle and Holstein cows was 36 and 64% respectively. 6. Pregnant cows were about 16% among the slaughtered one. 7. Reproductive failures were composed of 46% in uterus, 32% in ovaries, 8% in udder, 6% in oviduct, 4% in cervix of uterine, 2% in vagina and 2% inmummified fetus. 8. Forty six percentages of uterine diseases were as follows; horn, 13%, body of uterus, 32% and ovary diseases were 32%, that is, 12% of ovary atrophy, 8% of ovarycyst and 6% of lutealcyst. 9. The cows of reproductive failures were commonly infected with 1.6 kinds of diseases. 10. According to classification, six type of ovaries were as follows; normal, 58%, ovary-cyst, 11%, luteum cyst, 4%, coexistence of follicles and corpus luteum, 16%, weak function of ovaries, 10% and ovarian atrophy, 1%. 11. Major axis, minor axis and thickness of right ovary were larger than those of left one both in Korean cattle and Holstein cows. Holstein cow had generally larger size of ovary than these of the Korean cattle.. 12. The left and right oviducts showed no difference in length, but Holstein had longer oviduct than Korean cow. 13. There was no difference in the length of uterine horn between right and left in the Korean cows, but the right was longer than the left in Holstein cows. 14. Holstein had longer horn and body of uterine than the Korean cows. 15. The weight of right ovary was heavier than that of left in both breeds, but there was no differences in weight of left ovary between two breeds and right ovary of Holstein breed was heavier than that of the Korean cow. 16. The weight of right oviduct and uterine born was heavier than that of the left, and Holstein had heavier oviducts and uterine horns than the Korean cows. 17. Holstein had heavier uterine body and cervix of uterine than the Korean cows. 18. The length of reproductive systems of Korean cow is as follows; Major and minor diameter and thickness ofovary are 3.6${\pm}$0.7, 2.3${\pm}$0.4 and 1.6${\pm}$1.4 cm in left and 3.7${\pm}$0.6, 2.5${\pm}$0.5 and 1.8${\pm}$0.5 cm in right. Oviduct is 28.4${\pm}$3.1 cm in left and 27.8${\pm}$3.3 cm in right. Uterine horn is 27.4${\pm}$4.5 cm in left and 27.7${\pm}$4.9 cm in right. Uterine body and cervix are 3.4${\pm}$1.1 and 6.5${\pm}$1.7 cm. 19. The length of female reproductive systems ofHolstein cow is as follows; Major and minor diameter and thickness of ovary are 3.9${\pm}$1.3, 2.3${\pm}$0.5, and 1.5${\pm}$0.6 cm in left and 4.0${\pm}$0.8, 2.8${\pm}$0.6 and 1.8${\pm}$0.6 cm in right. Oviduct is 29.4${\pm}$4.2 cm in left and 29.3${\pm}$4.1 cm in right. Uterine horn is 30.2${\pm}$7.4 cm in left and 32.6${\pm}$8.4 cm in right. Uterine body and cervix are 4.5${\pm}$2.5 and 7.8${\pm}$2.9 cm. 20. The weight of reproductive systems of Korean cow is as follows; Ovary is 8.4${\pm}$4.1 g in left and 9.3${\pm}$3.6g in right. Oviduct is 1.5${\pm}$0.5 g in left and 1.6${\pm}$0.5 g in right. Uterine horn is 109${\pm}$27 g left and 118${\pm}$32 g in right. Uterine body and cervix are 30.4${\pm}$14.1 and 76.7${\pm}$38.4g. 21. The weight of reproductive systems of Holstein cow is as follows; Ovary is 8.2${\pm}$3.1 g in left and 12.5${\pm}$5.6 g in right. Oviduct is 1.7${\pm}$0.6 g in left and 1.9${\pm}$0.9 g in right. Uterine horn is 199${\pm}$14.2 g in left and 221${\pm}$111.2g in right. Uterine body and cervix are 58.2${\pm}$46.5 and 126.7${\pm}$103.3 g.

  • PDF

Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area (익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성)

  • Kang, Gong-Unn;Kim, Nam-Song;Kim, Kyung-Suk;Kim, Mi-Kyung;Lee, Hyun-Ju
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.

Analysis of Meteorological Factors when Fine Particulate Matters Deteriorate in Urban Areas of Jeju Special Self-Governing Province (제주특별자치도 도시지역 미세먼지 악화 시 기상요소 분석)

  • Sin, Jihwan;Jo, Sangman;Park, Sookuk
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.36-58
    • /
    • 2022
  • In this study, the weather conditions corresponding to the increase in the environmental concentration of fine dust (PM10) and ultrafine dust (PM2.5) from 2001 to 2019 in Jeju and Seogwipo cities were analyzed. The increase in the levels of PM10 and PM2.5 was observed in the order: spring > winter > autumn > summer. In both cities, PM10 and PM2.5 levels increased more frequently during the day in spring and summer and at night in autumn and winter, with PM2.5 showing a greater increase in concentration than PM10. The air temperature and wind speed corresponding with increased levels of PM10 were higher than their respective seasonal averages in spring and winter, but lower in summer and autumn. Relative humidity was lower than the seasonal average during all seasons. The air temperature variation corresponding with increased levels of PM2.5 showed the same seasonal trend as that observed for PM10. The relative humidity was higher than the respective seasonal averages in spring and summer, and lower in winter. The wind speed was lower than the seasonal average in both the cities. When the PM10 and PM2.5 levels increased, the wind direction was from the north and the west during the day and varied according to the season at night. The rate of the increase in the PM10 concentration was the highest in both cities at the wind speed of 1.6 - 3.4 ms-1 during the day and night except during night in the summer. The highest concentration of PM2.5 was observed with the wind speed range of 1.6 - 3.4 ms-1 in Jeju, and 0.3 - 1.6 ms-1 in Seogwipo. The results of this study applied to urban and landscape planning will aid in the formulation of strategies to reduce the adverse effects of fine particular matter.