• Title/Summary/Keyword: PM-10 particle

Search Result 610, Processing Time 0.029 seconds

Design and Performance Evaluation of a Three Stage Impactor (대기 에어로졸 측정용 3단 임팩터의 설계 및 성능평가)

  • 지준호;배귀남;황정호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.6
    • /
    • pp.441-450
    • /
    • 2001
  • A three stage impactor with the cutoff diameters of 1, 2.5, and 10$\mu\textrm{m}$ in aerodynamic diameter was developed and tested. The gravimetric method and the particle counting method were utilized to evaluate the collection performance of each stage. A vibrating orifice aerosol generator was employed to generate monodisperse test aerosols larger that 2$\mu\textrm{m}$ in diameter. Polystyrene latex (PSL) particles smaller than 2$\mu\textrm{m}$ in diameter were generated by an atomizer and the particle number concentration was measured by an Aerodynamic Particle Sizer Spectrometer. The experimental cutoff diameters obtained from the particle collection efficiency curves are in good agreement with the designed values. The square roots of Stokes number at 50% collection efficiency for stage 1, 2, and 3 are 0.42, 0.48, and 0.45, respectively. Effects of the particle bounce and the impaction plate on the collection efficiency were investigated. The collection efficiency curves including effect of the particle bounce were also compared with those of the MOUDI cascade impactor.

  • PDF

Study of Magnetic Filtration for Subway MVAC Dust (지하철 공조실 미세먼지에 대한 자성포집연구)

  • Park, Hae Woo;Chung, Sang Gui;Jo, Young Min
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.37-46
    • /
    • 2015
  • Dust particles, which inflow to the subway mechanical ventilation and air conditioning(MVAC) chamber, contain a fair amount of iron compounds, approximately 25.2w/w%. This work attempted to capture those iron containing dust using magnetic filters. Average magnetization value of the test MVAC dust was 0.012 emu on 5,000 Oe, which could correspond sufficiently with the magnetic interaction. External permanent magnets provided with magnetization of iron mesh screen showing high gradient magnetic field(HGM). It resulted in the capture efficiency with 84.0 ~ 99.7% and 81.2 ~ 99.8% for $PM_{10}$ and $PM_{2.5}$ respectively. Magnetic capture was found to be closely associated with the magnetic intensity, mesh opening size and flow velocity.

ESTIMATION OF RAIN SCAVENGING RATIO FOR PARTICLE BOUND POLYCYCLIC AROMATIC HYDROCARBONS AND POLYCHLORINATED BIPHENYLS

  • Kim, Hyeon-Kook;Shin, Yong-Seung;Lee, Dong-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.33-44
    • /
    • 2006
  • The objective of this study was to develop and assess a method for estimating the rain scavenging ratios (RSRs) of particle-bound PAHs and PCBs using measured scavenging ratio of particulate matters (PM) and routinely available data of physico-chemical properties of PM. Paired atmospheric and rainwater sampling was conducted for a total of 4 rain events. Assuming equilibrium partitioning in rainwater-gas-PM system, an equation was derived for estimating the RSR of particle-bound chemicals as a function of RSR of PM and three equilibrium partition constants (i.e. dimensionless Henry's law constant, gas-particle partition coefficient, and water-particle partition coefficient). For all PAHs, the model significantly under-predicted the RSR while the model prediction for PCBs agreed with observation mostly within a factor of 5. The RSR model for the chemicals is of limited use as its accuracy critically depends on how close the observed partitioning of the chemicals in the gas-PM-rainwater system is to that estimated under the equilibrium assumption.

