• 제목/요약/키워드: PM10 Flow

검색결과 844건 처리시간 0.03초

음성검사 중 공기역학적 검사에서 한국인의 정상 평균치 (Mean Value of Aerodynamic Study in Normal Korean)

  • 서장수;송시연;권오철;김준우;이희경;정옥란
    • 대한후두음성언어의학회지
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 1997
  • Recently, many people suffering from voice color change visit otolaryngologist. There is no specific data which can be evaluated objectively for voice color change in korean. In aerodynamic study, maximum phonation time, mean air flow rate, phonatory flow volume and subglottal pressure were tested by using Aerophone II voice function analyzer in korean. 112 male and 122 female aged from 10 to 69 years were randomly selected. Maximum phonation time was 20.8${\pm}$6.4sec in male and 17.2${\pm}$4.1sec in female. Mean air flow rate was 167.1${\pm}$61.4ml/sec. in male and 129.6${\pm}$49.3ml/sec in female. Phonatory flow volume was 3184.5${\pm}$646.0ml in male and 2122.1${\pm}$670.5ml in female. Subglottal pressure was 4.1${\pm}$1.8 cmH2O in male and 3.5${\pm}$1.4cm $H_2O$ in female. There was no statistically significant difference among age groups in all above results.

  • PDF

위상대조도 자기공명영상을 이용한 심장 혈류평가에 있어서 호흡정지 기법과 비 호흡정지 기법의 비교평가 (The Assessment of the Breath Hold and the Free Breath Methods about the Blood Flow Evaluation by Using Phase Contrast MRI)

  • 김성호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.149-156
    • /
    • 2016
  • 자기공명영상을 이용한 심장혈류의 측정은 호흡과 심장의 불수의적인 움직임으로 인해 제한되어 왔다. 따라서 본 연구에서는 심장혈류의 측정값을 비교하여 적절한 호흡방법과 영상변수를 제시하고 위상대조도 자기공명영상을 통한 심장혈류검사의 정확성을 향상시키고자 하였다. 연구 대상자는 정상의 지원자 15명(남: 10명, 여: 5명) 평균연령: $30{\pm}5.2$세를 대상으로 하였다. 상행대동맥과 하행대동맥에서 위상대조도 자기공명영상을 이용하여 각각 호흡정지 retrospective 1NEX와 비 호흡정지 retrospective 1-3NEX로 검사하여 비교하여 평가하였다. 연구 결과 상행대동맥에서 호흡정지 retrospective 1NEX의 평균혈류량/평균혈류속도는 각각 $96.17{\pm}19.12ml/sec$, $17.04{\pm}4.12cm/sec$로 비 호흡정지 retrospective 1NEX의 $72.31{\pm}13.27ml$, $12.32{\pm}3.85cm/sec$와는 통계적으로 유의한 차이를 보였다(p<0.05). 반면에 2NEX에서는 평균혈류량과 평균혈류속도가 $101.90{\pm}24.09$, 16.84{\pm}4.32, 3NEX에서는 $103.06{\pm}25.49$, $16.88{\pm}4.19$로 통계적으로 유의한 차이를 보이지 않았다(p>0.05). 하행대동맥에서 호흡정지 retrospective 1NEX의 평균혈류량/평균혈류속도는 $76.68{\pm}19.72ml/sec$, $22.23{\pm}4.8cm/sec$로 비 호흡정지 retrospective 1-3NEX와 비교 시 유의한 차이를 보이지 않았다. 그러므로 비 호흡정지 retrospective방법은 NEX의 증가에 따라 호흡정지 retrospective방법과 비교하여 심장혈류 측정값에 유의한 차이점이 없기 때문에 숨을 잘 참지 못하거나 또는 소아환자에게 있어서 심장혈류 검사의 진단적 가치를 높여줄 것으로 사료된다.

