• Title/Summary/Keyword: PMMA (polymethylmethacrylate)

Search Result 142, Processing Time 0.022 seconds

Color alterations of a PMMA resin for fixed interim prostheses reinforced with silica nanoparticles

  • Kotanidis, Alexandros;Kontonasaki, Eleana;Koidis, Petros
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.4
    • /
    • pp.193-201
    • /
    • 2019
  • PURPOSE. The aim of the present study was to evaluate the color changes of an autopolymerizing PMMA resin used for interim fixed restorations, reinforced with $SiO_2$ nanoparticles. MATERIALS AND METHODS. Silica nanoparticles were blended with the PMMA resin powder through high-energy ball milling. Four shades of PMMA resin were used (A3, B3, C3, D3) and total color differences were calculated through the equations ${\Delta}E_{ab}=[({\Delta}L*)^2+({\Delta}a*)^2+({\Delta}b*)^2]^{1/2}$ and ${\Delta}E_{00}=[(\frac{{\Delta}L^{\prime}}{K_LS_L})^2+(\frac{{\Delta}C^{\prime}}{K_CS_C})^2+(\frac{{\Delta}H^{\prime}}{K_HS_H})^2+R_T(\frac{{\Delta}C^{\prime}}{K_CS_C})(\frac{{\Delta}H^{\prime}}{K_HS_H})]^{1/2}$. Statistically significant differences between ${\Delta}E_{ab}$ and the clinically acceptable values of 3.3 and 2.7 and those between ${\Delta}E_{00}$ and the clinically acceptable value of 1.8 were evaluated with one sample t-test (P<.05). Differences among the different shades were assessed through One-Way ANOVA and Bonferroni multiple comparison tests. RESULTS. Significantly lower values were detected for all groups concerning ${\Delta}E_{ab}$ compared to the intraorally clinical acceptable values of 3.3 and 2.7. Significantly lower mean values were detected for groups B3, C3, and D3, concerning ${\Delta}E_{00}$ compared to the intraorally clinical acceptant value of 1.8. Color pigments in red-brown (A3) and red-grey (D3) shades affect the total color change to a greater extent after the reinforcement with $SiO_2$ nanoparticles compared to the red-yellow (B3) shade. CONCLUSION. Within the limitations of this in vitro study, it can be suggested that reinforcing PMMA with $SiO_2$ nanoparticles at 0.25 wt% slightly affects the optical properties of the PMMA resin without being clinically perceivable.

Micro Structure Fabrication Using Injection Molding Method (인젝션 몰딩 기술을 이용한 마이크로 구조물 성형)

  • Je T. J.;Shin B. S.;Chung S. W.;Cho J. W.;Park S. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.253-259
    • /
    • 2002
  • Micro cell structures with high aspect ratio were fabricated by injection molding method. The mold inserts had dimension $1.9cm\times8.3cm$ composed of a lot of micro posts and were fabricated by LIGA process. The size of the micro posts was $157{\mu}m\times157{\mu}m\times500{\mu}m$ and the gaps between two adjacent posts were $50{\mu}m$. Using Polymethylmethacrylate (PMMA) injection molding was performed. The key experimental variables were temperature, pressure, and time. By controlling these, good shaped mim cell structures with $50{\mu}m$ in wall thickness and $500{\mu}m$ in depth were obtained. In order to understand micro molding mechanism, shape changes of molded PMMA were studied with experimental variables. And the durability of mold insert was investigated, too. The results show that the most important factor in molding processes was the mold temperature that is closely related to the filling of the melt into the micro cavity. And the holding time before cooling showed a great effect on the quality of molded PMMA.

