• 제목/요약/키워드: PM10 Air Monitoring

검색결과 304건 처리시간 0.024초

Temporal distribution, influencing factors and pollution sources of urban ambient air quality in Nanchong, China

  • Zhou, Hong;Li, Youping;Liu, Huifang;Fan, Zhongyu;Xia, Jie;Chen, Shanli;Zheng, Yuxiang;Chen, Xiaocui
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.260-267
    • /
    • 2015
  • The $PM_{10}$, $SO_2$ and $NO_2$ mass concentrations were obtained over five years from monitoring stations across Nanchong, a southwest city in China. Changes in urban air quality over time, as well as the factors influencing that change, were evaluated based on air pollutant concentrations, the Air Pollution Index (API), and the Comprehensive Pollution Index (P). The results showed that the total annual mean $PM_{10}$, $SO_2$ and $NO_2$ concentrations over the five years studied were $61.1{\pm}1.1$, $45.0{\pm}3.9$ and $34.9{\pm}4.9{\mu}g{\cdot}m^{-3}$, respectively. The annual mean concentrations displayed a generally decreasing trend; lower than the annual mean second-level air quality limit. Meanwhile, the annual mean API values were in a small range of 52-53, the air quality levels were grade II, and P values were 1.06-1.21 less than the slight level ($P{\leq}1.31$). Total monthly mean $PM_{10}$, $SO_2$, $NO_2$ concentrations, and API and P values were consistently higher in winter and spring than during autumn and summer. The results of a correlation analysis showed that temperature and pressure were the major meteorological factors influencing pollution levels. Pollution sources included industrial coal and straw burning, automobiles exhaust and road dust, fireworks, and dust storms.

Air Quality Monitoring in Residential Areas near Ports and Industrial Complexes in Busan (부산시 항만 및 산단 인근 주거지역 대기질 모니터링과 분기별 특성확인)

  • Hyunji Ju;Seungho Lee;Minjung Kim;Gabeen Lee;Young-Seoub Hong
    • Journal of Environmental Health Sciences
    • /
    • 제50권3호
    • /
    • pp.181-190
    • /
    • 2024
  • Background: Air pollutants have been reported to have harmful effects on human health. Busan is a vulnerable area in terms of air quality due to the installation of various industrial complexes, particularly the port industry. However there is limited research data on the ambient air quality of residential areas near ports and industrial complexes. Objectives: This study aimed to determine the quarterly levels of air pollutants near industrial complexes and ports and to identify trends and characteristics of air pollutant exceedances. Methods: Air measurements were conducted quarterly. The measured air pollutants included O3, SO2, CO, NO2, PM10, and PM2.5. PM10 and PM2.5 were measured using BAM-1020 equipment, while O3, SO2, CO, and NO2 were measured using AP-370 Series equipment. The quarterly concentration levels of air pollutants were determined, and the influence of precipitation and commuting hours on fine particulate matter was examined. Analysis of variance (ANOVA) was conducted to determine if there was significance between the concentrations of fine particulate matter during commuting hours and non-commuting hours. Results: The concentrations of air pollutants were generally higher in the first and second quarters. Furthermore, the concentrations of PM10 and PM2.5 tended to decrease continuously following consecutive rainfall, with concentrations at the end of rainfall periods lower than those observed at the beginning. The frequency of exceeding average concentrations of PM10 and PM2.5 was higher on weekdays. Moreover, the average concentrations of PM10 and PM2.5 during weekday commuting hours were higher compared to non-commuting hours. Conclusions: The concentrations of air pollutants in the survey area were found to be higher than the overall average in Busan. Based on this study, continuous air quality monitoring is necessary for residential areas near industrial complexes and ports. For further research, health biomonitoring of residents in these areas should be conducted to assess their exposure levels.

The Analysis of PM10 Concentration and the Evaluation of Influences by Meteorological Factors in Ambient Air of Daegu Area (대구지역 대기 중 미세먼지의 오염도 분석 및 기상인자에 따른 영향 평가)

  • Hwang, Yoon-Jung;Lee, Soon-Jin;Do, Hwa-Seok;Lee, Yun-Ki;Son, Tae-Jung;Kwon, Taek-Gyu;Han, Jung-Wook;Kang, Dong-Hun;Kim, Jong-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제25권5호
    • /
    • pp.459-471
    • /
    • 2009
  • Air Monitoring Network(11 urban stations) is operated to measure ambient air quality in Daegu city. The urban air monitoring stations include 6 in residence area, 3 in industrial area, 1 in commercial area, and 1 in green area. In this study, hourly data (2006. 1. 1~2008. 12. 31) of $PM_{10}$ were measured at 11 urban air monitoring stations. $PM_{10}$ mean concentrations were high in fall and winter because of low wind speed and many haze days. The number of exceeding the daily standard of $PM_{10}$ in industrial area was approximately twice as many as that in residence area. $PM_{10}$ concentrations and visibility were influenced significantly by wind speed. Wind speed and visibility were below 1.8 m/s and 10 km, respectively when $PM_{10}$ concentrations were over $120{\mu}g/m^3$. $PM_{10}$ concentrations were high when haze was observed. The mean concentrations of $PM_{10}$ were $104{\pm}41.3{\mu}g/m^3$, $63{\pm}35.1{\mu}g/m^3$, and $49{\pm}26.9{\mu}g/m^3$, respectively when haze, mist and clear were observed.

