• Title/Summary/Keyword: PM2-Continuous Model

Search Result 41, Processing Time 0.034 seconds

Reliability Growth Planning for a Military System Using PM2-Continuous Model (예측방법론 기반 연속형 계획 모델을 적용한 무기체계의 신뢰도 성장 계획)

  • Seo, Yangwoo;Park, Eunshim;Kim, Youngkuk;Lee, Kwanyoung;Kim, Myungsoo
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.201-207
    • /
    • 2018
  • Purpose: To develop the reliability growth planning for a subsystem of guided weapon system using PM2-Continuous model. Methods: The target MTBF of the subsystem is set by allocating the system target MTBF to the lower level, where ARINC method is applied. Other model parameters such as initial MTBF, management strategy ratio and average fix effectiveness factor are chosen from historical growth parameter estimates. Given the values of model parameters, the reliability growth planning curve using PM2-Continuous model is constructed and the sensitivity analyses are performed for the changes of model parameters. Results: We have developed the reliability growth plan for a subsystem of guided weapon system using PM2-Continuous model. It was found that the smaller the ratio of initial MTBF to target MTBF, the smaller the management strategy ratio, the smaller the average fix effectiveness factor, and the shorter the development test period, the higher reliability growth is required. Conclusion: The result of this study will be used as a basis for establishing the reliability growth plan, the test period setting and the budget appropriation for the similar system entering the system development stage in the future.

EEG Patterns of High dose Pilocarpine-Induced Status Epilepticus in Rats (흰쥐에서 고용량의 Pilocarpine에 의하여 유발된 간질중첩증의 양상)

  • Lee, Kyung-Mok;Jung, Ki-Young;Kim, Jae-Moon
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.2
    • /
    • pp.119-124
    • /
    • 2000
  • Background : We studied EEG changes during pilocarpine-induced status epilepticus(SE), a widely used model whose EEG characteristics have not been fully described previously. Methods : Male Sprague-Dawley rats weighing 250-350 grams were used as subjects. SE was induced 5-7 days after placement of chronic epidural electrodes, using 360-380 mg/Kg pilocarpine IP. Rats were observed with continuous EEG recording following pilocarpine injection until end of the SE episode. Results : SE occurred in 10/12 rats studied. SE began with a series of discrete seizures $11.1{\pm}3.93$ minutes after pilocarpine injection. $5.2{\pm}2.71$ seizures occurred over $10.9{\pm}4.62$ minutes, until the EEG converted to a waxing and waning pattern, during which the amplitude and frequency of epileptiform activity increased. After $1.4{\pm}1.82$ minutes, a pattern of continuous high amplitude rapid spiking was established. Continuous spiking continued for $3.4{\pm}0.48$ hours with a very gradual decline in amplitude and frequency, until periodic epileptiform discharges(PEDs) began to occur. The EEG consisted primarily of PEDs for another $7.4{\pm}3.09$ hours, until electrographic generalized seizures began to occur. These continued for $5.8{\pm}4.82$ hours until death. Duration of SE was $17.0{\pm}5.88$ hours. Flat periods were a prominent feature during all EEG patterns in this model. Conclusion : EEG features distinctive in pilocarpine SE(but not unique to it) include flat periods during all patterns and resumption of continuous spiking episodes after the onset of PEDs. The sequence of discrete seizures to waxing and waning to continuous spiking to PEDs was identical to that which has been described in humans and other animal models.

  • PDF

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

ANALYSIS OF TEMPERATURE RISE ON THE ROOT SURFACE DURING CONTINUOUS WAVE OF CONDENSATION TECHNIQUE (Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석)

  • Kim, Young-Ju;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.341-347
    • /
    • 2003
  • This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed $130.82{\pm}2.96^{\circ}C,{\;}158.00{\pm}5.26^{\circ}C,{\;}215.92{\pm}6.91^{\circ}C{\;}and{\;}249.88{\pm}3.65^{\circ}C$ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.0l). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was $2.37{\pm}0.09^{\circ}C{\;}at{\;}150^{\circ}C{\;}setting,{\;}3.11{\pm}0.12^{\circ}C{\;}at{\;}200^{\circ}{\;}setting,{\;}3.93{\pm}0.09^{\circ}C{\;}at{\;}250^{\circ}C{\;}setting{\;}and{\;}5.69{\pm}0.15^{\circ}C{\;}at{\;}300^{\circ}C$ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings on digital temperature display of System B HeatSource.