미세먼지 필터 성능향상을 위한 primitive 구조의 유동 제어 연구 (Study on Flow Control of Primitive Structures for Enhancing Particulate Matter Filter Performance)

  • 이종배;황승현;김지연;김현;안동규;정성용
    • 소성∙가공
    • /
    • 제33권4호
    • /
    • pp.270-276
    • /
    • 2024
  • In order to improve the performance of the PM (Particulate Matter) filter, the TPMS structure was used as a flow controller to control the flow entering the filter. Among various TPMS structures, a primitive structure that is easy to utilize 3D printing technique was selected and the effect of unit cell size was analyzed. In addition, numerical analysis was performed and swirl ratio was analyzed to confirm changes in filter inlet flow characteristics that affect changes in filter performance. Unit cell size is closely related to filter performance, and both PM collection efficiency and pressure drop increase as unit cell size decreases. Through quality factor (QF) comparison, which comprehensively evaluate collection efficiency and pressure drop, it was confirmed that when the unit cell size is 5 mm, PM collection efficiency increases, but the flow controller actually reduces filter performance. QF values are similar for unit cell sizes of 10 and 20 mm, and it is advantageous to select the unit cell size among these two considering collection efficiency and operating costs. The filter's collection performance increases due to the increase in swirl flow caused by the primitive structure, and the filter's collection efficiency increases due to the swirl flow that increases throughout the flow field as the unit cell size becomes smaller.

도플러 초음파를 이용한 개의 간혈액량의 측정 (Portal blood flow measurement by doppler ultrasonography in dogs)

  • 성재기;이영원;이희천;안용주;최호정;윤정희
    • 대한수의학회지
    • /
    • 제37권3호
    • /
    • pp.661-668
    • /
    • 1997
  • Portal blood flow was measured with pulsed doppler ultrasound in thirty normal dogs. In normal dogs, the average portal blood flow velocity was $17.03{\pm}1.75cm/sec$ and the average portal blood flow was $41.59{\pm}10.10ml/min/kg$. The incident angle between the doppler beam and the portal vein averaged $65^{\circ}$. The average portal vein sectional area was $0.41{\pm}0.14cm^2$. The Congestion index was $0.0245{\pm}0.0081cm{\cdot}sec$. Conclusively, the spectral doppler ultrasonography was quick, non-invasive and simple diagnostic method in circulatory disorders of liver.

  • PDF

진주시 대기중 PM10 및 PM2.5의 질량농도 특성 (Characterization of PM10 and PM2.5 Mass Concentrations in Jinju)

  • 박정호;박기형;서정민
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.1963-1970
    • /
    • 2014
  • Ambient particulate matters($PM_{10}$ and $PM_{2.5}$) were investigated at GNTECH university in Jinju city. Samples were collected using a dichotomous sampler(series 240, Andersen Corp.) and a TEOM(Tapered Element Oscillating Microbalance) monitor period from November 2012 to October 2013. For the dichotomous sampler measurements, daily 24-h integrated $PM_{2.5}$ and $PM_{10-2.5}$ ambient air samples were collected at a total flow rate of 16.7 L /min. For the TEOM monitor measurements, daily 1-h integrated $PM_{10}$ ambient air samples were collected at a flow rate of 16.7 L /min. The annual average concentrations of $PM_{10-2.5}$ and $PM_{2.5}$ by a dichotomous sampler were $10.0{\pm}6.1{\mu}g/m^3$ and $22.6{\pm}9.3{\mu}g/m^3$, respectively. And $PM_{10}$ concentration by dichotomous sampler were similar to TEOM monitor by $32.7{\pm}12.9{\mu}g/m^3$ and $31.7{\pm}11.3{\mu}g/m^3$, respectively. And good correlation ($R^2=0.964$) between the two methods was observed. The annual average of $PM_{2.5}/PM_{10}$ ratio was $0.70{\pm}0.12$.

타액선 신티그라피를 이용한 정상 타액선기능의 정량분석 (Quantitative Analysis of Normal Salivary Gland Function using Salivary Scintigraphy)

  • 김희진;고명연;박준상
    • Journal of Oral Medicine and Pain
    • /
    • 제25권4호
    • /
    • pp.345-353
    • /
    • 2000
  • This study was to investigate normal salivary flow rates and normal indices of Quantitative analysis of salivary scintigraphy. 96 adult volunteers were studied by Questionnaire evaluating salivary conditions and clinical examinations. 35(male 23, female 12, age range 23-31years) that absented subjective and objective symptoms related saliva were classified as normal group. The normal group underwent measurement unstimulated and stimulated salivary flow rates and salivary scintigraphy. The obtained results were as follows: 1. There were not significant in sex differences of unstimulated and stimulated salivary flow rates. The unstimulated salivary flow rate was $0.66{\pm}0.41g/min$, stimulated salivary flow rates was $1.61{\pm}0.69g/min$. 2. As comparing of parameters of salivary scintigraphy, the Uptake ratio(UR), $T_{max}$, $T_{min}$, Maximum accumulation (MA), Maximum secretion(MS) of parotid and submandibular glands were not significant in sex and side-ralated differences. 3. The UR, $T_{max}$, MA, MS of parotid gland were significantly higher than those of submandibular gland; in the parotid gland, UR, $3.67{\pm}0.88$, $T_{max}$, $18.77{\pm}0.43min$, MA, $41.35{\pm}9.22%$, MS, $43.13{\pm}9.13%$; in the submandibular gland, UR, $3.04{\pm}0.10$, $T_{max}$, $18.48{\pm}0.52min$, MA, $36.47{\pm}14.18%$, MS, $36.88{\pm}12.20%$. 4. As classifying of time-activity curve, the most of parotid gland was N-type(97.1%), submandibular gland was observed in order of M-type(67.1%), N-type(21.4%), F-type(11.4%), however, was not observed S-type. 5. As the type of time-activity curve of submandibular gland was more flattened, the UR, $T_{max}$, MA, MS were significantly decresed.