Real-time High Resolution PM Monitoring in Seoul (서울지역 미세먼지의 실시간 고해상도 모니터링 방안)

  • Kang, Doo Soo;Bong, Choon Keun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

Comparisons of the Particle Emission Characteristics Between GDI and MPI Vehicles (GDI와 MPI 자동차의 미세입자 배출특성 비교)

  • Lee, Jongtae;Kim, Kijoon;Kim, Jeongsoo;Jang, Jihwan;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.182-187
    • /
    • 2014
  • As the regulations for Particulate Matter (PM) and Particle Number (PN) emissions from Gasoline Direct Injection (GDI) Vehicle stringent recently, a lot of studies have been made on the emission characteristics of PM and PN. In this study, PM and PN emission characteristics were compared to GDI and Multi Port Injection (MPI) Vehicles using the Condensation Particle Counter (CPC) measurement equipment. And driving mode is divided into normal driving mode (CVS-75, NEDC, NIER 6, NIER 9) and a constant speed driving mode (10 km/h, 35 km/h, 80 km/h, 110 km/h) to evaluate the characteristics in the various operating conditions. In the results, most of the driving mode, PM and PN were emitted from GDI Vehicle more than MPI Vehicle. However, in the constant speed mode of 110 km/h, PM and PN from MPI Vehicle were also a lot of emission. It is determined to cause a difficulty in the fuel injection control of the MPI Vehicle.

Size Distributions of Atmospheric Particles in Cheonan, Korea

  • Oh, Se-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.45-48
    • /
    • 2006
  • Mass size distributions of atmospheric particles in Cheonan were determined using a high volume air sampler equipped with a 5-stage cascade impactor. Bimodal distributions that are typical for urban atmospheric particles were obtained. A MMD of the fine particle mode was $0.47{\pm}0.05{\mu}m$ with a GSD of $2.72{\pm}0.21$, and those of the coarse particles were $5.15{\pm}0.18{\mu}m\;and\;2.09{\pm}0.09$, respectively. The annual average concentrations of TSP, PM10, PM2.5, and PM1 were 74.1, 67.5, 54.2, and $42.3{\mu}g/m^3$, respectively. Although the daily PM10 concentrations were under the current National Standard, the daily PM2.5 concentrations frequently exceeded the US Standard even in non asian dust periods. The fractions of PM 10, PM2.5, and PM1 in TSP were $0.905{\pm}0.013,\;0.723{\pm}0.022,\;and\;0.572{\pm}0.029$, respectively, and fine mode particles occupied $57{\sim}72%$ of the total particle mass. The results indicate that fine particles were at the concerning level, and should be the target pollutant for the regional air quality strategy in Cheonan.

Laboratory/Field evaluation and calibration method of low-cost PM sensor for indoor PM2.5, PM10 measurement (실내 미세먼지 측정을 위한 저가형 PM 센서의 실험실/현장 평가 및 보정 방법)

  • Doheon, Kim;Dongmin, Shin;Jungho, Hwang
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.109-127
    • /
    • 2022
  • Recently, low-cost particulate matter (PM) sensors have been widely used in monitoring mass concentration. Maintaining the accuracy of the sensors is important and requires rigorous performance evaluation and calibration. In this study, two commercial low-cost PM sensors(LCS), Plantower PMS3003 and Plantower PMS7003, were evaluated in the laboratory and field with a reference-grade PM monitor (GRIMM 11-D). Laboratory evaluation was conducted with single/mixed particles of PSL (Poly Styrene Latex) in an acrylic chamber at 20℃ and relative humidity of 20%. Field evaluation was conducted inside a building of Yonsei University (Shinchon) from February 12 to March 31, 2022. In both evaluations, LCS measured values became different from reference measured values when the relative humidity was high or the outdoor air PM10/PM2.5 ratio was high. Based on the field evaluation, the LCS measured values were corrected through four different regression analysis models. As a result, the multivariate polynomial regression analysis model showed highest matching with the reference PM monitor (PM2.5 >0.9, PM10 >0.85). In this model, the PM10/PM2.5 ratio and relative humidity were chosen as independent variables.