Emission Characteristics of Elemental Constituents in Fine Particulate Matter Using a Semi-continuous Measurement System (준 실시간 측정시스템을 이용한 미세입자 원소성분 배출특성 조사)

  • Park, Seung-Shik;Ondov, John M.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.190-201
    • /
    • 2010
  • Fine particulate matter < $1.8{\mu}m$ was collected as a slurry using the Semicontinuous Elements in Aerosol Sampler with time resolution of 30-min between May 23 and 27, 2002 at the Sydney Supersite, Florida, USA. Concentrations of 11 elements, i.e., Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Se, and Zn, in the collected slurry samples were determined off-line by simultaneous multi-element graphite furnace atomic absorption spectrometry. Temporal profiles of $SO_2$ and elemental concentrations combined with meteorological parameters such as wind direction and wind speed indicate that some transient events in their concentrations are highly correlated with the periods when the plume from an animal feed supplement processing facility influenced the Sydney sampling site. The peaking concentrations of the elemental species during the transient events varied clearly as the plume intensity varied, but the relative concentrations for As, Cr, Pb, and Zn with respect to Cd showed almost consistent values. During the transient events, metal concentrations increased by factors of >10~100 due to the influence of consistent plumes from an individual stationary source. Also the multi-variate air dispersion receptor model, which was previously developed by Park et al. (2005), was applied to ambient $SO_2$ and 8 elements (Al, As, Cd, Cr, Cu, Fe, Pb, and Zn) measurements between 20:00 May 23 and 09:30 May 24 when winds blew from between 70 and $85^{\circ}$, in which animal feed processing plant is situated, to determine emission and ambient source contributions rates of $SO_2$ and elements from one animal feed processing plant. Agreement between observed and predicted $SO_2$ concentrations was excellent (R of 0.99; and their ratio, $1.09{\pm}0.35$) when one emission source was used in the model. Average ratios of observed and predicted concentrations for As, Cd, Cr, Pb, and Zn varied from $0.83{\pm}0.26$ for Pb to $1.12{\pm}0.53$ for Cd.

Long-Range Transport Characteristics of Air Masses in Taean, Korea Using A Lagrangian Trajectory Model and Cluster Analysis Technique Part 2. Chemical Compounds Characteristics of $PM_{2.5}$ Particle Related to Long-Range Transport Patterns

  • Zhuanshi He;Kim, Young-Joon;Hong, Chun-Sang
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.193-194
    • /
    • 2000
  • To investigate the characteristics of fine particles and the relationships between pollutant concentrations and long-range transport patterns in Asia area, continuous every 6-day sampling (case 1) and an intensive field sampling (case 2) had been carried out between March 1998 and July 1999 at Taean, Korea. Anionic ($Cl^{-}$, ${NO_{3}}^{-}$, ${SO_{4}}^{2-}$) and Cationic ($Na^+$, ${NH_{4}}^{ +}, $K^+$, $Mg^{2+}$, $Ca^{2+}$) concentrations of $PM_{2.5}$ particle were analyzed. The major objective of this study is to investigate the relationships between the chemical compounds of $PM_{2.5}$ and the long-range transport patterns during intensive sampling period.

  • PDF

A fuzzy model of human performance for VDU workers (VDU작업자의 작업수행도에 대한 퍼지모형)

  • ;;;神代雅晴
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.97-104
    • /
    • 1995
  • The widespread use of VDU has improved the efficiency of information transmission between man and machine, but has caused new occupational health and ergonomics problems. In this study, we tried to construct a fuzzy hyman performance model of VDU workers in Korea. Fuzzy inferences of human perfor- mance are obtained from the fuzzy inference rule with the job difficulty, CFF, SACL, Type A. and the degree of concentration in VDU work. Eight healthy female undergraduate students at Kyungnam university for subjects aged 20 to 23 years were examined in this experiment. They calculated continuous addition, subtraction, and multiplication of 1 or 2 digit numbers that were produced randomly on the CRT. Subjects peoformed two types of a numeric operation, which easy and difficult work produced 400 and 600 problems within a 40 minute work session, respectively. Subjects were tested over two workdays according to the type of work(easy and difficult) consisting of four 40 minutes work sessions in the morning. Each work lasted for five minutes with a ten minutes rest break. 117 fuzzy inference rules were obtained from the experimental data. The value of consequent part was obtained by a descent method. The difference between real human error and estimated value of fuzzy inference was $1.8075{\pm}1.8591%(M{\pm}SD)$. The difference in easy and diffcult works were $2.69{\pm}2.13%$ and $0.92{\pm}0.93%$, respectively.