  • PDF

Effects of Low-Dose Aspirin Therapy on Thermoregulation in Firefighters

  • McEntire, Serina J.;Reis, Steven E.;Suman, Oscar E.;Hostler, David
    • Safety and Health at Work
    • /
    • 제6권3호
    • /
    • pp.256-262
    • /
    • 2015
  • Background: Heart attack is the most common cause of line-of-duty death in the fire service. Daily aspirin therapy is a preventative measure used to reduce the morbidity of heart attacks but may decrease the ability to dissipate heat by reducing skin blood flow. Methods: In this double-blind, placebo-controlled, crossover study, firefighters were randomized to receive 14 days of therapy (81-mg aspirin or placebo) before performing treadmill exercise in thermal-protective clothing in a hot room [$38.8{\pm}2.1^{\circ}C$, $24.9{\pm}9.1%$ relative humidity (RH)]. Three weeks without therapy was provided before crossing to the other arm. Firefighters completed a baseline skin blood-flow assessment via laser Doppler flowmetry; skin was heated to $44^{\circ}C$ to achieve maximal cutaneous vasodilation. Skin blood flow was measured before and after exercise in a hot room, and at 0 minutes, 10 minutes, 20 minutes, and 30 minutes of recovery under temperature conditions ($25.3{\pm}1.2^{\circ}C$, $40.3{\pm}13.7%\;RH$). Platelet clotting time was assessed before drug administration, and before and after exercise. Results: Fifteen firefighters completed the study. Aspirin increased clotting time before and after exercise compared with placebo (p = 0.003). There were no differences in absolute skin blood flow between groups (p = 0.35). Following exercise, cutaneous vascular conductance (CVC) was $85{\pm}42%$ of maximum in the aspirin and $76{\pm}37%$ in the placebo groups. The percentage of maximal CVC did not differ by treatment before or after recovery. Neither maximal core body temperature nor heart rate responses to exercise differed between trials. Conclusion: There were no differences in skin blood flow during uncompensable heat stress following exercise after aspirin or placebo therapy.

20대 여대생을 대상으로 한 치아우식활성검사 연구 (A Study on Dental Caries Activity Test Targeting Female Undergraduates in Their 20s)

  • 윤미숙;윤혜정
    • 치위생과학회지
    • /
    • 제10권6호
    • /
    • pp.465-472
    • /
    • 2010
  • 본 연구에서는 20대 여대생에게 개인에 따라 치아우식증 발생에 작용하는 서로 다른 요인을 찾아내기 위해 치아우식병 발생요인 중 타액요인을 집중적으로 분석하고자 타액분비율, 타액점조도, 타액완충능을 조사하였으며, 치면세균막내 산체류도 치아우식증에 큰 영향을 주기에 치면세균막 수소이온농도를 함께 조사 하여 비교 분석한 결과는 다음과 같다. 다음과 같은 분석결과는 20대 여대생의 치아우식활성검사 결과판독의 기초자료를 제공하고, 치아우식증 발생요인을 규명하는데 기초자료를 제공하고자 실시되었다. 1. 조사 대상자의 평균 우식치아는 1.67개 이었으며, 치아우식으로 인한 발거치아는 0.47개 충전치아는 6.31개로 나타났다. 따라서 평균 영구치우식경험치아는 8.44개로 조사되었다. 2. 치아우식활성검사 방법에 따른 성적으로는 평균 자극성타액분비량은 $12.56{\pm}4.15ml$, 비자극성타액분비량은 $3.89{\pm}1.83ml$, 타액점조도는 $1.49{\pm}0.69$, 타액완충능은 $8.51{\pm}2.44$, 치면세균막 수소이온농도검사는 양치전 $5.62{\pm}0.50$, 양치후 5분 $5.23{\pm}0.58$, 양치후 10분 $5.25{\pm}0.56$, 양치후 15분 $5.29{\pm}0.62$, 양치후 20분 $5.34{\pm}0.58$, 양치후 25분 $5.40{\pm}0.53$, 양치후 30분 $5.61{\pm}0.59$로 나타났다. 3. 자극성타액 및 비자극성타액 분비량, 타액점조도, 타액완충능은 비우식집단이 우식집단 보다 높게 나타났으나, 통계적으로는 유의하지 않았다. 치면세균막 수소이온 농도는 진행 중인 치아우식증이 있는 자와의 관계에서도 전체적으로 통계적인 유의성을 나타내지 않았으나, 비우식집단이 우식집단보다 높게 나타났다. 4. 우식활성검사방법간의 상관관계는 자극성타액분비량은 비자극성 타액분비량과는 유의한 양의 상관이 있었으며(p<0.001), 비자극성타액분비량은 타액완충능과 음의 상관을 나타냈다(p<0.01). 치면세균막 수소이온농도 검사는 양치후 시간이 경과함에 따라 양의 상관을 보였으나, 타액점조도 및 타액완충능과는 유의한 상관이 없었다(p>0.05).

