• Title/Summary/Keyword: PMSG(Permanent Magnet Synchronous Generator)

Search Result 88, Processing Time 0.027 seconds

Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage (배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가)

  • Kim, Hyun-Jun;Kim, Do-Hyun;Kim, Kyung-Tae;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.

Design and optimization of 900kW class PMSG, based on Unison U50 model (Unison U50 직접구동 영구자석 발전기를 기반으로 한 900kW급 동기발전기 설계 및 최적화)

  • Kim, Tae-Hun;Lee, Sang-Woo;Kim, Dong-Eon;Chung, Chin-Wha;Park, H.C.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.423-426
    • /
    • 2009
  • POSTECH Graduate School of Wind Energy is trying to upgrade the PMSG used for Unison U50 to 900 kW class. Intensive optimization efforts are carried out the reduce the axial size and total weight of the generator while increasing the rated output to 900 kW. The generator features 3.32m stator inner radius, 671mm stator length, 84 pole, 25 rated rpm and 31.6kN/$m^2$ shear force density. To reduce the gross weight, the stronger magnetic material is applied with optimal magnet size resulting lowest cogging torque. Also, instead of stator skewing the stator, the magnet position along the circumference is optimized to further reduce the cogging torque. This scheme eliminates the stator skewing procedure and may enhance the productivity. This method also reduces the total harmonic distortion. In this report, upgrade method, no-load line to line voltage and phase voltage, cogging torque, loss calculations and thermal analysis are presented.

  • PDF

Characteristic Analysis of Stand-Alone Microgrid with PMSG-Based Wind Turbine (PMSG 기반 풍력발전기가 연계된 독립형 마이크로그리드의 계통 특성 분석)

  • Yoo, Jae-Ik;Kim, Jae-Woo;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.509-510
    • /
    • 2015
  • 본 논문에서는 강인한 계통과 연계되어 있지 않은 독립형 마이크로그리드에 PMSG (Permanent Magnet Synchronous Generator)기반 풍력발전기를 연계하였을 때의 계통 특성을 분석한다. 독립형 마이크로그리드에서는 계통과 연계되어 있지 않기 때문에 하나의 분산전원이 기준전원으로 동작하여 전압과 주파수를 유지하고 나머지 분산전원이 전력흐름에 따라 전류제어를 수행하여야 한다. 인버터 기반의 전원을 기준전원으로 설정하고 PMSG 기반 풍력발전기를 연계하였을 시 컨버터의 전압 제어 및 정격출력보다 큰 출력이 나올 경우 피치각 제어를 통한 출력 특성과 제어기의 성능을 검증한다.

  • PDF

Estimating PMSG Wind Turbines by Inertia and Droop Control Schemes with Intelligent Fuzzy Controller in Indian Development

  • Josephine, R.L.;Suja, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1196-1201
    • /
    • 2014
  • This paper presents an exploration on the effect of wind turbine contribution to the frequency control of individual systems that can be used for efficient power production in India. The research includes the study of Permanent Magnet Synchronous Generator (PMSG), in wind farms. The WTs are tested for inertia and for droop responses with intelligent fuzzy logic controllers (FLC) that choose Double Input Single Output (DISO) strategy that automatically sets gain constants, as well as combined responses for the WTs. Quantitative analyses are presented for the WTs for benefits and drawbacks including appropriate selection parameters. The analysis includes inertia, droop and combined inertia, droop schemes. The reconnaissance also incorporates inertia with FLC, droop with FLC, inertia and droop with FLC schemes for detailed study of WTs, so as to forecast and achieve proper frequency control. Moreover, the analysis provides the best suited method for frequency control in PMSG.

A Study on the Eddy Current Loss of the Permanent Magnet for PMSG for the Wind Turbine Application (풍력터빈 적용을 위한 PMSG용 영구자석의 와전류손실에 관한 연구)

  • Choi, Man-Soo;Moon, Chae-Joo;Sun, Rui;Chang, Young-Hak;Park, Tae-Sik;Jeong, Moon-Seon;Kwak, Seung-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.8-15
    • /
    • 2014
  • The objective of this paper is to suggest a design topology of permanent magnet synchronous generator with 2,000kW capacities for wind turbine. The suggested topology is to provide 3 split magnet PMSG instead of single magnet, and performed an analysis of eddy current loss and iron loss for suggested type using ansoft maxwell commercial program. The simulation results of suggested magnet type show there duction of eddy current loss as 13.87kW with loadless conditions and23.48kW with rated conditions, but iron loss for rotor yoke show the in creasing trend as2.2kW with loadless conditions and 0.2kW with rated conditions. The suggested 3 split maget type is to identified as more useful for 2,000kW PMSG.