Development of a portable system for monitoring indoor particulate matter concentration (휴대용 실내 미세먼지 농도 측정 장치 개발)

  • Kim, Yoo Jin;Choi, Hyun Seul;Go, Taesik
    • Journal of the Korean Society of Visualization
    • /
    • 제20권1호
    • /
    • pp.45-51
    • /
    • 2022
  • Airborne particulate matter(PM) has been a global environmental problem. PM whose diameter is smaller than 10 ㎛ can permeate respiratory organs and has harmful effects on human health. Therefore, PM monitoring systems are necessary for management of PM and prevention of PM-induced negative effects. Conventional PM monitoring techniques are expensive and cumbersome to handle. In the present study, two types of PM monitoring devices were designed for measuring indoor PM concentration, portably. We experimentally investigated the performance of three commercial PM concentration measurement sensors in a closed test chamber. As a result, PM2008 sensor showed the best PM concentration measurement accuracy. Linear regression method was applied to convert PM concentration value acquired from PM2008 sensor into ground truth value. A mobile application(app.) was also created for users to check the PM concentration, easily. The mobile app. also provides safety alarm when the PM10 concentration exceeds 81 ㎛/m3. The developed hand-held system enables the facile monitoring of surrounding air quality.

Application of MODIS Satellite Observation Data for Air Quality Forecast (MODIS 인공위성 관측 자료를 이용한 대기질 예측 응용)

  • Lee, Kwon-Ho;Lee, Dong-Ha;Kim, Young-Joon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권6호
    • /
    • pp.851-862
    • /
    • 2006
  • Satellites have been valuable tool for global/regional scale atmospheric environment monitoring as well as emission source detection. In this study, we present the results of application of satellite remote sensing data for air quality forecast in Seoul metropolitan area. AOT (Aerosol Optical Thickness) data from TERRA/MODIS (Moderate Resolution Imaging Spectre-radiometer) satellite were compared to ground based $PM_{10}$ mass concentrations, and used to estimate the possibility of the aerosol forecasting in Seoul metropolitan area. Although correlation coefficient (${\sim}0.37$) between MODIS AOT products and surface $PM_{10}$ concentration data was relatively low, there was good correlation between MODIS AOT and surface PM concentration under certain atmospheric conditions, which supports the feasibility of using the high-resolution MODIS AOT for air quality forecasting. The MODIS AOT data with trajectory forecasts also can provide information on aerosol concentration trend. The success rate of the 24 hour aerosol concentration trend forecast result was about 75% in this study. Finally, application of satellite remote sensing data with ground-based air quality observations could provide promising results for air quality monitoring and more exact trend forecast methodology by high resolution satellite data and verification with long term measurement dataset.

Indoor Air Data Meter and Monitoring System (실내 공기 데이터 측정기 및 모니터링 시스템)

  • Jeon, Sungwoo;Lim, Hyunkeun;Park, Soonmo;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제26권1호
    • /
    • pp.140-145
    • /
    • 2022
  • In an advanced modern society, among air pollutants caused by urban industrialization and public transportation, fine dust flows into indoors from the outdoors. The fine dust meter used indoors provides limited information and measures the pollution level differently, so there is a problem that users cannot monitor and monitor the data they want. To solve this problem, in this paper, indoor air quality data fine dust and ultra-fine dust (PM1.0, PM2.5, PM10), VOC (Volatile Organic Compounds) and PIR (Passive Infrared Sensor) are used to measure fine dust. and a monitoring system were designed and implemented. We propose a fine dust meter and monitoring system that is installed in a designated area to measure fine dust in real time, collects, stores, and visualizes data through App Engine of Google Cloud Platform and provides it to users.

Assessing the impact of air pollution on mortality rate from cardiovascular disease in Seoul, Korea

  • Park, Sun Kyoung
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.430-441
    • /
    • 2018
  • The adverse health impact of air pollution is becoming more serious. The purpose of this study is twofold: One is to analyze the effect of air pollution and temperatures on human health by analyzing the number of deaths from cardiovascular disease in Seoul, Korea; the other is to determine what impact the location of a monitoring site has on the results of a health study. For this latter purpose, air pollution and temperature monitors are sited at three locations termed green, public, and residential. Then, a decision tree model is used to analyze factors linked with deaths occurring at each monitoring site. The results show that the environmental temperatures before death and the $PM_{2.5}$ concentrations on the day of death are highly linked with the number of deaths regardless of the monitoring location. However, results are most accurate with residential data. The results of this study can be used as base data for a similar analysis and ultimately, as a guide to minimize the health impact of air pollution.

Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress (도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계)

  • Yang, Seong-Soo;Cho, Sung-Pil;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • 제35권6호
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

Cluster Analysis of PM10 Concentrations from Urban Air Monitoring Network in Korea during 2000 to 2005 (전국 도시대기 측정망의 2000~2005년 PM10 농도 군집분석)

  • Han, Ji-Hyun;Lee, Mee-Hye;Ghim, Young-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권3호
    • /
    • pp.300-309
    • /
    • 2008
  • Variations in PM10 concentration between 2000 and 2005 from 84 urban air monitoring stations operated by the government were analyzed. The K-means cluster analysis was attempted using annual average and the 99th percentile of daily averages as parameters. The results obtained by excluding Asian dust episode days were compared with those obtained by using all available data. In any cases, the cluster with the highest mean concentration was mostly composed of stations in Seoul and Gyeonggi. Annual average of the cluster with the highest mean concentration showed a distinct decreasing trend, but that excluding Asian dust episode days did not show such a trend. Without Asian dust episode days high concentrations of monthly averages in March and April were also not observed. The effect of Asian dust was more pronounced in the 99th percentile of daily averages. The 99th percentile of daily averages of the cluster with the highest mean concentration was the highest in June following downs in April and May.