과학기술위성3호 홀 추력 제어기 개발 (Development of a Hall-thruster Propulsion Controller for Science Technology Satellite-3)

  • 이성호;조희근;유준
    • 한국항공우주학회지
    • /
    • 제38권10호
    • /
    • pp.992-997
    • /
    • 2010
  • 과학기술위성3호(STSAT-3)용 홀추력시스템(HPS)의 추력제어모듈(PCM)은 압력정밀도 5%이하와 유량정밀도 3%이하를 목표로 한다. 압력제어기는 비례유량제어밸브(PFCV)와 저압압력센서를 사용하여 목표압력을 제어하도록 하고, 유량제어기는 PFCV와 홀추력기의 에노우드(anode) 전류를 이용하여 유량을 조절한다. 제어형태로는 비례,적분(PI) 제어기를 선택하고, PI 이득은 Matlab 시뮬레이션을 통하여 정한다. 시험결과 압력정밀도 <${\pm}$5%와 유량정밀도 <${\pm}$1.87%를 얻었다. 본 논문은 홀추력 제어모듈의 설계, 구현, 그리고 성능시험 결과를 기술한다.

혈액투석을 위한 동정맥류 조성술후 혈류량과 동정맥루 개존에 관한 임상적 고찰 (Clinical Analysis on Relation Between Blood Flow and Patency af Arteriovenous Fistula for Hemodialysis)

  • 김창회
    • Journal of Chest Surgery
    • /
    • 제24권12호
    • /
    • pp.1167-1172
    • /
    • 1991
  • Since March 1988 we have performed 133 arteriovenous fistulae for hemodialysis in 121 patients with chronic renal failure. Of the 133 cases of arteriovenous fistulae, follow-up evaluation was possible for 80 cases which performed in 69 patients. The relation between blood flow and patency rate and duration of arteriovenous fistula was examined. The overall 6 - 12 - 18 -, and 24 - month patency rates of arteriovenous fistulae were 82%, 64%a, 62%, and 57%, respectively. The maximum blood flow was 150 ~ 350ml /min[mean 217.1$\pm$44.27]. The patency duration was evaluated in patients divided into three groups owing to maximum blood flow through the fistulae. The range of maximum blood flow was 150 ~ 200ml /min for group A, 200 ~ 250ml /min for group B, and above 250ml /min for group C. The mean duration of the patency was 10.7$\pm$7.60 months in group A, 14.9$\pm$9.82 months in group B, and 21.6$\pm$11.16 months in group C[p<0 05]. With increased maximum blood flow, the duration of the patency was longer in group A than group B and C [r=0.39, p<0. 05]. The maintenance blood flow was 100 ~ 250ml /min[mean 179.2$\pm$37.26 ml/min]. When the maintenance blood flow was above 200ml /min, long-term patency rate was higher than the group below 200ml /min[r=0.48, p<0.01]. In the same range of blood flow, patency duration of the patients with using their own blood vessels were longer than the patients with using vascular graft for A-V fistula. We concluded that the patency of the arteriovenous fistulae was closely correlated with the blood flow through the fistulae.

  • PDF