Renewable Energy Configuration Plan of Micro Grid in Gapa Island (가파도 마이크로그리드 신재생 에너지 전원 구성 방안)

  • Kim, Dong-Wan;Ko, Ji-Han;Kim, Seong Hyun;Kim, Homin;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.16-23
    • /
    • 2014
  • This paper presents a renewable energy configuration plan of Micro grid in Gapa Island. To analyze the characteristics of Micro grid, BESS (Battery Energy Storage System), PMSG (Permanent Magnet Synchronous Generator) and SCIG (Squirrel Cage Induction Generator) are first modelled. The PMSG and SCIG will operate with basis on the real power curve. when the total power demand is larger than the total power generation, the BESS will be operated and the SOC (State Of Charge) is reduced. If the value of SOC could drop down to limited value, the system may be broken because of the voltage drop of BESS. To solve this problem, a DG (Diesel Generator) is used to charge the BESS and keep the voltage value of BESS with in a allowance limit. This paper represents simulation result when PMSG, SCIG connected to the Micro grid installed in Gapa Island. The simulation is carry out by using PSCAD/EMTDC program with actual line constant and transformer parameter in Gapa Island.

Virtual Inertia Control of D-PMSG Based on the Principle of Active Disturbance Rejection Control

  • Shi, Qiaoming;Wang, Gang;Fu, Lijun;Liu, Yang;Wu, You;Xu, Li
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.1969-1982
    • /
    • 2015
  • The virtual inertia control (VIC) of wind turbine with directly-driven permanent-magnet synchronous generator (D-PMSG) can act similarly to the conventional synchronous generator in inertia response and frequency control, thereby supporting the system frequency stability. However, because the wind speed is inconstant and changeable to a certain extent and the D-PMSG is a complex nonlinear system, there are great difficulties in the virtual inertia optimal control of the D-PMSG. Based on the design principle of the active disturbance rejection control (ADRC), this paper presents a new VIC strategy for the D-PMSG from the perspective of power disturbance suppression in the system. The strategy helps fulfill the power grid disturbance estimation and compensation by means of the extended state observer (ESO) so as to improve the disturbance-resisting performance of the system. Compared with conventional proportional-derivative virtual inertia control (PDVIC), this method, which is of better adaptability and robustness, can not only improve the property of the D-PMSG responding to the system frequency but also reduce the influence of wind speed disturbance. The simulation and experiment results have verified the effectiveness and feasibility of the VIC based on the ADRC.

Sensorless MPPT Control for a Small-scale Wind Power Generation System with a Switched-mode Rectifier(SMR) (SMR을 갖는 소형풍력발전시스템의 센서리스 MPPT제어)

  • Xu, Chengde;Lee, Joon-Min;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1688-1693
    • /
    • 2013
  • A small-scale wind power generation system with a switched-mode rectifier(SMR) is proposed. To simplify the converter circuit of the wind power generation system, the synchronous inductors of the permanent magnet synchronous generator(PMSG) replace the inductor for the boost converter. The sensorless maximum power point tracking(MPPT) control is carried out for the wind power generation system with the SMR. The proposed system is verified through the simulations and the experiments.

Power Fluctuation Reduction of Pitch-Regulated MW-Class PMSG based WTG System by Controlling Kinetic Energy

  • Howlader, Abdul Motin;Urasaki, Naomitsu;Yona, Atsushi;Senjyu, Tomonobu;Saber, Ahmed Yousuf
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.116-124
    • /
    • 2012
  • Wind is an abundant source of natural energy which can be utilized to generate power. Wind velocity does not remain constant, and as a result the output power of wind turbine generators (WTGs) fluctuates. To reduce the fluctuation, different approaches are already being proposed, such as energy storage devices, electric double layer capacitors, flywheels, and so on. These methods are effective but require a significant extra cost to installation and maintenance. This paper proposes to reduce output power fluctuation by controlling kinetic energy of a WTG system. A MW-class pitch-regulated permanent magnet synchronous generator (PMSG) is introduced to apply a power fluctuation reducing method. The major advantage of this proposed method is that, an additional energy storage system is not required to control the power fluctuation. Additionally, the proposed method can mitigate shaft stress of a WTG system. Which is reflected in an enhanced reliability of the wind turbine. Moreover, the proposed method can be changed to the maximum power point tracking (MPPT) control method by adjusting an averaging time. The proposed power smoothing control is compared with the MPPT control method and verified by using the MATLAB SIMULINK environment.

Design and Experimental Validation of a Digital Predictive Controller for Variable-Speed Wind Turbine Systems

  • Babes, Badreddine;Rahmani, Lazhar;Chaoui, Abdelmadjid;Hamouda, Noureddine
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.232-241
    • /
    • 2017
  • Advanced control algorithms must be used to make wind power generation truly cost effective and reliable. In this study, we develop a new and simple control scheme that employs model predictive control (MPC), which is used in permanent magnet synchronous generators and grid-connected inverters. The proposed control law is based on two points, namely, MPC-based torque-current control loop is used for the generator-side converter to reach the maximum power point of the wind turbine, and MPC-based direct power control loop is used for the grid-side converter to satisfy the grid code and help improve system stability. Moreover, a simple prediction scheme is developed for the direct-drive wind energy conversion system (WECS) to reduce the computation burden for real-time applications. A small-scale WECS laboratory prototype is built and evaluated to verify the validity of the developed control methods. Acceptable results are obtained from the real-time implementation of the proposed MPC methods for WECS.