• Title/Summary/Keyword: PMV 모델

Search Result 8, Processing Time 0.026 seconds

A Study on the Application of Simulation-based Simplified PMV Regression Model for Indoor Thermal Comfort Control (실내 온열환경 쾌적 제어를 위한 단순 PMV 회귀모델의 적용에 관한 시뮬레이션 연구)

  • Kim, Sang-Hun;Yun, Sung-Jun;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2015
  • The PMV regression analysis was conducted for this model based on a database of the PMV variables. PMV regression model simplification was completed through sensitivity and data analysis. The simplified PMV regression model's and Fanger PMV model was confirmed through MAE and RMSE. And the EMS in EnergyPlus was used to establish a simplified PMV regression analysis-based thermal comfort control. Also, the thermal comfort controls based on simplified PMV model and the Fanger PMV model were applied to the building model, it was confirmed that both controls met the thermal comfort range in more than 90% of cases during the air conditioning period.

Simplification of PMV through Multiple Regression Analysis (다중회귀분석을 통한 PMV 모델의 단순화)

  • Moon, Yong-Jun;Noh, Kwang-Chul;Oh, Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.761-769
    • /
    • 2007
  • The purpose of this study is to present a simplified model of predicted mean vote (PMV) using multiple regression analysis. We performed the experiments and the numerical calculations in the lecture room during summer and winter to simplify PMV. And the multiple regression analysis on PMV was conducted to estimate the contribution of independent variables toward PMV. From the multiple regression analysis, we found that the effect of independent variables on PMV followed in order, clo value>air temperatur>air velocity>mean radiant temperature>relative humidity. And the simplified PMV was proposed through a few assumptions and then was compared with original PMV. They had a good agreement with each other. Additionally, we compared the simplified PMV with EDT. We expected that the simplified PMV can be more useful than EDT to evaluate the thermal comfort in the place, where radiation is dominant. But the comfort range of the simplified PMV should be adjusted to predict the exact thermal comfort in the future.

Multicast Model and Application of Group Communication System using Trigger (트리거를 이용한 그룹통신시스템의 멀티캐스트모델 및 응용)

  • Ryu Kwon-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1222-1228
    • /
    • 2006
  • In this paper, I propose a video watermaking method using adaptive threshold value and half-cell motion vector. Conventional method cause a lot of change of motion vectors and bring about a falling-off in invisibility, because it search embedding condition about whole macroblocks and watermarks are embedded in arbitrary motion vectors. Proposed method improve invisibility and decrease in number of change of motion vectors, because it create threshold value by using power of motion vector(PMV), and watermarks are embedded in motion vectors which greater than threshold value. Consequently, proposed method improve invisibility with on an average 5.4 dB ~9.3dB according to video bit-stream.

Development of Air Quality Assessment Model for Subway Cabin (도시철도 객실 공기질 평가모델 개발)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Kim, Se-Young;Park, Jae-Hyung;Cho, Goan-Hyun;Yoo, Gun-Jong;Kim, Jung-Su
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF

A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC (HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구)

  • Yoon, Seong Hyun;Park, Jun Yong;Son, Deok Young;Choi, Yunho;Park, Kyungseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.979-988
    • /
    • 2014
  • Recently, the interest in the thermal comfort is ever increasing as the time people stay in the automobile is gradually increasing. So far, however, the cooling performance of the HVAC(heating and ventilation air conditioning) system is evaluated by thermal environment criteria such as indoor air velocity and temperature, not by a thermal comfort index. Furthermore, the precise criteria has not been established yet when the thermal comfort for the automobile is evaluated using numerical analysis. In this study, the numerical analysis of automobile indoor thermal comfort according to various parameters such as HVAC operating mode, airflow, passenger boarding conditions is performed during the HVAC system's initial operating time(20 minutes). The solar ray tracing model and S2S radiation model are used and validated to simulate an external heat source. Based on this study, an evaluation model which can predict the thermal comfort index for the combination of the above parameters is presented.

Evaluation of Thermal Comfort and Cooldown Performance inside Automotive Cabin according to Air-conditioning Vent Location (인체모델을 고려한 자동차 실내의 에어컨 토출구 위치 변화에 따른 냉방성능 및 온열쾌적성 평가)

  • Seo, Jin-Won;Park, Jae-Hong;Choi, Yun-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.120-129
    • /
    • 2012
  • As the recent advancement of automobile industry, there has been a great interest in the thermal comfort of the passengers inside the cabin of an automobile. Thermal comfort is affected by temperature, velocities, and mean radiation temperature of air, thermal resistance of clothes and physical active level of human. The present study performed computational analysis to select the location of air-conditioning vent that improves thermal comfort inside the cabin. In order to do this, we considered various air vent positions, and thermal flow analysis of each case is performed using CFD for the cabin with four passengers. The thermal comfort is evaluated using the computational results and the optimum location of air vent is suggested.

Proxy-Quorum Based Replication Control Schemes for Mobile Internet Systems (이동형 인터넷 기기를 위한 위임 정족수 기반의 복제데이터 제어 기법)

  • Byun Si-Woo
    • Journal of Internet Computing and Services
    • /
    • v.5 no.1
    • /
    • pp.51-57
    • /
    • 2004
  • Mobile Internet allows users to request critical information and receive swift responses at any places, but mobile users could suffer from unreliable and ill-timed services due to the characteristics of wireless media, One way that reduces possibility of the unsatisfactory services is data replication. Data Replica1ion, however, inevitably induces the overhead of maintaining replica consistency which requires more expensive synchronization mechanism. We propose a new replicated data management scheme in distributed mobile environment, In order to alleviate negative impact of synchronization message overhead in fault-prone mobile Internet environment, we devise a new replication control scheme called proxy quorum consensus (PQC), PQC minimizes the message overhead by coordinating quorum access activities by means of proxy mediated voting (PMV) which exploits reliable proxy hosts instead of unreliable mobile hosts in voting process, We also propose a simulation model to show the performance of PQC. Based on the results of the performance evaluation, we conclude that PQC scheme outperforms the traditional schemes.

  • PDF

A Design Model Development for Street-Oriented Block Housing Reducing Urban Heat Island Effects (도시 열섬 완화를 위한 가로형 집합주택 계획모델 연구)

  • Kim, Ho-Jeong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.6
    • /
    • pp.27-37
    • /
    • 2019
  • This study focused on the possibility of reducing the cooling load through the change of micro climate in the outdoor space during summer season. This study proposes an efficient planning model by comparing the effects of urban heat island mitigation through wind path planning, outdoor space vegetation, and exterior material change by using the basic model of the street-oriented block housing proposed in the previous research by the same author. As a result, the most effective wind path planning strategy in the street-oriented block housing was the change of the air flow through the mass height adjustment. When the tall building masses were staggered and arranged in a balanced manner, the overall wind environment could be improved. The greater the height difference between low and high masses, the better the air flow was shown. It was also important to arrange the building masses so that the inlet of the main wind was open and to allow the external space to connect to the adjacent block to create a continuous flow. The change of outdoor space vegetation and flooring, and the formation of wind paths through the opening of lower part also showed the effect of heat island reduction. In addition, the change of PMV in summer was the biggest influence of shadow by tall building mass. Attention should be paid to the fact that high-albedo exterior materials are adversely affected by multiple reflections in dense street-oriented block housing. The use of albedo of the exterior material showed that it is necessary to pay attention to apply in the high density block housing. This is attributed to the rise of the temperature due to the absorption of energy into the low-albedo flooring, where the high-albedo exterior causes multiple reflections.