  • PDF

Repeat Vertebroplasty for the Subsequent Refracture of Procedured Vertebra

  • Choi, Sang Sik;Hur, Won Seok;Lee, Jae Jin;Oh, Seok Kyeong;Lee, Mi Kyoung
    • The Korean Journal of Pain
    • /
    • v.26 no.1
    • /
    • pp.94-97
    • /
    • 2013
  • Vertebroplasty (VP) can effectively treat pain and immobility caused by vertebral compression fracture. Because of complications such as extravasation of bone cement (polymethylmethacrylate, PMMA) and adjacent vertebral fractures, some practitioners prefer to inject a small volume of PMMA. In that case, however, insufficient augmentation or a subsequent refracture of the treated vertebrae can occur. A 65-year-old woman visited our clinic complaining of unrelieved severe low back and bilateral flank pain even after she had undergone VP on the $1^{st}$ and $4^{th}$ (L1 and L4) lumbar vertebrae a month earlier. Radiologic findings showed the refracture of L1. We successfully performed the repeat VP by filling the vertebra with a sufficient volume of PMMA, and no complications occurred. The patient's pain and immobility resolved completely three days after the procedure and she remained symptom-free a month later. In conclusion, VP with small volume cement impaction may fail to relieve fracture-induced symptoms, and the refracture of an augmented vertebral body may occur. In this case, repeat VP can effectively resolve both the persistent symptoms and problems of new onset resulting from refracture of the augmented vertebral body due to insufficient volume of bone cement.

Fabrication and Characterization of Film Type Light Guide Plates by UV Imprint Lithography (UV 임프린팅법에 의한 필름형 광도광판의 제조 및 특성 연구)

  • Kim, Hyeong-Gwan;Kim, So-Won;Lee, Hee-Chul
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.2
    • /
    • pp.178-185
    • /
    • 2016
  • In this study, we have fabricated light guide plates (LGPs) in thin film form for edge type back light unit (BLU) by using UV imprint lithography. In the LGPs, the pattern of functional resins on PC and PMMA substrates were successfully transferred from original master mold through PVC stamp. Optimized pattern arrays with slowly-sloped density were designed to obtain high brightness and uniformity. We could obtain a relatively improved brightness of $950cd/m^2$ and a uniformity of 87.3% by using the NP-S20 functional resins at an input power of 1.3 W because NP-S20 resin could show high formability after UV hardening process. The LGP prepared on polymethylmethacrylate (PMMA) substrate exhibited higher brightness than that on polycarbonate (PC) substrate because PMMA has lower refractive index resulting in more refraction toward the vertical direction.

A study on Creep of Plate PMMA in Thermal-Nanoindentation Process for Hyperfine pit structure Fabrication (극미세 점 구조체 제작을 위한 열간나노압입 공정에서의 평판형 PMMA의 크립현상에 관한 연구)

  • Lee, E.K.;Jung, Y.N.;Kang, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.273-276
    • /
    • 2008
  • Thermoplastic resin takes place stress relaxation and creep according to temperature and time. In room temperature, time dependent deformation (TDD) of polymer was carried out at previous study. In this study, it evaluates time dependent deformation to relate temperature. Nanoscale indents can be used as cells for molecular electronics and drug delivery, slots for integration into nanodevices, and defects for tailoring the structure and properties. Therefore, it is important to control pattern depth for change of indent depth by creep when using Nanoindenter. For evaluating TDD at high temperature, it is occurred thermal-nanoindentation test by changing hold time at maximum load. Temperature is putted at $90^{\circ}C$, hold time at maximum loads are putted at 1, 10, 50, 100, 200, 300 and 500s.

  • PDF

Evaluating the absorption loading technique to acrylic resin for drug delivery

  • Al-Kaabi, Arshad F.;Hamid, Mohammed A.
    • Advances in materials Research
    • /
    • v.11 no.2
    • /
    • pp.165-170
    • /
    • 2022
  • Acrylic resin or polymethylmethacrylate (PMMA) is one of the most attractive materials to be used for dental appliances manufacturing. It has been introduced as a biomaterial during the last century. This study aims to evaluate the compounds absorption and release through acrylic resin to be used for drug delivery as well. The study specimens were 10 pieces of heat-cured clear acrylic resin with dimensions of 10 × 10 × 2 mm. The specimens were dipped in methylene blue solution at a powder-water ratio of 1:20 for 5 days. The samples were removed and dipped in 5 ml distilled water vials for 24 hours. Then the specimens were replaced into new 5 ml vials and the process lasted for 4 days. The extracted solutions were analyzed by the visible light spectroscopy for absorbance. The statistical results showed a gradual increase in stain release from day 1 to day 4 with a significant difference between day 1 and day 4 solutions. The study showed that PMMA resin is able to absorb and release some compounds constantly and the absorption drug-loading technique is applicable to this material.