  • PDF

The Characteristics and Seasonal Variations of OC and EC for PM2.5 in Seoul Metropolitan Area in 2014 (서울지역의 PM2.5 중 OC와 EC의 특성 및 계절적 변화에 관한 연구)

  • Park, Jong Sung;Song, In Ho;Park, Seung Myung;Shin, Hyejung;Hong, Youdeog
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.6
    • /
    • pp.578-592
    • /
    • 2015
  • To investigate characteristics and seasonal variations of carbonaceous species for $PM_{2.5}$ in Seoul metropolitan area, Korea, we measured organic carbon (OC) and elemental carbon (EC) from January 2014 to December 2014 using a semi-continuous OC/EC Analyzer (Model-4, Sunset Lab.). Mean concentrations of OC and EC were estimated $4.1{\pm}2.7{\mu}g/m^3$ and $1.6{\pm}1.0{\mu}g/m^3$, respectively. The annual averaged OC/EC ratio was $2.9{\pm}2.7$. Concentrations of OC and EC comprised 13% and 5% of $PM_{2.5}$ and the mass fraction of both was the highest in fall. OC and EC showed similar trend in seasonal variations. Concentrations of those showed a clear seasonal variation with the highest in winter and the lowest in summer. The correlations between the two were the best during the winter ($r^2=0.88$). As results of carbonaceous species analysis, the dominant factor in view of fine particle ($PM_{2.5}$) is primary emission source such as mobile, fossil fuel combustion during commute time(08:00~10:00 or 17:00~21:00) and winter season. Continuous monitoring of atmospheric carbonaceous species is essential to provide the science-based data to policy-maker establishing the air quality improvement policy.

Exponent Study of the p($2{\times}1$) Phase on an O/W(110) Surface (O/W(110) 표면의 p($2{\times}1$) 구조의 임계지수 연구)

  • 백두현;정석민;정진욱
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.88-95
    • /
    • 1992
  • Abstract-Using a high resolution low energy electron diffraction(HRLEED), we report an exponent study of 2d continuous phase transition from an ordered ~ ( 2 x 1 )ox ygen overlayer on a W(110) surface. Temperature dependence of a (% 0) superlattice diffraction spot, characteristic of the p(2X 1) structure, shows power-law like divergence of the susceptibility and the fluctuation correlation length at T,=708.765 K. By fitting the intensities as well as the line-shapes, we obtained exponents P=0.19* 0.05, y=1.48+ 0.34, v= 1.23i 0.27 and q=0.38+ 0.12. The non-universal character of the exponents are understood in terms of a 2d XY model with cubic anisotropy as suggested previously.

  • PDF

Semi-continuous Measurements of PM2.5 OC and EC at Gosan: Seasonal Variations and Characteristics of High-concentration Episodes (준실시간 연속관측을 통한 제주 고산 PM2.5 OC와 EC의 계절별 사례별 특성)

  • Han, Jihyun;Bahng, Byungjo;Lee, Meehye;Yoon, Soon-Chang;Kim, Sang-Woo;Chang, Limseok;Kang, Kyeong-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.237-250
    • /
    • 2013
  • At Gosan ABC superstation in Jeju Island, we measured organic carbon (OC) and elemental carbon (EC) in $PM_{2.5}$ from October 2009 to June 2010 using a Sunset Laboratory Model-4 Semi-Continuous OC/EC Field Analyzer. It employs TOT (Thermal-Optical-Transmittance) method with NIOSH 5040 protocol and enables to continuously monitor OC and EC concentrations with 1-hour time resolution. The mean values of OC and EC for the entire period of measurements were $2.1{\pm}1.4{\mu}g/m^3$ and $0.7{\pm}0.6{\mu}g/m^3$, respectively. The OC/EC ratio was 3 and EC accounted $25{\pm}2.1%$ of total carbon (TC, TC=OC+EC). Although OC and EC showed similar trend in seasonal variation, the ratio of OC to EC was the highest in early summer when temperature was the highest and the air was affected by biomass burning in the southern part of China. In winter, the high OC and EC concentrations were likely influenced by increased coal combustion from residential heating. The high OC and EC concentrations were observed during events such as haze, dust, and the combination of the two. During the haze events, OC and EC were enhanced with increase in $PM_{10}$, $PM_{2.5}$, $SO_2$, and $NO_2$ with broad maxima. When dust occurred, both OC and EC started decreasing after reaching their maxima a couple of hours before $PM_{10}$ maximum. The peak separation of carbonaceous species and aerosol masses with time was more noticeable when haze event was followed by dust plume. These results confirm that OC and EC are key components of haze occurring in the study region.