Characteristics of Fine Particle Concentration and Case during Haze Days in Busan (부산 지역 연무 발생일의 미세먼지 농도와 사례별 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.26 no.6
    • /
    • pp.751-765
    • /
    • 2017
  • This research investigates the characteristics of meteorological variation and fine particles ($PM_{10}$ and $PM_{2.5}$) for case related to the haze occurrence (Asian dust, long range transport, stationary) in Busan. Haze occurrence day was 559 days for 20 years (from 1996 to 2015), haze occurrence frequency was 82 days (14.7%) in March, followed by 67 days (12.0%) in February and 56 days (10.0%) in May. Asian dust occurred most frequently in spring and least in winter, whereas haze occurrence frequency was 31.5% in spring, 29.7% in winter, 21.1% in fall, and 17.7% in summer. $PM_{10}$ concentration was highest in the occurrence of Asian dust, followed by haze and haze + mist, whereas $PM_{2.5}$ concentration was highest in the occurrence of haze. These results indicate that understanding the relation between meteorological phenomena and fine particle concentration can provide insight into establishing a strategy to control urban air quality.

Characteristics of Fine Particle Concentration and Ionic Elements of PM2.5 during Sea Breeze Occurrences in Summertime in Busan (부산지역 여름철 해풍 발생 시 미세먼지와 초미세먼지 중의 이온성분 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.30 no.6
    • /
    • pp.465-474
    • /
    • 2021
  • This research investigated the characteristics of fine particle concentration and ionic elements of PM2.5 during sea breeze occurrences during summertime in Busan. The PM10 and PM2.5 concentrations of summertime sea breeze occurrence days in Busan were 46.5 ㎍/m3 and 34.9 ㎍/m3, respectively. The PM10 and PM2.5 concentrations of summertime non-sea breeze occurrence days in Busan were 25.3 ㎍/m3 and 14.3 ㎍/m3, respectively. The PM2.5/PM10 ratios of sea breeze occurrence days and non-sea breeze occurrence days were 0.74 and 0.55, respectively. The SO42-, NH4+, and NO3- concentrations in PM2.5 of sea breeze occurrence days were 9.20 ㎍/m3, 4.26 ㎍/m3, and 3.18 ㎍/m3 respectively. The sulfur oxidation ratio (SOR) and nitrogen oxidation ratio (NOR) of sea breeze occurrence days were 0.33 and 0.05, respectively. These results indicated that understanding the fine particle concentration and ionic elements of PM2.5 during sea breeze summertime conditions can provide insights useful for establishing a control strategy of urban air quality.

An Effectiveness of Simultaneous Measurement of PM10, PM2.5, and PM1.0 Concentrations in Asian Dust and Haze Monitoring

  • Cho, Changbum;Park, Gilun;Kim, Baekjo
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.651-666
    • /
    • 2013
  • This study introduces a novel approach to the differentiation of two phenomena, Asian Dust and haze, which are extremely difficult to distinguish based solely on comparisons of PM10 concentration, through use of the Optical Particle Counter (OPC), which simultaneously generates PM10, PM2.5 and PM1.0 concentration. In the case of Asian Dust, PM10 concentration rose to the exclusion of PM2.5 and PM1.0 concentration. The relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration were below 40%, which is consistent with the conclusion that Asian Dust, as a prime example of the coarse-particle phenomenon, only impacts PM10 concentration, not PM2.5 and PM1.0 concentration. In contrast, PM10, PM2.5 and PM1.0 concentration simultaneously increased with haze. The relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration were generally above 70%. In this case, PM1.0 concentration varies because a haze event consists of secondary aerosol in the fine-mode, and the relative ratios of PM10 and PM2.5 concentration remain intact as these values already subsume PM1.0 concentration. The sequential shift of the peaks in PM10, PM2.5 and PM1.0 concentrations also serve to individually track the transport of coarse-mode versus fine-mode aerosols. The distinction in the relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration in an Asian Dust versus a haze event, when collected on a national or global scale using OPC monitoring networks, provides realistic information on outbreaks and transport of Asian Dust and haze.