Total Hip Replacement in a Jindo Dog with Dorsal Acetabular Rim Deficiency: a Case Report (등쪽 관골절구 결손을 가진 진도견의 인공 대퇴 관절 전치환술)

  • Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.121-124
    • /
    • 2014
  • A 7-year-old, intact female Jindo dog was presented for assessment of weight-bearing lameness of the right hindlimb. On physical examination, crepitus and pain was noted in the right coxofemoral joint upon extension. Radiographs revealed a craniodorsal luxation of the right coxofemoral joint and degenerative joint disease (DJD) of both coxofemoral joints. Total hip replacement (THR) was performed for the right coxofemoral joint. Intraoperatively, dorsal acetabular rim (DAR) deficiency was noted, which can be related to a high risk for acetabular cup implant dislocation. Deficiency of the dorsal acetabular rim realigned with the acetabular cup using universal locking plate (ULP) and polymethylmethacrylate (PMMA) bone cement. After surgery, the patient had an uneventful course and a successful outcome. The ROM and thigh girth were dramatically improved. There were no complications associated with prosthesis implants. Hip luxation with dorsal acetabular rim deficiency in a dog was successfully repaired with THR and dorsal acetabular rim augmentation using ULP and PMMA bone cement. This technique should be considered when conventional THR is precluded by dorsal acetabular rim deficiency.

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.

Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium

  • Alfouzan, Afnan Fouzan;Alotiabi, Hadeel Minife;Labban, Nawaf;Al-Otaibi, Hanan Nejer;Taweel, Sara Mohammad Al;AlShehri, Huda Ahmed
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.160-171
    • /
    • 2021
  • Purpose. This in-vitro study evaluated and compared the color stability of 3D-printed and conventional heat-polymerized acrylic resins following aging, mechanical brushing, and immersion in staining medium. Materials and methods. Forty disc-shaped specimens (10 mm in diameter and 3 mm thick) were prepared from two 3D-printed [DentaBASE (DB) and Denture 3D+ (D3D)] and one conventional polymethylmethacrylate (PMMA) denture materials. The specimens were thermo-cycled, subjected to mechanical brushing, and were immersed in either coffee, lemon juice, coke, or artificial saliva (AS) to simulate one and two years of oral use. Color measurements of the specimens were recorded by a spectrophotometer at baseline (T0), and after one (T1) and two years (T2) of simulation. The color changes (ΔE) were determined and also quantified according to the National Bureau of Standards (NBS) units. Descriptive statistics, followed by factorial ANOVA and Bonferroni post-hoc test (α=.05), were applied for data analysis. Results. The independent factors, namely material, staining medium, and immersion time, and interaction among these factors significantly influenced ΔE (P<.009). Irrespective of the materials, treatments, and time, the highest and the lowest mean ΔEs were observed for PMMA in lemon juice (4.58 ± 1.30) and DB in AS (0.41 ± 0.18), respectively. Regarding the material type, PMMA demonstrated the highest mean ΔE (2.31 ± 1.37), followed by D3D (1.67 ± 0.66), and DB (0.85 ± 0.52), and the difference in ΔE between the materials were statistically significant (P<.001). All the specimens demonstrated a decreased color changes at T2 compared to T1, and this difference in mean ΔE was statistically significant (P<.001). Conclusion. The color changes of 3D-printed denture resins were low compared to conventional heat polymerized PMMA. All the tested materials, irrespective of the staining medium used, demonstrated a significant decrease in ΔE values over time.

DBR PSi/Polymer Composite Materials -Dual Photonic Characteristics (DBR 다공성 실리콘/고분자 Composite 재료-이중적 광학특성)

  • Park, Cheol-Young;Jang, Seung-Hyun;Kim, Ji-Hoon;Park, Jae-Hyun;Koh, Young-Dae;Kim, Sung-Jin;Ko, Young-Chun;Sohn, Hong-Lae
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.221-226
    • /
    • 2007
  • DBR (distributed Bragg reflectors) PSi (porous silicon) composite films displaying dual optical properties, both optical reflectivity and photoluminescence had been developed. DBR PSi samples were prepared by electrochemical etch of heavily doped $p^{++}-type$ silicon wafers (boron doped, polished on the <100> face, resistivity of $0.8-1.2m{\Omega}-cm$, Siltronix, Inc.). Free-standing DBR PSi films were treated with PMMA (polymethyl methacrylate) to produce flexible, stable composite materials in which the PSi matrix is covered with PMMA containing photoluminescent polysiloles. Optical characteristics of DBR PSi/polysilole-impregnated PMMA composite materials exhibit both their photonic reflectivity at 565 nm and photoluminescence at 510 nm, simultaneously. A possible application of this materials will be discussed.